      One advantage of this system is that luminaires can be equipped with 277 volt ballasts reducing voltage drop for larger runs over the use of the more common 120 volt lights. In this system receptacles are fed through dry-type 480-120/240 volt single phase transformers. 208/120 volts, grounded wye-connected, three-phase, four-wire

      230 volt receptacle pin configurations


    • [DOCX File]SECTION 11 71 02, LABORATORY WASHING AND …

      https://info.5y1.org/208-230-volt-plug-types_1_9cc0cd.html

      The motor shall be a NEMA rated, open drip proof, 1800 RPM, with 1.15 service factor suitable for 208/230/460V electrical service, a specified in Section 22 05 12, GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT and Section 26 29 11, MOTOR CONTROLLERS.

      208 240 volt plug


    • [DOC File]SECTION 13204 - Government of New York

      https://info.5y1.org/208-230-volt-plug-types_1_fb7b85.html

      B. Remote Pump: Single phase 3/4 HP, 208/230 Vac; with control box and mechanical line leak detector; F.E. Petro STP-75 or Red Jacket P75 T-X (quick set finial). 1. Mechanical Line Leak Detector: F.E. Petro STP-MLD-D or Red Jacket FX-1DV. C. Manual Shutoff Valve: Brass, full port ball valve, 1 1/2 inch size, Jomar T-100NE, or Morrison Bros. 691B.

      nema 208 plug


    • [DOC File]GLORY STAR SERIES - North American HVAC

      https://info.5y1.org/208-230-volt-plug-types_1_ead26c.html

      Compressors are single phase, 115 or 230/208 volt, depending on the model unit. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal. All compressors are internally spring mounted and externally mounted on …

      220v 20 amp receptacle configurations


    • [DOC File]2017_HLS_Handbook.doc - ISBE

      https://info.5y1.org/208-230-volt-plug-types_1_21b841.html

      ELECTRICAL SYSTEM: Electric service is underground, rated 208/120 volt, 3 phase, 4 wire. The main service has a maximum demand of 800 ampere and is capable of 2000 ampere. The non-metallic sheathed cable used in some of the recent remodeling work is …

      230v 3 phase plug


    • [DOC File]Section 15010 Mechanical Provisions

      https://info.5y1.org/208-230-volt-plug-types_1_817fc4.html

      Electrical power supply shall be 208/220/230 volts, 60 cycle, single phase, (verify) with a control circuit transformer to reduce voltage to 120 volts for control circuit requirements only. 5. Any pressure vessel shall be guaranteed against thermal shock for 20 years when utilized in a closed loop Hydronic heating system with a temperature ...

      ac plug configurations


    • [DOCX File]CED Template

      https://info.5y1.org/208-230-volt-plug-types_1_ec560d.html

      The weigh / wrap equipment shall support wireless security (802.11i, Wi-Fi Protected Access (WPA2)) and EAP Types (EAP-Tunneled TLS (TTLS), Protected EAP (PEAP) and EAP-MSCHAPv2) The weigh / wrap equipment shall be capable of operating in wired mode and wireless mode. Memory, mass storage and processor requirements. Minimum of 1 GB RAM

      208 20 amp plug


    • [DOCX File]Section 22 61 19.74 - DENTAL COMPRESSED-AIR EQUIPMENT

      https://info.5y1.org/208-230-volt-plug-types_1_fa724b.html

      The motor shall be a NEMA rated, open dripproof, //1800// //3600// RPM, with 1.15 service factor suitable for “208/230/460V” electrical service, as specified in Section 22 05 12, GENERAL MOTOR REQUIREMENTS FOR PLUMBING EQUIPMENT.

      208 volt plug chart


    • [DOCX File]CED Template - Commissaries

      https://info.5y1.org/208-230-volt-plug-types_1_83cce3.html

      Information technology that is not an information system or a Platform Information Technology (PIT) system shall be designated by DeCA as an IT product, service or PIT and must be securely configured in accordance with applicable hardening guides, such as Security Technical Implementation Guide (STIG), security controls and shall obtain authorization from DeCA before it is connected to the ...

      230 volt receptacle pin configurations


    • [DOCX File]PART 1- GENERAL - Xylem

      https://info.5y1.org/208-230-volt-plug-types_1_742720.html

      -10°C to 55°C through 30 HP @ 380/460 volt, through 15 HP @ 208/230 volt 5% to 95% relative humidity, non-condensing. Elevation to 3,300 feet without derating.