    • [PDF File]Type WR – Wide range aluminum tap connectors - ABB

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_c48b09.html

      C5 Tap Main L A B Main Tap Supplemental “O” and “D” die seven connector program • For combinations of aluminum-aluminum and aluminum-copper conductors


    • [PDF File]Quadruplex Service Drop Aluminum Conductor - Priority Wire

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_4d4ce0.html

      Pinto 4 7/w 0.045 4 7 881 0.73 223 207 100 80 All values are nominal and subject to correction *Designated sizes are ACSR 6/1, diameter, equivalent resistivity per ASTM B399 for 6201. **Conductor temperature of 90ºC for XLP, 75ºC for Poly; ambient temperature of 40ºC, emissivity 0.9; 2ft/sec. wind in sun.


    • [PDF File]336.4-636 AAC Series Tap Connec - Wesco

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_ec1530.html

      266.8 acsr 36/7, 300 aac, 336.4, 397.5 acsr 24/7 .628" - .772" 477633 336.4 acsr 26/7, 397, 477, 500 mcm, 556 aac .720" - .858" 477434 #6, #4, #2 .162" - .316" 556956 #2, #1, 1/0 .292" - .398" 556892 1/0 , 2/0, 3/0, 4/0 aac .368" - .522 556783 4/0, 250, 266.8, 300 mcm, 336 aac, 350 mcm .522" - .680" 556638 350 mcm, 336.4, 397.5, 477 aac .680 ...


    • [PDF File]Aluminum lugs

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_bd5d48.html

      al 400-48 400, 397.5 – 336.4 (26/7), 397.5 (18/1) 1⁄2 21⁄2 47⁄8 11⁄4 15⁄8 AL 400-58 5 ⁄ 8 2 1 ⁄ 2 4 7 ⁄ 8 1 1 ⁄ 4 1 5 ⁄ 8 AL 500-48 500, 477 600 379.5 (26/7), 477 (18/1) 1 ⁄ 2 106A, 300, 317, 1 5 ⁄ 16 , 14A 3 5 7 ⁄ 16 1 1 ⁄ 2 1 3 ⁄ 4


    • [PDF File]336.4 Thru 636 AAC Series Tap Connector Specifications - Wesco

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_155264.html

      350120 336.4 aac .609" - .684" #1, 1/0, 1/0 sol .382" - .338" 1.066" - .913" 350121 336.4 acsr(18/1) 1/0, 2/0, 3/0 sol .447" - .398" 1.131" - .973" 350122 350 kcmils 2/0, 3/0, 4/0 sol .502" - .460" 1.185" - 1.035" 350123 4/0, 250, 300 sol .576" - .522" 1.260" - 1.097" 350124 266.8, 300 .642" - .595"1.326" - 1.170"


    • [PDF File]CATALOG Blackburn® Overhead connectors - ABB

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_101f3d.html

      RG 5 1/0 & 2/0 1/0 & 2/0 511/16 RX 5 3/0-336.4 3/0-336.4 67/16 Note: For special die requirements, additional pin lengths and offset pin styles, please consult your ...


    • [PDF File]05.01 SAGS FOR PRIMARY CONDUCTOR SAG AND TENSION GENERAL ...

      https://info.5y1.org/1-or-3-2-0-5-336-336_1_8fd5e2.html

      multiplier to convert kw to kva 1.00 1.05 1.11 1.18 1.25 2.00 2.50 3.33 1. for 240 volt base, multiply volts drop above by 2. 2. for 120/208 balanced 3-phase loads, multiply volts drop above by 2/3. 3. for 277/480 balanced 3-phase loads, multiply volts drop above by 1/8. 4. for 240 volt balanced 3-phase loads, multiply volts drop above by 1/2.