30 amp 600v fusible disconnect

    • Are there any 1000 VDC fusible disconnect versions available?

      Currently there are no 1000 Vdc fusible disconnect versions available at 100 A and below. S1 S1 S2 S2 – S1 + S1 S2 S2 – + ––+ Note: Majority of grounded configurations have isolated return terminals. For specific circuit configurations available, please see matrix in the middle of page 4. –+–+S3L


    • What type of HVAC disconnects are available in NEMA 3R enclosures?

      Fused and non-fused HVAC disconnects Fused and non-fused pullout HVAC disconnects in NEMA 3R enclosures. Fused versions are available in 30 and 60 amp ratings with or without self- testing GFCI receptacles. Non-fused versions are available in 60 amp versions with or without self- testing GFCI receptacles.


    • Can a selector handle be used with a fusible switch over 30A?

      NOTE: Selector handles are not recommended for use with fusible switches over 30A. The OS30_ switch has a TEST position, accessed by rotating the mechanism 45 degrees counterclockwise from the OFF position. In the TEST position, optional auxiliary contacts, OA4B1C, are actuated but the main switch contacts are not.


    • What is the mounting depth of a disconnect switch?

      Mounting depth is distance from the outside of the door to the disconnect switch mounting plate. Shaft can be cut to desired length. Not suitable for use on cable operated flange version of OS100. Suitable for 1 or 3 phase circuits. Includes 1 N.O. and 1 N.C. auxiliary contacts and red & green LED lights for indication.


    • [PDF File]Product data sheet H361 - Schneider Electric

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_da4e2d.html

      Fusible disconnect Short-circuit current 200 kA R, J or L 10 kA H or K Device mounting Surface Number of poles 3 Electrical connection Lugs Series name Heavy duty System Voltage 600 V AC/DC AWG gauge 14...6 AWG copper 12...6 AWG aluminium Ordering and shipping details Category 00008 - H&HU, 2&3P, N1, 30-200A Discount Schedule DE1 GTIN ...


    • [PDF File]Hubbell Circuit-Lock Motor Disconnects

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_a7cd47.html

      Fused Disconnect Switches 3 Pole 600V AC Amp Description Catalog Number 30 Circuit-Lock fused disconnect switch FDS30* 60 Circuit-Lock fused disconnect switch FDS60* Auxiliary contact, normally open, A600 pilot duty HBLACFSNO Auxiliary contact, normally closed, A600 pilot duty HBLACFSNC Note: *Class "J" fuse not included. • UL 98 Rated Switch


    • [PDF File]Fusible disconnect switches Disconnect switches

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_0b27d1.html

      Standard part number designation 1 Fusible OS Switches (30 to 60A) OS 30 F A J 22 F Amperage 30 = 30 amps 60 = 60 amps Fusible Fuse Type/Class = Class J fuse compatible CC= Class CC fuse compatible Number of poles and placement of the mechanism 12 = 1 Pole to the left of mechanism, 2 poles to the right of mechanism


    • [PDF File]GE Disconnect Quick Selection Guide - USESI Careers

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_406b67.html

      GE Disconnect Quick Selection Guide General & Heavy Duty Disconnects (240V & 600V) through 600A Duty Volts Fusible or Non-Fusible Poles Amperage Indoor Type 1 Enclosure Outdoor Type 3R Enclosure Indoor / Outdoor Neutral Stainless Steel Type 4X Enclosure Stainless Steel Neutral General 240V Fusible 2 30 TG3221 TG3221R Included See Heavy Duty for


    • [PDF File]Product Data Sheet H361RB - RENVU

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_6b2f82.html

      Maximum Voltage Rating 600V Short Circuit Current Rating 10kA (Class H or K) - 200kA (Class R or J) Number of Poles 3-Pole Disconnect Type Fusible Terminal Type Lugs Type of Duty Heavy Duty Wire Size #12 to #6 AWG(Al) or #14 to #6 AWG(Cu) Technical Characteristics Category 00009 - Safety Switch, Heavy Duty, 2 & 3 Pole, 30-200 Amp, Outdoor


    • [PDF File]DC Disconnects - 600Vdc and 1000Vdc - product brochure - Eaton

      https://info.5y1.org/30-amp-600v-fusible-disconnect_1_6592f9.html

      • Fusible and non-fusible • Grounded configurations include isolated return terminals. Exceptions include 6-circuit 30, 60, 100 A and 4-circuit 400 A • Suitable for use on a circuit capable of delivering up to 10,000 A, 600 Vdc 1000 Vdc specifi c features • 1-, 2- and 3-circuit configurations for both grounded and ungrounded systems A