Installation Instructions: Manufacturer’s installation instructions. ... It is common for this leakage current to exceed the UL limit for a GFCI outlet (5 milliamps). A physical disconnect in the Off state eliminates current leakage and prevent electric shock when servicing the load. ... 120V/20A Dual Dimmer Module [Leviton LMS p/n A20DD-012 ...
[DOCX File]END OF SECTION
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_f956b7.html
20a. duplex receptacles installed and prewired, with three No. 12 copper conductors to the junction box at the top of the pole. Voice/Data Provisions: Each pole shall have knockouts for installation of a [modular voice/data outlet as specified in Section . 27 10 05, "Voice/Data System Provisions/Cabling"].
[DOC File]afcf.umaryland.edu
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_19747f.html
Receptacles shall be flush, duplex, grounding type, 20A, 2P, 3W, 125VAC, NEMA 5-20R straight blade, ivory nylon or high-strength thermoplastic material unless indicated as special purpose outlet. Receptacles shall be designed to accept standard two-wire parallel connector caps and shall grip both sides of the connector wire.
[DOC File]SECTION 262726 - WIRING DEVICES
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_c3e6fb.html
Leviton Mfg. Company Inc. (Leviton). Pass & Seymour/Legrand; Wiring Devices & Accessories (Pass & Seymour). STRAIGHT BLADE RECEPTACLES. Convenience Receptacles, 125 V, 20 A: Comply with NEMA WD 1, NEMA WD 6 configuration 5-20R, and UL 498. Products: Subject to compliance with requirements, provide one (1) of the following:
[DOC File]SECTION 16050 - Green Woodlands
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_e12a9d.html
Install cover plates on wiring devices. All devices shall be specification grade LEVITON 5362 SERIES and 1221 SERIES – 20A. Color by ARCHITECT. Where GFCI devices are indicated they shall be of non-LED type. Where groups of devices are shown, they shall be installed in approved metal gangable boxes with one piece faceplates.
[DOCX File]32 92 00 - Fort Wayne, Indiana
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_1166c2.html
Nov 16, 2018 · GFCI Trip: Test for tripping values specified in UL 1436 and UL 943. Using the test plug, verify that the device and its outlet box are securely mounted. Tests shall be diagnostic, indicating damaged conductors, high resistance at the circuit breaker, poor connections, inadequate fault current path, defective devices, or similar problems.
[DOCX File]ARCAT, Inc.
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_b67b49.html
Spec. Grade Renu Tamper-Resistant Self-Test GFCI by Leviton Mfg. Co., Inc.; UL Listed, CSA Certified, colors as selected from manufacturer's Renu colors. 15 amp, 125 volt, feed through terminals, std (RGF15 Series). 25 amp, 125 volt feed through terminals, std. ** NOTE TO SPECIFIER ** Delete products not required. AFCI RECEPTACLES
[DOC File]SECTION 16140
https://info.5y1.org/20a-gfci-outlet-leviton-instructions_1_a5205f.html
2. Duplex receptacle rated 20A (NEMA 5-20R), circuit ampacity 20A; Bryant’s GFR53FT, Crouse-Hind/AH’s GF5342, Hubbell’s GF 5352, Leviton’s 6899, Pass & Seymour’s 2091S, or Daniel Woodheads 5352GF. WEATHER RESISTANT GFCI RECEPTACLES ARE REQUIRED IN ALL WET AND DAMP LOCATIONS. G. Weather Resistant Ground Fault Interrupter Receptacles: 1.