400 amp meter base
PSG Section 26 24 13.17 - Eaton
Meter Sockets. Ringless-type rated 200-Amp or 400-Amp (Rated 320 A continuous) 400-Amp continuous bolt-on meter sockets. Manual bypass. Individual compartments with covers and sealing provisions. Transformer rated sockets for 400-Amp and larger circuits with breaker tenant main or fusible switch tenant main, hot or cold sequence (Internal wire ...
[DOCX File]IFS switchboard guide spec - Eaton
https://info.5y1.org/400-amp-meter-base_1_288abc.html
The Switchboard shall accommodate two (2) 42-circuit panelboards (225-Amp Main Circuit Breaker or 400-Amp Main Lug Only) per structure, or one, half-height molded case breaker distribution chassis and one (1) 42-circuit panelboard.
[DOC File]RESIDENTIAL SERVICES
https://info.5y1.org/400-amp-meter-base_1_8a8fba.html
Surface NA NA Flush NA NA 400 Amp Meter Socket & Circuit Breaker Combination, Underground Only. Surface BY1451GL. BY1455GL NA Flush JC0404L1400FDS. JA0816B1400FDS. JA3042B1400SDS JA3042B1400FDS NA. ... Requires ANSI detachable type meter socket--no A-base or K-base sockets.
REQUEST FOR QUOTATION (RFQ) - UNDP Procurement
A.C. Welding transformer set single ph ac supply, 50 Hz, 220 v, 400 amp air cooled – Confirming I.S.- 1851/1997 with current regulator suitable for manual arc Welding. The primary winding of the transformer shall be provided with tapping to compensate for variation in the input supply mains.
[DOCX File]BOONE COUNTY FIRE PROTECTION DISTRICT
https://info.5y1.org/400-amp-meter-base_1_92561b.html
Mar 16, 2016 · A motion was made by Board Member Schnarre to authorize Change Order #2 for the install of meter base and feeder cables for 400 amp service provided by Boone Electric to Stations 3, 6 and . 10 for Phase 1 projects upon review and approval by Attorney Parshall and authorize the Chairman to sign same. Motion seconded by Board Member Shorr.
[DOC File]GENERIC SPEC FOR MULTIFUNCTION ELECTRICAL POWER …
https://info.5y1.org/400-amp-meter-base_1_987a5a.html
The sub-meter shall provide sampling at 400+ samples per cycle on all channel measured readings simultaneously. The sub-meter shall utilize 24 bit Analog to Digital conversion. Sub-meter shall provide Harmonics %THD (% of total Harmonic Distortion). C. The sub-meter shall include a three line, bright red, .56” LED display.
[DOC File]Industrial & Commercial Services
https://info.5y1.org/400-amp-meter-base_1_1e4207.html
SELF CONTAINED (required for 120/240 and 120/208 volt up to and including 600 amp, and 277/480 volt service up to and including 400 Amp svc.) CT CABINET SWITCHGEAR (drawing showing dimensions for termination and metering compartment required)
[DOC File]E-Mon D-Mon BACnet, ModBus, and LonWorks Point Maps
https://info.5y1.org/400-amp-meter-base_1_8c087f.html
Table 1 E-Mon Class 1000 & 2000 Meter Size Pulse Value Guide 25 Amp 50 Amp 100 Amp 200 Amp 400 Amp 800 Amp 1600 Amp 3200 Amp Base Watt Hour Value per Pulse for legacy E-Mon meters* (serial numbers starting with 1203XXXX and earlier) 7.8125 15.625 31.25 62.50 125.00 250.00 500.00 1000.00 Base Watt Hour Value per Pulse* (serial numbers above ...
[DOCX File]Colorado City, Texas
https://info.5y1.org/400-amp-meter-base_1_038189.html
(1)Base permit fee $10.00 (2)Meter loop. Up to 2oo amp $15.00. For 225 to 400 amp $16.50. For anything over 400 amp $22.00 (3)Switches, outlets and lights. For 5 and less$5.00. 6 through 500 then$0.25 for each. 501 and more$0.15 for each (4)Reinspection (Charged after 2nd failed inspection)$25.00 (C) Plumbing Permit Fees- Section 3.04 (1)Base ...
[DOCX File]RIVIERA UTILITIES
https://info.5y1.org/400-amp-meter-base_1_014214.html
Identify 400 amp meter – single phase or three phase. Terminate underground secondary service in a meter base & perform the 9 step test. Identify all labeling and tags on a padmount transformer, primary and secondary. Be able to follow the instructions on a work order.