220 psig to bar
[DOC File]Part 1 – General
https://info.5y1.org/220-psig-to-bar_1_1c5bd9.html
Configurable displays showing, bar graph and meter. Keypad with keys for Run/Stop, Local/Remote, Increase/Decrease, Reset, Menu navigation and Parameter select/edit. The control panel shall be removable, capable of remote mounting and allow for uploading and downloading of parameter settings as an aid for start-up of multiple VFDs.
SECTION 232116 - HYDRONIC PIPING SPECIALTIES
psig / 16 bar. Max Differential Pressure Rating (Minimum allowable): 51 psig . Operating Temperature Range: [14-248. deg F]. Include manufacturer’s optional capillary tube, drain and extension kits to ensure proper operation of installed valves.
[DOCX File]PART 1 – GENERAL - GoFog
https://info.5y1.org/220-psig-to-bar_1_368463.html
Median droplet size to be between 10-40 microns with 95% of the droplets at 15 microns or less at 1,000 psig (69 bar) operating pressure. The nozzle manifold to be constructed of ½”OD 316 stainless steel tubing with 0.035” wall thickness.
[DOC File]GENERAL
https://info.5y1.org/220-psig-to-bar_1_80039e.html
All coils shall be tested at 325 PSIG air pressure under water, and rated for a maximum 300 PSIG working pressure at 200°F. Coils shall be circuited for counter flow to maximize unit efficiency. All water coils shall be designed to connect with ½” nominal pipe connections. Coil Casing shall be fabricated from galvanized steel [stainless steel].
[DOCX File]SECTION 221100 - PLUMBING PIPING
https://info.5y1.org/220-psig-to-bar_1_c13b91.html
ASTM A666: Standard Specification for Annealed or Cold-Worked Austenitic Stainless-Steel Sheet, Strip, Plate, and Flat Bar. ASTM A743: Standard Specification for Castings, Iron-Chromium, Iron-Chromium-Nickel, Corrosion Resistant, for General Application.
SECTION 212200 - CLEAN-AGENT FIRE-EXTINGUISHING …
Specifier Note: IG-55 systems are usually 2900-psig (200 bar) or 4350-psig (300 bar) charging-pressure systems. Verify system charging pressure. Fittings Working Pressure: [2900 psig (19,996 kPa)] or [4350 psig (29,993 kPa)] minimum, upstream of the pressure reducer.
[DOCX File]SECTION 09 91 00 - PAINTING - Veterans Affairs
https://info.5y1.org/220-psig-to-bar_1_84a23c.html
a.Use 220-grit sandpaper. b.Sand sealers and varnish between coats. c.Sand enough to scarify surface to assure good adhesion of subsequent coats, to level roughly applied sealer and varnish, and to knock off "whiskers" of any raised grain as well as dust particles.
[DOC File]SECTION 238219 - FAN COIL UNITS
https://info.5y1.org/220-psig-to-bar_1_37b3ce.html
Hot Water Coil: Copper tube, with mechanically bonded aluminum fins spaced no closer than 0.1 inch and rated for a minimum working pressure of 200 psig and a maximum entering water temperature of 220°F. Include manual air vent and drain. CONTROLS. Fan and Motor Board: Removable.
[DOC File]Municipal Specification for Cerlic High Suspended Solids Meter
https://info.5y1.org/220-psig-to-bar_1_8fac66.html
Max. flush water pressure to be 90 psig (6 bar). Winch to have safety clutch to prevent major damage in case of probe being caught in the rake. Safety clutch to be adjustable from motor to winch drum. Probe speed to 5.7” per second. Sensor to have built-in tilt alarm, so sensor will return to home position, if it contacts the rake or any ...
[DOC File]Specification for ITXIL15/38 Inline Suspended Solids Meter
https://info.5y1.org/220-psig-to-bar_1_5e895b.html
The sensor housing is to be made of 316SS with glass lenses. Sensor designed for 90 psig (6 bar) working pressure and supplied with integral built-in mechanical stop. Sensor to have integral SS flushing nozzle with check valve. Sensor to be designed to mount in a 1.5” npt female connection on pipe. Gap between lenses is to be to be 15mm.