      1000 Series [15][20]-Amp Cable Reel with Locking Single Outlet Mobile End: Catalog No. CRCD123N50L[15][20]; rated [15][20] amps, 125 volts; 50-foot 12AWG 3C cable; not GFCI rated. 1000 Series 15-Amp Cable Reel with Ground Continuity Monitor Mobile End: Catalog No. CRCD123N[35][50]G15; rated 15 amps, 125 volts; [35][50] foot 12AWG 3C cable; not ...

      20 amp gfci receptacle


    • [DOC File]SECTION 262726 - WIRING DEVICES - RPM

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_35f7c9.html

      Locking Receptacles (other than 20 amp, 120 volt): NEMA configuration of proper size for loads indicated on plans or as required for equipment served. Provide outlets with standard plate, blank, receptacle, switch or cord hole, as required by outlet symbol. Multiple devices mounted on one piece gangplates of appropriate design.

      20 amp outdoor gfi


    • [DOCX File]Fine Homebuilding

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_38fc62.html

      Includes adding one (1) 20 amp GFCI outlet circuit to meet code (can share circuit with other bathrooms) Dining room - replace dining room table light and install four (4) 4" recessed lights Foyer - supply and install three (3) 4" recessed lights old work and replace one (1) ceiling mounted fixture

      20a gfci outlet


    • [DOC File]ELECTRICAL - Crowdstack

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_a52700.html

      A GFCI protected outlet shall be installed next to each bathroom basin per NEC 210-52(d). GARAGE & Basement receptacles shall have GFCI protection per 210-8(a). EXTERIOR outlets shall have a weatherproof enclosure & GFCI per NEC 410-57(a). GFCI outlet shall be installed at the front and rear of the house per NEC 210-52(e). Lighting:

      20 amp gfi receptacle price


    • SECTION 260500 - COMMON WORK RESULTS FOR ELECTRICAL

      Ground-fault circuit interrupting receptacles (GFCI's) shall be installed at the locations indicated. GFCI's shall be rated 125-volt, 20 amps and shall be . Hubbell GF-5362, or equal. Receptacles for hazardous locations shall be single gang receptacles with spring door. Receptacles shall have a …

      20 amp gfi outlet


    • [DOCX File]Design Manual 1040 Final - Wa

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_4d653c.html

      Aug 27, 2020 · The bulb should have a minimum of 1600 lumens. Each fixture is to be designed with a 20 amp rated ground fault circuit interrupt (GFCI) receptacle. A light switch is needed at each entrance to any common inspection area. For inspection areas with two or more entrances, three-way or four-way switches are required.

      lowes 20 amp gfci outlet


    • [DOC File]PART 1 - broward.k12.fl.us

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_605d0b.html

      Install one (1) quad receptacle outlet for every computer cart, each receptacle to be on its own dedicated 20 Amp circuit. Install two (2) G.F.I. duplex receptacle outlet for every communication outlet located above lab counter work area. Install one (1) quad receptacle outlet for each computer workstation in every office space.

      30 amp gfci outlet outdoor


    • [DOC File]Packaged Rooftop Cooling Unit and - Cultiva Systems

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_b35e2b.html

      Convenience Outlet: Shall be factory-installed and internally mounted with an externally accessible 115-v, 15-amp GFCI, female receptacle with hinged cover. The outlet shall require field-supplied 115-vac power supply wiring. Factory-wired GFI with a step-down transformer and 15.0 Amp breaker is also available. NEMA 3R Non-Fused Disconnect Switch:

      30 amp ground fault receptacle


    • PART II - INSPECTIONS

      All fifteen (15) and twenty (20) Ampere receptacles installed in bathrooms shall have ground-fault circuit-interrupter protection for personnel. (E3902.1) Outdoor Outlet

      20 amp gfci receptacle


    • [DOCX File]Section 13129

      https://info.5y1.org/20-amp-gfci-outlet-outdoor_1_f774f9.html

      Wiring Devices: One 120-V 20 amp duplex receptacle. Wiring Devices: One 120-V 20 amp GFCI power duplex receptacle with tester on exterior. Wiring Devices: One telephone/computer prep 3/4 inch (19 mm) conduit to junction box.