250 urd wire

    • Quadruplex 600 Volt Underground Service Entrance - Southwire

      1. The actual number of strands may differ for single input wire per ASTM B901 Table 2 – Electrical and Engineering Data Stock Number Code Word Phase Cond. Size DC Resistance @ 25°C AC Resistance @ 90°C Inductive Reactance @ 60Hz GMR Allowable Ampacity in Duct 90°C Allowable Ampacity Directly Buried 90°C AWG/ Kcmil Ω/1000ft Ω/1000ft Ω ...


    • [PDF File]Secondary URD Aluminum, XLPE Insulated, 600 V - CME Wire

      https://info.5y1.org/250-urd-wire_1_195e71.html

      Secondary URD Aluminum, XLPE Insulated, 600 V, Ampacity Data Ampacity Data continued Cable Construction Single, 2PLX, 3PLX and 4PLX Conductor Size AWG/kcmil Ampacity 75 °C (167 °F) 90 °C (194 °F) 12 20 25 10 30 35 840 45 650 55 465 75 375 85 2 90 100 1 100 115 1/0 120 135 2/0 135 150 3/0 155 175 4/0 180 205 250 205 230 300 230 260 350 250 ...


    • [PDF File]Triplex Aluminum Conductor 600V URD - Priority Wire

      https://info.5y1.org/250-urd-wire_1_6ea9a8.html

      Triplex Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct. CONDUCTORS:


    • [PDF File]Underground Distribution Cable and Power Cable. - KA Factor

      https://info.5y1.org/250-urd-wire_1_5b3216.html

      Either the allowable fault current (I), the allowable duration of time (t), or the cross sectional area (A) of metal necessary to sustain a particular fault can be computed when two of the three variables are known. = k × A2 t


    • [PDF File]Quadruplex Aluminum Conductor 600V URD - Priority Wire

      https://info.5y1.org/250-urd-wire_1_c6075c.html

      Quadruplex Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can be provided pre-pulled into duct.


    • [PDF File]Secondary URD Aluminum - CME Wire

      https://info.5y1.org/250-urd-wire_1_7a5cf1.html

      CME Wire and Cable | 495 Horizon Drive NE, Suite 100, Suwanee, Georgia 30024 | www.cmewire.com | 770.623.0001 Secondary URD Cable – Aluminum Secondary URD Aluminum XLPE Insulated, 600 V


    • ALUMINUM WIRE & CABLE Aluminum URD

      Wire & Cable Company is indicative only and shall not be binding on Houston Wire & Cable Company or be treated as constituting a representation on the part of Houston Wire & Cable Company. All data subject to change without notice. See product application, construction, features, configurations and additional standards on page 18. 8 6 4 2 7 7 7 ...