1 5 inch pipe tap

    • [DOCX File]VCP shall Home

      https://info.5y1.org/1-5-inch-pipe-tap_1_d0f7df.html

      Where a new pipe clears an existing or new utility by 6" or less, polyethylene plastic foam shall be placed as a cushion between the utilities per Specification 1-07.17(2). Pipe 12" diameter and larger to be abandoned shall be filled with a pumpable, flowable cement slurry. See Specification 2-02.3(5).


    • Standard Construction Contract Documents

      The pitometer tap shall be made at the 12 o'clock position on the water main. Only equipment specially designed for the work shall be used to make the tap. For ductile iron pipe, the tap shall require a full 1 inch drill/tapping tool. For PVC/PVCO pipe, the tap shall require 1-3/8 inch minimum diameter core cutter.


    • [DOCX File]SECTION 05 50 00, METAL FABRICATIONS - Veterans Affairs

      https://info.5y1.org/1-5-inch-pipe-tap_1_fc6144.html

      1.Fabricate from 25 mm (one inch) steel pipe, fasten to steel angles above and extend to a point 150 mm (6 inches) below finished ceiling. ... 5.Drill and tap frames for screw anchors where plate covers occur. ... (1/8 inch) steel, 5 mm (3/16 inch) aluminum or 1 mm (0.0359 inch) thick steel of pan type construction with 25 mm (one inch) of ...



    • [DOC File]OPERATION AND MAINTENANCE MANUAL

      https://info.5y1.org/1-5-inch-pipe-tap_1_7a55c6.html

      5. General System Description. Raw water is supplied to the system by three (3) 300 GPM @ 65 PSI well pumps pumping from 6 inch casings 600 feet deep with 20 feet long 6 inch screens. The pumps are automatically started and stopped by level control on an elevated 150,000 gallons storage tank.


    • League City Building Department

      Water Line Tap Inspection (Line Repair Department: 281-554-1390) Sewer line inspection. 5.1 Provision is made to allow a minimum of 12” of fill over sewer line. 5.2 Sewer is properly sloped and bedded in sand. 5.3 Clean out provided at transition from building drain to building sewer (no more than 3’ away from foundation).


    • [DOC File]GPM/GPH Flow based on PVC Pipe Size

      https://info.5y1.org/1-5-inch-pipe-tap_1_9f7d37.html

      Size (ID, inches) Length (inches) Flow (GPM) 1/2 4.25 26 3/4 4.62 50 1 5.00 94 1-1/2 6.50 260 2 7.00 480 2-1/2 7.50 750 3 8.00 1300 4 9.00 2300 6 15.50 5400 Note: The data is for water through the valve only, and does not take into account the rest of the system.


    • [DOC File]Water System Schematics: Symbols and Examples

      https://info.5y1.org/1-5-inch-pipe-tap_1_ce1cc2.html

      1.5 MG. Res #3. 1.83 MG. Res #2. 0.5 MG. Stoney Mt. Spring Sources (Approx. 9 miles from Res #2) From pump station . to the water . treatment plant 60-inch screening. pump station manhole South Yamhill River


    • Standard Construction Contract Documents

      Blow-off pipe is to be C230 Red Brass, Schedule 40, 2 inch nominal diameter with threaded ends. Fittings, including elbows and caps, shall be threaded brass. S922-2.02 Service Saddle. Service saddle is to be 2 inch in conformance with S912 Corporation Stop and Connection; Abandon Existing Water Service at Tap (2 Inch and Smaller).


    • [DOCX File]Section 23 21 11 - BOILER PLANT PIPING SYSTEMS

      https://info.5y1.org/1-5-inch-pipe-tap_1_50d00f.html

      For strainers 100 mm (4 inch) pipe size and greater, diameter of openings shall be 1.3 mm (0.05 inch) on steam service, 3.2 mm (1/8 inch) on water service. Provide 80 mesh stainless steel screen liner on all strainers installed upstream of water meters or control valves.


    • [DOC File]GUIDELINES FOR THE INSTALLATION AND OPERATION OF

      https://info.5y1.org/1-5-inch-pipe-tap_1_41799f.html

      Wheel-type systems are very similar to the pipe-type system previously addressed (i.e., a long straight length of 4-5 inch (10-13 cm) pipe equipped with distributed sprinkler heads). However, in this case, instead of the pipe being disassembled to be moved, it is rolled down the field on 4-5 foot (1.2-1.5 m) diameter wheels (usually metal).


    • [DOCX File]SECTION 1: CONTACT INFORMATION/ RESPONSIBLITIES

      https://info.5y1.org/1-5-inch-pipe-tap_1_92ab50.html

      Fabric is embedded 1 to 1.5 feet below ground and secured to frame/posts with staples at max 8-inch spacing. Posts are stable, fabric is tight and without rips or frayed areas. Sediments accumulation ___% of design capacity.


    • [DOCX File]SECTION 230520 - PIPING SPECIALTIES FOR HVAC PIPING

      https://info.5y1.org/1-5-inch-pipe-tap_1_9688b7.html

      Gauges and Thermometers: Provide two pressure gauge adapters with 1/8-inch o.d. probe and two 5-inch stem pocket test thermometers, 25-125ºF for chilled water, 40240ºF for heating water. STRAINERS Acceptable Manufacturers:


    • “CC” Threads

      as a replacement for lead or steel service. Unibell Association of PVC Pipe Manufacturers. General Terms. Pg 1 110. 1/4 Bend 110® Compression Connection (CTS, IPS PE) Valve or coupling with a 90( bend. 1/8 Bend Valve or coupling with a 45( bend. 85-5-5-5 85% Copper, 5% Tin, 5% Lead, 5% Zinc-Brass. Invented by Hieronymus Mueller


    • Norfolk Wastewater Details - Official Website | Official ...

      CS 16 Minimum allowable angles for precast manholes with PVC and DI pipe. Norfolk Water Details. CW 01 Tap installation typical for new construction. CW 02 Fire hydrant installation. CW 03 Water main separation. CW 04 5/8-inch to 1-inch water meter box and cover. CW 05 1 1/2-inch to 2-inch water meter vault and cover


Nearby & related entries: