    • [DOCX File]Xylem’s trusted, industry-leading, residential and ...

      https://info.5y1.org/208v-3-phase-ups_1_047ba8.html

      • 208V 1-Phase & 208V 3-Phase • 230V 1-Phase & 230V 3-Phase • 380V 3-Phase • 460V 3-Phase • 575V 3-Phase. 2.3 Manufactured Unit. ... This job site visit shall occur only after all hook-ups, tie-ins, and terminations have been completed and signed-off on the manufacturer's start-up request form. B. The system manufacturer's factory ...


    • [DOC File]Powerware 9155 - Eaton

      https://info.5y1.org/208v-3-phase-ups_1_4a2fc4.html

      STATIC UNINTERRUPTIBLE POWER SUPPLY. GUIDE SPECIFICATION: FOR 8-15 kVA, SINGLE PHASE OUTPUT, UNINTERRUPTIBLE POWER SYSTEM. ... 5% THD maximum phase to neutral into a maximum rated non-linear load (7% phase to phase) ... Option Receptacle Breaker Voltage A 5-15R2 15A 120V B L5-15R2 15A 120V C 6-15R2 15A 208V D L6-15R2 15A 208V E 5-20R2(UL) 20A ...


    • [DOC File]TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA

      https://info.5y1.org/208v-3-phase-ups_1_85dbbf.html

      [ ] VAC, 3 phase, 4 wires plus-ground . Battery Autonomy: The Inverter shall be capable of operating at full load for 90 minutes on battery power, at a temperature of 25 C. ... UPS Events time and date stamp of up to 50 scrolling events with freeze function . ... (for 208V only) or on a wall that is adjacent to the cabinet. 10% Input Current ...


    • [DOC File]Memorandum for General RFP Configuration

      https://info.5y1.org/208v-3-phase-ups_1_7d4acf.html

      The UPS battery shall be sized for 1 at a Power Factor of 100% for 30 minutes. The UPS shall be sized for 60 kVA and 60 kW load. The system shall be rated for full kW output in the 80 kVA/kW frame size (can be configured with up to nine 10kW power modules for N+1). Input: AC Input Nominal Voltage: 208 V, 3 Phase, 4 wire, 60 Hz


    • [DOCX File]1.01 - Power management solutions | Eaton

      https://info.5y1.org/208v-3-phase-ups_1_a0ae2d.html

      Nominal output voltage 208V or 220V, 3-phase, 3-wire or 4-wire plus ground at the UPS output terminals. Steady-state voltage regulation (in inverter) shall be within +/-



    • [DOCX File]DCSS Operational Policy and Procedures - Home - DATACENTER

      https://info.5y1.org/208v-3-phase-ups_1_9d5195.html

      Standard power for the server cabinet in the data center is 3 phase 208V 30 and 60 amps. Each PDU will be supplied by two different distribution panels to guarantee effective redundancy. Customers are expected to use provided PDUs. Standard is 3 phase 208V 30 amps.


    • [DOC File]Powerware 9390 40-160kVA Guide Spec

      https://info.5y1.org/208v-3-phase-ups_1_354a18.html

      Nominal output voltage 208 VAC, 3-phase, 3 wire or 4-wire (or 480V, 3-phase, 3-wire or 4-wire) plus ground at the output of the Integrated Distribution and Bypass cabinet. Output wiring configuration is based upon input wiring configuration for systems without internal transformers.


    • [DOCX File]DCSS Operational Policy and Procedures

      https://info.5y1.org/208v-3-phase-ups_1_927286.html

      1.6.1 Only F&S authorized electrical service provider may open or change any electrical panel or power distribution unit. Standard power for the server cabinet in the data center is 3 phase 208V 30 and 60 amps. Each PDU will be supplied by two different distribution panels to guarantee effective redundancy.


    • [DOCX File]hhsc.org

      https://info.5y1.org/208v-3-phase-ups_1_b1ba94.html

      ADDENDUM #3. September 17, 2020. TO:Potential Offerors. ... What power is available at the site ( 3 phase or single, 480V, 208V ? how many amps service) ? A: all. A new panel will be installed with required amps. ... 3.6.1.1 KVA of existing UPS and location with respect to datacenter or will a new UPS be required? Voltage of UPS?


    • [DOC File]Rosegarden Branch Library

      https://info.5y1.org/208v-3-phase-ups_1_15253d.html

      phase: 3 a :bussing wire: 4 :mounting load a b c bkr ckt abc ckt bkr a b c load lights - 101-102 1.2 20a-1p 1 2 20a-1p 0.8 lights - 113 lights - 103-110 1.0 20a-1p 3 4 20a-1p 0.9 lights - 113 spare 0.0 20a-1p 5 6 20a-1p 1.0 lights - 113 exterior lights


    • [DOC File]SECTION 263353 - STATIC UNINTERRUPTIBLE POWER SUPPLY

      https://info.5y1.org/208v-3-phase-ups_1_7e14f4.html

      The UPS shall be capable of sustaining a total equipment load of 80KVA/64KW. The UPS shall be equipped with a battery system capable of supplying the load at rated voltage, for a minimum period of 15 minutes for 80KVA of load. ELECTRICAL CHARACTERISTICS. Input: Voltage: 208V AC +10 percent, -15 percent, 3-phase. Frequency: 60 Hz, ±5 percent.


    • [DOC File]1100 Specification

      https://info.5y1.org/208v-3-phase-ups_1_358d37.html

      Nominal output voltage: 120V/208V. Number of phase: 3 phase, 4 wire, plus ground. Nominal dynamic Voltage regulation: ±1% for balanced load. ±2% for unbalanced load. Voltage balance: 1% Manually adjustable output voltage: ±3% range. Voltage transient response: 100% step load: ±3%. Loss or return of AC input: ±1%.


    • [DOC File]TECHNICAL SPECIFICATION FOR A 3 TO 15 KVA

      https://info.5y1.org/208v-3-phase-ups_1_b8ae82.html

      [ ] VAC, 3 phase, 4 wires plus-ground . Battery Autonomy: The Inverter shall be capable of operating at full load for 90 minutes on battery power, at a temperature of 25 C. ... UPS Events time and date stamp of up to 50 scrolling events with freeze function . ... (for 208V only) or on a wall that is adjacent to the cabinet. 2.8.10 10% Input ...


    • [DOC File]Crucial Power Products

      https://info.5y1.org/208v-3-phase-ups_1_713c6a.html

      1 Phase UPS Functional Block Diagram – Single Line Diagram Dwg #: 6001-033-03 . UPS & Battery Cabinet Seismic Certification Drawing – Dwg. 6002-1658 (09-0319-A) Single Phase UPS with Load Center – Dwg # 6001-032-19. Single Phase External Wrap around by-pass Panel: 3KVA TO 20 KVA Dwg. 6001-032-31 & 6001-032-31S. TABLES