3 phase 480 volt disconnect

    • [PDF File]SERVICE MANUAL - Vulcan Equipment

      https://info.5y1.org/3-phase-480-volt-disconnect_1_73fb3d.html

      Model AVAILABLE VOLTAGES - 208 OR 240 VOLT - 1 OR 3-PHASE, 480 VOLT - 3-PHASE Configuration Nominal AMPS Per Line Wire 3-Phase 1-Phase 208V 240V 480V X Y Z X Y Z X Y Z 208V 240V ... Disconnect the electrical power to the machine and follow lockout / tagout procedures. 1. Remove plug from the access hole in the oven control panel.


    • [PDF File]Product Catalog Electric Unit Heaters - Trane

      https://info.5y1.org/3-phase-480-volt-disconnect_1_9a973d.html

      or 480-volt operation. † One unit can be used for either horizontal or vertical discharge. † Specially designed inlet louvers, venturi and outlet diffuser provide uniform air temperature and throw characteristics. † Single-phase units, easily converted to three-ph ase power, are ava ilable in 3.3 to 10 kW for 208 and 240-volt operation.


    • [PDF File]Customer Guide for Electric Service for Ohio

      https://info.5y1.org/3-phase-480-volt-disconnect_1_8311f6.html

      3. 5 . Added for a customer-owned and installed underground service lateral, if a customer increases the service lateral length or load, the customer shall be responsible to verify that


    • IP20 & IP66 (NEMA 4X) - Inverter Drive

      Optidrive ODE-2 User Guide Revision 3.30 www.invertekdrives.com 1 1 on User Guide IP20 & IP66 (NEMA 4X) AC Variable Speed Drive 0.37 – 11kW (0.5 – 15HP) 110 – …


    • [PDF File]Electric Service Handbook - Tacoma Public Utilities

      https://info.5y1.org/3-phase-480-volt-disconnect_1_9f3268.html

      For work on existing services, upon request, Tacoma Power will disconnect power to enable you to work on a de-energized service. Caution: oing live line work on the customerD side of ... • 120/208 volt, 3- phase, 4 wire wye • 277/480 volt, 3- phase, 4 wire wye • 120/208 volt, 2- phase, 3 wire • 125/216 volt, (Downtown Network ...


    • [PDF File]Heavy Duty Safety Switch Standards and Ratings

      https://info.5y1.org/3-phase-480-volt-disconnect_1_03a3ec.html

      Jul 23, 2019 · 1-Phase, 2-Wire 3-Phase, 3-Wire Std. Max. Std. Max. Std. Max. Std. Max. 600 Volt Fusible 2-Pole, 2-Fuse 480 Volt AC/600 Volt AC/600 Volt DC 0030 HF261 015 HF261R 015 03 071⁄ 2 — — 03 10 — — 05 15 0060 HF262 020 HF262R 020 05 20 — — 10 25 — — 10 30 0100 HF263 026 HF263R 027 10 30 — — 15 40 — — 20 50 3-Pole, 3-Fuse 480 ...


    • [PDF File]Short Circuit Current Calculations - Eaton

      https://info.5y1.org/3-phase-480-volt-disconnect_1_dec3c8.html

      Step 3. Determine by formula or Table 1 the transformer let-through short-circuit current. See Notes 3 and 4. Note 3.Utility voltages may vary ±10% for power and ±5.8% for 120 Volt lighting ser-vices. Therefore, for highest short circuit conditions, multiply values as calculated in step 3 by 1.1 or 1.058 respectively.


    • [PDF File]Customer Guide for Electric Service for WV

      https://info.5y1.org/3-phase-480-volt-disconnect_1_675f4d.html

      Three-Phase Transformer Pre-Cast Concrete Foundation (3 pages) ..... Exhibit 25 Concrete Flat-Pad Foundation Pad-Mounted Transformer 75 to 500 kVA Three-Phase,


    • [PDF File]Section 5 Meters and Service Entrance Equipment

      https://info.5y1.org/3-phase-480-volt-disconnect_1_b17014.html

      208/120 Volt 4-Wire 3Ø Wye 480/277 Volt 4-Wire 3Ø Wye 8" Min. 7 Terminal Safety Socket Neutral Bonded In Meter Socket Code White or Gray Ground per NEC Neutral Wire Code White or Gray Mounting Height 4' Min. to 6' Max. Note - Conductor Color Coding: Each phase conductor shall be identified per NEC. The neutral shall be white or gray. Figure 5-4


    • [PDF File]IC Catalog - Section 17 - Circuit Breakers

      https://info.5y1.org/3-phase-480-volt-disconnect_1_fe019a.html

      Jul 23, 2019 · 3- & 4-pole up to 150A for circuit protection up to 600Y/347 volt circuits (UL/CSA/IEC) 3VA53 Breakers Selection and ordering data UL Type 480V 600V MJAS 35KAIC 18KAIC HJAS 65KAIC 25KAIC CJAS 100KAIC 35KAIC 2(3)-, 3- & 4-pole up to 400A for circuit protection up to 600 volt circuits (UL/CSA/IEC) Information Page Breakers 17/22 – 17/23