3 phase hp to kw
[DOC File]Home | US Forest Service
https://info.5y1.org/3-phase-hp-to-kw_1_05079f.html
Jun 17, 2002 · 120/208V, 3 phase, 4W- This is a good choice for a three phase system because you can balance 120 volt loads around the wye to equally load the generator. 208V single phase and 208V three phase loads can be used as well as 120V single phase loads.
[DOCX File]Section 23 05 12 - GENERAL MOTOR REQUIREMENTS FOR …
https://info.5y1.org/3-phase-hp-to-kw_1_bc5411.html
Motors, less than 373 W (1/2 hp): Single phase. Motors, 373 W (1/2 hp) and larger: 3 phase. Exceptions: Hermetically sealed motors. Motors for equipment assemblies, less than 746 W (1 hp), may be single phase provided the manufacturer of the proposed assemblies cannot supply the assemblies with three phase …
[DOCX File]COMMERCIAL / INDUSTRIAL CUSTOMER INFORMATION SHEET
https://info.5y1.org/3-phase-hp-to-kw_1_090496.html
Service Description. Desired Secondary Voltage: 3 Phase 120/208v 3 Phase 277/480vNote: Not all voltages may be available 1 Phase 120/240v 1 Phase 120v Only Other . Panel Size (in Amps): Total number of 3 Phase meters: ≤ 200 A > 200 A . Total number of 1 Phase meters: ≤ 400 A > 400 A
[DOCX File]Motor Drive System Assessment
https://info.5y1.org/3-phase-hp-to-kw_1_ea9c64.html
The best way to determine motor power consumption is with a power meter. Power meters simultaneously measure the current, voltage and power factor and combine these measurements to determine power. For a three-phase motor, the power consumption is: Power (kW) = Average Current of 3 Phases (A) x Voltage (V) x
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/3-phase-hp-to-kw_1_7ba407.html
If more than 3 phase wires are in one conduit, then wires must be derated according to Note 8, after Table 310-19 as follows: TABLE 1. Number of Conductors Percent of Values in 310-16 *1-3 80 *4-6 80. 70 25-42 60. 43 and above 50 *If circuit is loaded up to 80% ampacity, then 6 phase …
Application 3PH Service - PPL Electric
3-PHASE, 7,200/12,470 VOLT, 4-WIRE . 3-PHASE, 120/208 VOLT, 4-WIRE 3-PHASE, 69,000 VOLT or HIGHER ... Please indicate connected loads in terms of kW, HP and Tons. If this information is missing or incomplete, your application will not be processed and could cause delays in …
[DOC File]2003 WATERPRO - Grundfos
https://info.5y1.org/3-phase-hp-to-kw_1_c023f2.html
Nov 02, 2010 · _____kW (_____ hp) submersible electric 3-phase motor prepared for operation at _____ volts. ... Bearings shall be designed for a nominal L10 life time of 25000 hr to and below 152 kW and. 50000 hr above 152 kW at best efficiency point. ... phase) and one or two moisture switches (placed in the terminal box and stator housing. ...
[DOC File]Industrial & Commercial Services
https://info.5y1.org/3-phase-hp-to-kw_1_4e9a0d.html
Please indicate connected loads in terms of kW, HP and Tons. ADDED REMOVED Lighting Indoor kW kW Outdoor kW kW 1-Phase Miscellaneous kW kW 1-Phase Motors (excludes HVAC) HP HP 3 Phase Motors (excludes HVAC) HP HP 3-Phase Miscellaneous* kW kW *Specify Equipment: Cooking kW kW Water Heating kW kW Process Heating kW kW Refrigeration kW kW