112 5 kva transformer size

    • [DOCX File]PSG Section 16461 - Eaton

      https://info.5y1.org/112-5-kva-transformer-size_1_b4dc00.html

      On three-phase units rated [15 kVA and above] [30 kVA and above] [45 kVA and above] [75 kVA and above] [112.5 kVA and above] and single-phase units rated [15 kVA and above] [25 kVA and above] [37.5 kVA and above] [50 kVA and above] the coils assembly shall be impregnated with non-hydroscopic, thermosetting varnish and cured to reduce hot spots ...

      112.5 kva transformer weight


    • [DOCX File]SECTION 16460 DRY-TYPE TRANSFORMERS

      https://info.5y1.org/112-5-kva-transformer-size_1_e0e431.html

      Sep 08, 2020 · Minimum Linear Load Efficiency: NEMA TP-1 98.23 percent for 30 kVA, 98.4 percent for 45kVA, 98.6 percent for 75 kVA, 98.74 percent for 112.5kVA, 98.83 percent for 150 kVA, 98.94 percent for 225 kVA, 99.02 percent for 300 kVA, 99.14 percent for 500 kVA.

      112.5kva transformer eaton


    • [DOC File]ELECTRICAL DESIGN CRITERIA

      https://info.5y1.org/112-5-kva-transformer-size_1_f9b6c1.html

      Minimum wire size and over current protection shall be sized per NEC Table 450.3B at 100% of the transformer’s KVA rating. Electrical Motors: Ensure motors are energy efficient. Provide motors with a minimum power factor of 0.85 at 100 percent load. Motor Efficiency: Comply with IEEE Test Procedure 112…

      siemens 112.5 kva transformer dimensions


    • [DOCX File]SECTION 16460 DRY-TYPE TRANSFORMERS

      https://info.5y1.org/112-5-kva-transformer-size_1_76536a.html

      Minimum Linear Load Efficiency: NEMA TP-1 and EPA ENERGY STAR compliant; 97.5 percent for 30 kVA, 97.7 percent for 45kVA, 98.0 percent for 75 kVA, 98.2 percent for 112.5kVA, 98.3 percent for 150 kVA, 98.5 percent for 225 kVA, 98.6 percent for 300 kVA, 98.7 percent for 500 kVA.

      112.5 kva transformer amps


    • [DOC File]Typical Specification, ULLTRA type L

      https://info.5y1.org/112-5-kva-transformer-size_1_9d28a9.html

      [Select the below text if specifying Low Load Range Transformer] 15 kVA: 50 watts, 30 kVA: 90 watts, 45 kVA: 120 watts, 75 kVA: 170 watts, 112.5kVA: 250 watts, 150 kVA: 310 watts, 225 kVA: 430 watts, 300 kVA: 530 watts . Submit for approval before shipment certified type test results for maximum no load losses for each size of transformer ...

      112 kva transformer wiring


    • [DOC File]SECTION 16326000 - ABB

      https://info.5y1.org/112-5-kva-transformer-size_1_e1b9be.html

      Transformer windings, insulation class 2.5 kV (2400v) and above, shall be wound using wire conductors. ... Sound level shall not exceed the maximum specified by ANSI C57.12.01 for applicable KVA size of dry-type transformer. ... KVA Rating: 112.5 225 300 500 750 1000 1500 2000 2500 3000 3750 5000 7500 10000 OTHER (_____)

      112.5 kva transformer dimensions