    • [DOC File]PART 2 - PRODUCT

      https://info.5y1.org/2-5-mm-to-inch_1_d9ad5f.html

      2. Brick Pattern: Horizontal aluminum rods (5/16 inch (7.9 mm), spaced vertically at 2 inch (50.8 mm) O.C., with links spaced horizontally at 9 inch (228.6 mm) O.C. to form a brick pattern with aluminum spacers at the top and bottom of each link.]


    • [DOCX File]Ornamental Welded Wire Fences and Gates - Ametco

      https://info.5y1.org/2-5-mm-to-inch_1_4c292b.html

      2.Horizontal wires: Two [5/16 inch] [8 mm] diameter wires encasing vertical wires and spaced at [8 inches.] [203 mm.] 3.Pickets: Form by extending vertical wires [1 inch] [25 mm] above top horizontal wire.


    • [DOCX File]Ornamental Steel Fences and Gates - Steel Gates

      https://info.5y1.org/2-5-mm-to-inch_1_2c3a4c.html

      2.Cross rods: [5/32 inch] [4 mm] diameter rods welded perpendicular to back side of louver bars and spaced at [5-7/32 inches] [133 mm.] 3.Perimeter side support bars: [2 by 1/4 inch] [51 by 6 mm] flat bars.


    • [DOC File]SECTION 220529 - HANGERS AND SUPPORTS FOR PLUMBING PIPING ...

      https://info.5y1.org/2-5-mm-to-inch_1_f920dc.html

      Install hangers to provide at least 1/2 inch (13 mm) space between finished covering and adjacent work. Place a hanger within 12 inches (300 mm) of each horizontal elbow. Use hangers with at least 1-1/2 inch (38 mm) vertical adjustment. Support horizontal cast iron pipe adjacent to each hub, with 5 feet (1.5 m) maximum spacing between hangers.


    • [DOCX File]Short version of PCB Layout Guideline for DDR3 UDIMM and ...

      https://info.5y1.org/2-5-mm-to-inch_1_fa963d.html

      For memory clocks, use an external parallel termination of 75 differential at the end of the fly-by daisy chain topology on the memory clocks. Using fly-by daisy chain topology helps reduce any stub reflection. Keep the length of the traces to the termination to within 0.5 inch (14 mm). Use resistors with tolerances of 1 to 2%.


    • [DOC File]Snowfall rate thresholds for light, moderate and heavy

      https://info.5y1.org/2-5-mm-to-inch_1_64cf87.html

      > 2.5 mm/hr: Heavy . The published holdover times are based on using the thresholds of 1 mm/hr and 2.5 mm/hour for snowfall rate transitions between light to moderate, and moderate to heavy, respectively. The upper threshold is of particular importance since there are no holdover times defined for heavy snow, at rates greater than 2.5 mm/hour.


    • [DOCX File]All goods and services supplied under this order must meet ...

      https://info.5y1.org/2-5-mm-to-inch_1_86e01b.html

      Pipe Galvanized 2.5-inch 2.5 mm Length 4 meter for Stand (see the drawing) PCS. 4. 48. Pipe Galvanized 1 inch Length 6 meter for X bracing (see the drawing) PCS. 5. 49. Pipe Galvanized 3/4 inch for Stair and reling Length 6 meter (see the drawing) PCS. 2. 50. Angle Iron 50X50X3mm for water tank cover (see the drawing)


    • SECTION 096900 - ACCESS FLOORING

      The entire assembly shall allow 2 inches (50 mm) of vertical adjustment in 1/64 inch (.004 mm) increments by means of a threaded stud. The assembly shall provide a mechanical means to lock the floor in level plane and adjustments shall be capable of being made without the use of special tools.


    • [DOC File]Presto Products Company

      https://info.5y1.org/2-5-mm-to-inch_1_f9ca8b.html

      Weld spacing for GW30V-cell sections shall be 17.5 inches plus or minus 0.10 inch (445 mm plus or minus 2.5 mm). Weld spacing for GW40V-cell sections shall be: 28.0 inches plus or minus 0.10 inch (771 mm plus or minus 2.5 mm). Cell Seam Strength Tests. 1. Minimum seam strengths are required by design and shall be reported in test results.



    • [DOC File]SECTION 1507 - Florida Building

      https://info.5y1.org/2-5-mm-to-inch_1_266cfc.html

      Fasteners for asphalt shingles shall be galvanized, stainless steel, aluminum or copper roofing nails, minimum 12 gage [0.105 inch (2.67 mm)] shank with a minimum 0.375 inch-diameter (9.5 mm) head, of a length to penetrate through the roofing materials and a minimum of 0.75 inch (19.1 mm) into the roof sheathing.


    • [DOC File]Presto Products Company

      https://info.5y1.org/2-5-mm-to-inch_1_f18a4c.html

      Ultrasonic weld melt-pool width shall be 1.0 inch (25 mm) maximum. Specifier Note: Select the desired cell type and delete the other. Coordinate with 2.2.C above. Weld spacing for GW20V-cell sections shall be 14.0 inches plus or minus 0.10 inch (356 mm plus or minus 2.5 mm).


    • [DOC File]Preparation of Papers in Two-Column Format

      https://info.5y1.org/2-5-mm-to-inch_1_572c49.html

      Each column measures 3.5 inches wide, with a 0.25-inch measurement between the columns. 2) A4 Margins: top = 19 mm, bottom = 43 mm, side = 13 mm. The A4 column width is 88 mm (3.45 in). The space between the two columns is 4 mm (0.17 mm). Paragraph indentation is 3.5 mm (0.14 in). Left- and right-justify your columns.


    • [DOCX File]SECTION 08 71 13 - AUTOMATIC DOOR OPERATORS

      https://info.5y1.org/2-5-mm-to-inch_1_2a5458.html

      ASTM B209, Type 6063T5 aluminum alloy, 112 mm (41/2 inches) wide by 140 mm (5.5 inches) high by 3.2 mm (0.125 inch) thick, aluminum extrusions with enclosed end caps for application to 100 mm (4 inches) and larger frame systems.


    • [DOC File]SECTION 092900 - GYPSUM BOARD

      https://info.5y1.org/2-5-mm-to-inch_1_577293.html

      Core: [1/2 inch (12.7 mm)] [5/8 inch 15.9 mm)] [As required by fire-resistance-rated assembly indicated on drawings]. Long Edges: Tapered. Performance: Rating of 10 per ASTM D3273. Acceptable Product: M-Bloc Type C with Mold and Moisture Resistance.