120/240 single phase. 120/208 3 phase. 277/480 3 phase. The 120/240 configuration is obtained from the low-side of a HV/240 volt transformer, where HV is the rated voltage on the high voltage side, and the 240 is the rated voltage on the low voltage side. Then a center tap is connected to the low voltage winding and grounded along with the low ...
[DOCX File]SECTION 283111 - DIGITAL, ADDRESSABLE FIRE-ALARM …
https://info.5y1.org/120-208-volt-single-phase_1_14659a.html
CHANGE 120/208 TO 120/240 IF REQUIRED. A. Color Coding for 120/208 Volt Electric Light and Power Wiring: 1. Color Code: a. 2 wire circuit - black, white. b. 3 wire circuit - black, red, white. c. 4 wire circuit - black, red, blue, white. 2. White to be used only for an insulated grounded conductor (neutral).
[DOC File]Chapter 1: DESIGN PROCESS
https://info.5y1.org/120-208-volt-single-phase_1_2e048d.html
The electrical supply for 400 – 1500 models shall be 120 volt / 60 hertz / single phase; on 2000 models the electrical supply shall be 208 volt / 60 hertz / 3 phase wye 10A leg. Two additional electrical connections are provided internal to the boiler cabinet for the connection of optional high and low gas pressure switches.
[DOC File]THE NEC® INTRODUCTION
https://info.5y1.org/120-208-volt-single-phase_1_77b8c4.html
The system shall be designed to operate from 120, 208, 277 Volt, single phase, 60 Hz service and supply the maintained lighting load under both normal and emergency conditions. The DC to AC inverter shall be of the solid-state type with ferroresonant output transformer to provide 120/208/277 Volt, single phase, 60 Hz output.
[DOC File]Introduction to Distribution Systems
https://info.5y1.org/120-208-volt-single-phase_1_7d4f09.html
120 / 208 volt, 3 phase, 4 wire, Wye system. Phase A – Black. Phase B – Red. Phase C – Blue. Neutral – White No. 6 & smaller – White / Gray only. Larger than No. 6 may be other than white (marked per NEC 200-6) Ground – Green (marked per NEC 250-119) 120 / 240 volt, 3 phase, 4 wire, Delta system. Phase …
208V Single Phase Power: What You Need to Know
Jun 17, 2002 · 120/208V, 3 phase, 4W- This is a good choice for a three phase system because you can balance 120 volt loads around the wye to equally load the generator. 208V single phase and 208V three phase loads can be used as well as 120V single phase loads. Motors must be rated 200 volt operation; 240 volt resistance heating equipment used on a 208V ...
[DOC File]WIRING, GENERAL 600 VOLTS AND UNDER [DTK:ss]
https://info.5y1.org/120-208-volt-single-phase_1_e347ef.html
Several standard system voltage and wiring arrangements are in use in North America and include: 120 volt, 1-phase, 2-wire; 120/240 volt, 1-phase, 3-wire; 120/208 volt, 1-phase, 3-wire; 120/208 volt, 3-phase, 4-wire; 277/480 volt, 3-phase, 4-wire; and 2400/4160 volt, 3-phase, 4-wire. Typical applications for each of these arrangements are ...
[DOCX File]HTP - Water and Space Heating
https://info.5y1.org/120-208-volt-single-phase_1_18ae97.html
Choose one: Single Line Supply Dual Line Supply (Charges will apply). CUSTOMER’S SERVICE FACILITIES: NEW REQUIRED PRESENT ADEQUATE METERING: SELF CONTAINED (required for 120/240 and 120/208 volt up to and including 600 amp, and 277/480 volt service up to and including 400 Amp svc.) CT CABINET
[DOC File]Industrial & Commercial Services - PPL Electric
https://info.5y1.org/120-208-volt-single-phase_1_4e9a0d.html
Wiring for temporary light and single phase power shall, in general, consist of 3 wire, 120/240 volt or 4 wire, 120/208 volt feeders, with branch circuits of #12 conductors minimum. 1) Install branch circuits with suitable fluorescent fixtures or incandescent lampholders for temporary lighting as required to maintain a minimum of 10 foot ...
[DOCX File]HTP - Water and Space Heating
https://info.5y1.org/120-208-volt-single-phase_1_f68875.html
The electrical supply for 400 – 1500 models shall be 120 volt / 60 hertz / single phase; on 2000 models the electrical supply shall be 208 volt / 60 hertz / 3 phase wye 10A leg. Two additional electrical connections are provided internal to the VWH cabinet for the connection of optional high and low gas pressure switches.