[DOC File]SECTION I - OAS
https://info.5y1.org/150-amp-disconnect-panel-box_1_e89464.html
c) A main disconnect may be mounted in a box of its own at the meter location or be included as part of the circuit breaker panel. If the circuit breaker panel is to be more than 10 feet from where the service entrance wires come through the wall of the building, then you must use a separate disconnect box mounted near the meter and service ...
[DOCX File]ELECTRICAL FOR STEAM UTILITY DISTRIBUTION
https://info.5y1.org/150-amp-disconnect-panel-box_1_5b1aca.html
Switch Enclosures: Provide disconnect switches with NEMA enclosures 1, 3R, 4X, 7, or 12 as indicated on the Drawings, or in absence thereof, as determined by installer to fulfill the requirements of the environment. NEMA 4X disconnect switch enclosures shall be …
[DOC File]State of Washington
https://info.5y1.org/150-amp-disconnect-panel-box_1_b7c4c2.html
Nov 20, 2012 · 150 amp electrical box, (5) 4-plex outlets, and (2) 12in x 12in cast in wall vents. 1 EA $ 9,319.50. H Insulation Packages: Utility Building, 8ft x 10ft 1 Roof Insulation Package, Rigid Foam Board: Securely fasten to ceiling, insulation covered by 3/4” fire resistant plywood, two coats painted, approximately R-19. 1 EA $ 1,077.30
[DOC File]Utilities Charges & Availability
https://info.5y1.org/150-amp-disconnect-panel-box_1_db46d3.html
60 amp Disconnect Box: (Power Drop) 1 (1) 208V - Three Phase 60 amps. 1 $475.00 $550.00 100 amp breaker panel: (Options) 1 (2) 120v -Single Phase - 20amp / Quad Box 5 $150.00 each $175.00 2 120v -Single Phase - 20amp (Balcony) 5 $150.00 each $175.00 3 208V -Single Phase - 20amp. 5 $300.00 each $345.00 4 Stage 120v - Single Phase - Outlets 10 ...
[DOC File]GSA Advantage!
https://info.5y1.org/150-amp-disconnect-panel-box_1_d08568.html
Output is 3 each 20 Amp Hubbell or equal L21-20R Flanged Twist Lock Receptacles and 2 each 20 Amp Hubbell or equal 20 Amp Spec Grade Duplex Receptacles (Black). 100 Amp Custom Built Clear View Panel that is UL Listed for Exposition Halls and Similar Locations; 3-Phase, 4-Pole, 5-Wire, 120/208Y.
[DOC File]MAINTENANCE AND REPAIR OF MAIN SWITCHGEAR
https://info.5y1.org/150-amp-disconnect-panel-box_1_d748de.html
Branch Breakers: 2-250amp JD, 4-100 amp, 1-150 amp FA, and 8-200amp. Two (2) TVSS Units. Building A. Two (2) Eaton 4160V, 600 amp 3 phase 3 wires Air Interrupter Switches. Two (2) Eaton 1500KVA, 5KV-208Y/120v oil filled transformers. Includes oil sampling. One (1) Main-Tie-Eaton 208Y/120v, 65ka, 1200 amp switchboard
[DOC File]PS202002EN - Eaton
https://info.5y1.org/150-amp-disconnect-panel-box_1_8d1995.html
[ ] 35 KV DEADFRONT, CURRENTS BELOW 200 AMPS: The high voltage bushing shall be a one-piece, 150 kV, 200-amp large interface load-break bushing (Re: Catalog Data CA800021EN). [ ] 15/25/35 KV DEADFRONT, CURRENTS ABOVE 200 AMPS: The high voltage bushing shall be a 600A dead-break primary one-piece bushing externally removable, 3Ø rated, integral ...
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/150-amp-disconnect-panel-box_1_7ba407.html
The main breaker in the panel serves as a single point to shut power off for the entire building. Remotely Located Panels from a Main Panel. 1.2., & 3 of single panel service apply to the main panel. The subfed conductors and the circuit breakers in the main panel are sized to the ampacity rating of …