200 amp stainless steel disconnect
[DOC File]PSG Section 26 28 16.13 - Eaton
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_b52be5.html
NEMA 4X watertight corrosion resistant ([304] [316] grade stainless steel . Window Switches (Upper Viewing Window) Provide 200- to 800-ampere switches as shown on drawings with an upper viewing window to provide blade visibility when the switch door is closed. Enclosures shall be: NEMA 12 dust-tight and oil-tight special industry
[DOCX File]ARCAT, Inc.
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_56923a.html
A Separate 115-Volt, 15 Amp manual disconnect circuit is required. ... Material Stainless Steel. Bi-parting steel gate and shelves, powder coated. ... The Paca-Waiter, Model PW-200: Capacity: 200 lbs. Standard Car size: Width: 26 inches. Depth: 26 inches. Height 36 inches.
Home Page | Missouri Department of Transportation
An automatic disconnect device shall be included to protect the entire system in case of low voltage. (6) Disconnect and Enclosures: Disconnect plug and receptacle shall be determined by the current, voltage, and number of contacts required for proper operation. Connectors shall have screw terminations and accommodate a wire size of up to #12AWG.
[DOCX File]Liquid-filled, medium-voltage AR-VFI pad-mounted ...
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_e919ea.html
[]35 KV DEADFRONT, CURRENTS BELOW 200 AMPS: The high voltage bushing shall be a one-piece, 150 kV, 200-amp large interface load-break bushing (Re: Catalog Data CA800021EN). []15/25/35 KV DEADFRONT, CURRENTS ABOVE 200 AMPS: The high voltage bushing shall be a 600A dead-break primary one-piece bushing externally removable, 3Ø rated, integral design.
[DOCX File]SECTION 08 33 00 - COILING DOORS AND GRILLES
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_2da4e9.html
A36/A36M19Carbon Structural Steel. A240/A240M20Chromium and ChromiumNickel Stainless Steel Plate, Sheet, and Strip for Pressure Vessels and for General Applications. A653/A653M20Steel Sheet, ZincCoated (Galvanized) or ZincIron AlloyCoated (Galvannealed) by the HotDip Process. B20914Aluminum and AluminumAlloy Sheet and Plate.
[DOC File]Emergency Power System - altE Store
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_583f92.html
200 amp-hours@12vdc. and . ... If any corrosion is found to disconnect the cables, clean them with a mild solution of baking soda and water. ... and computers. The use of conformed coated circuit boards, plated copper bus bars, powder coated metal components, and stainless steel fasteners allows the unit to function in hostile environments ...
[DOC File]M E M O R A N D U M - Seattle
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_04b1e2.html
Continuous duty relay, Cole Hersee model 24143 (12 VDC) 200 amp, connected to ignition accessory is required to power non-factory provided switch panel. WELDING PROCESS AND CONTROL: All welds shall meet AWS standards for structural steel joints.
[DOCX File]SECTION 26 13 02 - DOA Home
https://info.5y1.org/200-amp-stainless-steel-disconnect_1_52303a.html
[The medium voltage switchgear units shall be equipped with three (3) 3-pole group operated, 600 amp rated switches and one (1) three phase 200 amp rated fused tap, with the 200 amp fused tap being fed from one of the 600 amp switches.