240 480 step up transformer
[DOC File]1 - Eaton
https://info.5y1.org/240-480-step-up-transformer_1_dfe8a4.html
Available up to 42 amps of full-load transformer current, up to 35 KV grounded wye, or 17.1 KV delta. The high-voltage overcurrent protection scheme provided with the transformer shall be a three-phase trip MagneX Interrupter. This externally resettable device may also be used as an on-off switch. The three-phase MagneX Interrupter shall be in series with ELSP under-oil partial-range current ...
[DOC File]DOUGLAS LOW VOLTAGE SPECIFICATION
https://info.5y1.org/240-480-step-up-transformer_1_94b24b.html
Double pole relays shall be rated and UL listed for 208, 240 or 480 VAC and CSA for up to 347 VAC lighting loads at 20 amps. Use Douglas WR-6172. The relays shall have a label indicating the short circuit fault current rating as per the NEC 2005. The single pole relays shall have passed U/L 508 short circuit tests at 14,000 amperes, the 2-pole ...
[DOCX File]Home - HYDMECH Band Saws, Cold Saws, Carbide Saws and ...
https://info.5y1.org/240-480-step-up-transformer_1_07bd28.html
2021-05-10 · 208*,240, 480, 575* v. Machine Weight . 6,172 lbs. Blade Speed. 49-380 (660*) SFM. Table Height. 34” Automatic Multi-indexing. 0-24” Dimensions (w x l x h) 88” x 63” x 78” *Optional Power transformer required. Standard Machine Features. Heavy-duty cast iron saw head. Spilt front vise. Cast iron shuttle features automatic multi-indexing up to 24” in a single stroke with automatic ...
[DOC File]TEMPLATE - Request for Quotation (00163422-14).DOC
https://info.5y1.org/240-480-step-up-transformer_1_959c65.html
Transformer – Copper – EVI Style – 25KVA – 240-480/240V, 1PH. 225A, 120/240V, 1PH, 3W 12CCT (Copper), C/W Branch Breakers (6-15A 1P) and (1-125A, 2P) GFI Duplex Receptacle. 100A, 240/480V, 1PH, 3W 18CCT (Copper) C/W Branch Breakers (1-15A 1P 10-20A 1P) Advance Protection SPD. 3 Positions Selector Switch . Contractors 20A 2P 240V Coils. 3 Terminal Blocks for Photocell, and 10 for …
[DOC File]Power Purifier Guide Specification
https://info.5y1.org/240-480-step-up-transformer_1_c12412.html
The nominal AC input voltage rating of the transformer shall be (120/208/240/480) (208/240/480) VAC, single phase, 60 hertz. Engineer’s reference: Units 500 VA to 5 KVA are available with an input nominal selection of 120/208/240/480 VAC. Units 8 KVA to 25 KVA are available with an input nominal selection of 208/240/480 VAC. If upstream ...
[DOC File]Introduction to Distribution Systems
https://info.5y1.org/240-480-step-up-transformer_1_7d4f09.html
120/240 single phase. 120/208 3 phase. 277/480 3 phase. The 120/240 configuration is obtained from the low-side of a HV/240 volt transformer, where HV is the rated voltage on the high voltage side, and the 240 is the rated voltage on the low voltage side. Then a center tap is connected to the low voltage winding and grounded along with the low ...
[DOCX File]PART 1 – GENERAL
https://info.5y1.org/240-480-step-up-transformer_1_da7e70.html
If shipping to Europe, transformer will carry a CE mark. If transformer is to be used for non-linear load applications, the transformer shall be de-rated as per ANSI/IEEE C57.110. Scott-T designs not acceptable. Voltage and . k. VA Requirements: Primary Voltage: Single Phase - [208], [240X480], [240], [277], [416], [480], [600], [other] Volts
[DOCX File]ATE1120: Electrical Fundamental-II
https://info.5y1.org/240-480-step-up-transformer_1_7ca118.html
The most common type of control transformer has two primary coils and one secondary coil, as shown in Figure 1.9. Figure 1.9: A Typical Control Transformer Configuration. In most cases, the control transformer is used to reduce the main or line voltage of 240 VAC or 480 VAC to a control voltage of 120 VAC. Notice that the primary windings are ...
[DOCX File]EXECUTION - Hammond Power Solutions
https://info.5y1.org/240-480-step-up-transformer_1_85e9bd.html
NEMA ST-20 Dry-Type Transformer for General Applications. IEEE C57.110 Recommended Practice for establishing transformer capability when feeding non-sinusoidal load currents. DOE 10 CFR Part 431 Efficiency Standards; published in the Federal Register on April 18, 2013, CSA C802.2 as referenced in the Canadian Energy Efficiency Act (SOR/94-651). UL 1561, CSA C9-02 and C22.2 No.47. Natural ...