30 amp 3 pole disconnect
[DOC File]PSG Section 26 28 16.13 - Eaton
https://info.5y1.org/30-amp-3-pole-disconnect_1_b52be5.html
30 to 1200 amperes. 250 volts ac, dc; 600 volts ac (30 A to 200 A 600 volts dc) 2, 3, 4 and 6 poles (2, 3 and 4 poles on 800 A; 2 and 3 poles on 1200 A) Fusible and non-fusible. Mechanical lugs suitable for aluminum or copper conductors. Construction. Switch blades and jaws shall be visible and plated copper
[DOC File]SECTION I - OAS
https://info.5y1.org/30-amp-3-pole-disconnect_1_e89464.html
The main disconnect is a very important safety device for the home, as it allows the power to be quickly shut off in case of fire or emergency. ... Water heater (large): 30 amps 2 pole #10 three core + ground. Water heater (small): 20 amps 1 pole #12 two core + ground ... single outlet for the washing machine and one 20 amp duplex outlet for ...
[DOCX File]ARCAT | Free Building Product CAD Details, BIM, Specs and …
https://info.5y1.org/30-amp-3-pole-disconnect_1_e287fe.html
Permanent 220 VAC, 40 amp single phase power or 208 VAC, 30 amp, 3 phase power to operate lift from lockable fused/cartridge type disconnect switch with auxiliary contacts for battery operation. 110 VAC, 15 amp single phase power to operate lighting circuit.
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/30-amp-3-pole-disconnect_1_7ba407.html
Load: Unit Heater 10 KW, 230V, 3 phase, find I, wire size, circuit breaker size. Conduit Size. I = 10 KW = 25.1 Amp .23 KV (3. Wire Size- 25.1A = 31.3 Amp.8 NEC 310-16 Use #8 good for 45 amp, 3 #8 + 1 #8 ground in 1" RGC Table 3A . Circuit Breaker = 25.1A = 31.3 Amp so use 35A.8 Conduit Size if different size wires are used
[DOC File]PSG Section 16441A - Eaton
https://info.5y1.org/30-amp-3-pole-disconnect_1_b92f43.html
250 volts ac, dc; 600 volts ac (30 A to 200 A 600 volts dc) 2, 3, 4 and 6 poles (2, 3 and 4 poles on 800 A; 2 and 3 poles on 1200 A) Fusible and non-fusible. Mechanical lugs suitable for aluminum or copper conductors. Construction. Switch blades and jaws shall be visible and plated copper
Architect’s and Engineer’s Specifications
Code Description D1 Disconnect Switch, 600V, Three-pole, 40 Amp D2 Disconnect Switch, 600V, Three-pole, 80 Amp D3 Disconnect Switch, 277V, Double-pole, 20 Amp R1 24 Volt Relay (2) R2 24 Volt Relay with Transformer (2) S3 Fan On/Auto Switch (2) A built-in thermostat will not be supplied when option “R1” or “R2” are selected.
[DOCX File]ARCAT | Free Building Product CAD Details, BIM, Specs and …
https://info.5y1.org/30-amp-3-pole-disconnect_1_619a77.html
AC Manual Motor Controller, Toggle Switch, 30 Amp, 600V (MS30x Series), Suitable as Motor Disconnect, NEMA enclosure 1, 3R and 4X available. AC Manual Motor Controller, Toggle Switch, 40 Amp, 600V (MS40x Series), Suitable as Motor Disconnect, NEMA 4X enclosure available. ... 30 Amp-600 VAC / 20 Amp-250 Volt DC 3-Pole 4-Wire Grounding. Locking ...
[DOC File]BID CLOSING DATE: 30 December 2009
https://info.5y1.org/30-amp-3-pole-disconnect_1_5ac7ef.html
d42f, sn-12826 28 4 no breaker, circuit, 225 amp, 3 pole, 600 volts tfj 236 g.e. 29 6 no protector- motor circuit, series - c, 3 pole, 150 amp, 600 vac, "cutler hammer" hmcp150t4c hhcp150t4 30 2 no overload, magnetic contactor 200 amp 24178010551 lh200dc0 31 4 no transformer-" impervitran " control power- 150va., 230/460 vac.
BAI Model: 909U (Flat Top) - INDEECO
Code Description D1 Disconnect Switch, Three-pole, 600V, 40 Amp F Front Air Outlet (BAI Only) R1 24V Relay, 240V, 22 Amp; 277V, 19 Amp R2 24V Relay with Transformer, 240V, 22 Amp; 277V, 19 Amp R3 24V Double Pole Relay, 240V, 25 Amp; 480V, 12.5 Amp R4 240V Relay, Single-pole, 240V, 25 Amp; 480V, 12.5 Amp R5 240V Relay, Double-pole, 240V, 25 Amp ...
[DOCX File]Surface Switch: .com
https://info.5y1.org/30-amp-3-pole-disconnect_1_c13d42.html
Iron Clad Double Pole main switch is used in single-phase supply circuits. These are available in 15 Amp, 30 Amp, 60 Amps and 100 amperes current rating. In these switches, either two numbers of fuse links are provided or a fuse link and a neutral link is provided.