The panel will be provided with a key lock and handle to prevent access by unauthorized personnel. The main power supply to the boiler shall be _____ (208, 240, 380, 480) volts, 3 phase, (50, 60) Hertz, (3) three-wire system supplied to the main distribution lugs in the electrical panel.
[DOC File]PART 1
https://info.5y1.org/3-phase-electrical-panel-box_1_dc0b63.html
AIR TERMINAL UNIT (VAV BOX) Provide medium pressure, single duct, pressure independent variable air volume (VAV) box of 277V/1 Phase electrical service. VAV box shall contain a normally open volume damper assembly inside unit casing and electric heat of the …
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/3-phase-electrical-panel-box_1_7ba407.html
The main breaker in the panel serves as a single point to shut power off for the entire building. Remotely Located Panels from a Main Panel. 1.2., & 3 of single panel service apply to the main panel. The subfed conductors and the circuit breakers in the main panel are sized to the ampacity rating of …
[DOC File]PSG Section 16470S - Electrical and Industrial
https://info.5y1.org/3-phase-electrical-panel-box_1_eaaaba.html
Enclosures shall be at least 20 inches wide made from galvanized steel. Provide minimum gutter space in accordance with the National Electrical Code. Where feeder cables supplying the mains of a panel are carried through its box to supply other electrical equipment, the box shall be sized to include the additional required wiring space.
[DOC File]16075 - Electrical Identification
https://info.5y1.org/3-phase-electrical-panel-box_1_be79f7.html
.3 Colour coding shall be in accordance with Canadian Electrical Code, and as follows: Voltage. Colour .1 120/208 V, 3 phase: Red, black and blue. .2 120/208 V emergency: Red, black and blue with yellow tracer. .3 347/600 V 3 phase: Orange, brown and yellow. .4 347/600 V emergency: Orange, brown and yellow with red tracer.
[DOC File]26 05 53 (16075) - Identification for Electrical Systems
https://info.5y1.org/3-phase-electrical-panel-box_1_fe4d52.html
.3 Colour coding shall be in accordance with Canadian Electrical Code, and as follows: Voltage. Colour .1 120/208 V, 3 phase: Red, black and blue. .2 120/208 V emergency: Red, black and blue with yellow tracer. .3 347/600 V 3 phase: Orange, brown and yellow. .4 347/600 V emergency: Orange, brown and yellow with red tracer.
CHAPTER 9 - ELECTRICAL
Nov 25, 2015 · The circuit breaker for the SPD shall be located in the main panel or main switchboard as close as possible to the incoming feed for most effectiveness. For example, a 3 phase service with the incoming feed at the top of the panel bus, it shall be located in the 1, 3, 5 or the 2, 4, 6 pole position.
[DOC File]ELECTRICAL DESIGN CRITERIA
https://info.5y1.org/3-phase-electrical-panel-box_1_9a2dbe.html
Equipment included in this analysis shall include all 3 phase equipment including transformers, switchgear, panelboards, switchboards, motor control centers, disconnect switches, and their respective circuit protective devices such as circuit breakers, fuses and relays for all portions of the electrical system from the primary protective device ...
[DOC File]Control of Hazardous Energy: Equipment-specific Lockout ...
https://info.5y1.org/3-phase-electrical-panel-box_1_3e55b9.html
Electrical- low voltage (50-600 V) - list amperage 480VAC 3 phase 100 amp service Wiring connection points in motor housing junction box Disconnect adjacent to motor on right hand side. Section D: Preparation and Notification. Step 1, Preparation: Identify group lockouts, authorized personnel, and …
[DOC File]SECTION 260519 - LOW-VOLTAGE ELECTRICAL POWER …
https://info.5y1.org/3-phase-electrical-panel-box_1_7b7ff5.html
480/277V 208/120V 240/120V Phase A Brown Black Black Phase B Orange Red Red Phase C Yellow Blue -- Ground Green Green Green Neutral Gray White White or Gray* * If installed with 480/277V or 208/120V in the same raceway, box, gutter, or other enclosure, 240/120V neutral conductor color shall differ from the other system neutral conductor per NEC ...