1 or 2 803 803 1 0 0
[PDF File]alloy 803 - Special Metals Corporation
https://info.5y1.org/1-or-2-803-803-1-0-0_1_e9d77f.html
INCOLOY® alloy 803 (UNS S35045), an iron-nickel- chromium alloy, is designed for use in petrochemical, chemical and thermal processing applications. The nickel and chromium contents of alloy 803 are higher than those of INCOLOY alloys 800H and 800HT®.
[PDF File]INTERIOR FINISHES AND FIRE PROTECTION SYSTEMS
https://info.5y1.org/1-or-2-803-803-1-0-0_1_1a587f.html
803.1.3 or 803.1.4. 803.8 Expanded vinyl ceiling coverings. Where used as interior ceiling finish materials, expanded vinyl ceiling coverings shall be tested in the manner intended for use, using the product mounting system, including adhesive, and shall comply with the requirements of
[PDF File]Interior Finish Decorative Materials and Furnishings
https://info.5y1.org/1-or-2-803-803-1-0-0_1_45e38b.html
803.5.1.1 or 803.5.1.2 when tested in the manner intended for use in accordance with NFPA 265 using the product-mounting system (including adhesive) of actual use, or 3. The covering shall meet the criteria of Section 803.1.2.1 when tested in accordance with NFPA 286 using the product-mounting system (including adhe-sive) of actual use.
CHAPTER 8 INTERIOR FINISHES
CHAPTER 8 INTERIOR FINISHES User notes: About this chapter: Chapter 8 contains the performance requirements for controlling fire growth and smoke propagation within buildings by restricting interior finish and decorative materials.
[PDF File]CHAPTER 8 INTERIOR FINISHES
https://info.5y1.org/1-or-2-803-803-1-0-0_1_75b7bf.html
903.3.1.1 or 903.3.1.2. 803.6.2 Room corner test, textiles. Textile wall coverings shall meet the criteria of Section 803.6.2.1 when tested in the manner intended for use in accordance with the Method B protocol of NFPA 265 using the product-mounting sys-tem, including adhesive. 803.6.2.1 Method B test protocol. During the 40 kW exposure, the ...
[PDF File]INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS
https://info.5y1.org/1-or-2-803-803-1-0-0_1_7418ba.html
803.1.2.1. Interior wall and ceiling finish materials tested in accordance with NFPA 286 and meeting the acceptance criteria of Section 803.1.2.1 shall be allowed to be used where a Class A classification in accordance with ASTM E 84 is required. 803.1.2.1 Acceptance criteria for NFPA 286. The interior finish shall comply with the following: 1.
[PDF File]CHAPTER 8 INTERIOR FINISHES
https://info.5y1.org/1-or-2-803-803-1-0-0_1_9de3f2.html
tion 803.1.2. 803.1.2 Room cornertest forinteriorwallorceilingfin-ishmaterials.Interior wall or ceiling finish materials shall be permitted to be tested in accordance with NFPA 286. Interior wall or ceiling finish materials tested in accordance with NFPA 286 shall comply with Section 803.1.2.1. 803.1.2.1 Acceptance criteria for NFPA 286. During