This allows a single service to supply 120 V for lighting, 240 V single-phase for heating appliances, and 240 V three-phase for motor loads (such as air conditioning compressors). Two of the phases are 120 V to neutral, the third phase or "high leg" is 208 V to neutral.
SECTION 263213 - PACKAGED ENGINE GENERATOR
The generator shall be rated to operate at 480Y/277 and 208/120 Volts, three-phase, four-wire, wye-connected, 60 hertz, 1800 rpm. ... Such numbering and coding shall agree with those on the wiring diagram. Wiring shall go to terminal strips for intermediate connection unless wiring is contained in a cable or in a harness with keyed connectors.
[DOC File]208C Camera & Receiver Set User Manual
https://info.5y1.org/208-wiring-diagram_1_e8707f.html
208CA CMOS Color Wireless Micro Camera and Matching Receiver kit provides high quality wireless video transmission. It is an enhanced model with audio capability. It is used at homes, workshops, warehouses, schools, offices, stores, gas stations, and any places that wiring is not possible.
[DOC File]ELECTRICAL DESIGN CRITERIA
https://info.5y1.org/208-wiring-diagram_1_9a2dbe.html
L.3.4 Start 208 volt, 3 phase, motors of 50 horsepower and up by means of reduced voltage type starters. L.3.5 In general, start 460 volt, 3 phase motors of 200 horsepower and up by means of reduced voltage type starters. L.3.6 Furnish all 208 and 460 starters with control transformers supplying 120 volts for starter operating coil circuits.
[DOC File]IOMM A-C Cond-1 Installation Manual for Models ACH, ACX ...
https://info.5y1.org/208-wiring-diagram_1_103683.html
Voltage for 208/230 motors not less than 195 volts or more than 253 volts. All other voltages must be within 10% of nameplate ratings. Phase imbalance not to exceed 2%. All controls and safety switch circuits properly connected per wiring diagram. Factory installed wiring must not be changed without written factory approval.
Power Flame Incorporated
The control panel shall include (if 208, 230 or 460 volts) a din rail mounted control circuit transformer with integral fuses on both the primary and secondary windings. ... All wiring for remote panel electrical components will be factory pre-wired to a din rail mounted terminal strip within the control panel. A junction box pre-wired to the ...
[DOC File]INSTALLATION MANUAL
https://info.5y1.org/208-wiring-diagram_1_e531bb.html
See wiring diagram and/or Tables 18-20 for wire size, fuse/circuit breaker size, and ground wire sizes. The use of cable connectors on incoming power supply wires to relieve any strain on wiring is recommended. ... Table 18: Wiring Requirements – 208/230 VAC Electric Heat 18-37 kBTU Models + Refer to the National Electrical Code Table 250-95 ...