480 to 380 transformer

    • [DOC File]3ph transformer Dimensions.cdr - Camax

      https://info.5y1.org/480-to-380-transformer_1_504ee3.html

      kVA w h d fw fd kg 50va 150 150* 100 115 50 2.2 150va 150 155* 110 115 560 4.5 500va 180 170* 130 115 80 10.8 1kva 270 230* 150 150 80 15.5 2kva 270 230* 170 150 100 22.3 3kva 300 280* 170 150 100 34.7 4kva 300 280* 180 150 110 40.1 5kva 300 280* 190 150 120 46.3 6kva 300 280* 200 150 130 51.6 7.5kva 300 280* 210 150 140 57.9 10kva 360 400 240 ...

      480 220 transformer 3 phase


    • [DOC File]PRODUCT SPECIFICATION FOR A 15 TO 75 KVA,

      https://info.5y1.org/480-to-380-transformer_1_d9eb17.html

      The transformer core clamp shall be grounded to the frame through a 1" copper strap. The Transformer insulation system shall be 220° C. ... 50, 75 (100 kVA, 380 or 480 VAC input only) 2. Input Voltage: 380 or 415 VAC. 3. Output Voltage: 380y/220 or 415y/240. 4. Input Frequency Tolerance: 50 Hz ± 3 Hz. 5.3 Transformer. 1. Type: Dry, isolation ...

      480v to 380v transformer


    • Class I, Divisions 1 & 2, Groups C & D

      2. Unit heaters shall have an automatic and a manual reset thermal cutouts for overtemperature protection, controlling magnetic contactor and 24 volt control circuit transformer housed in a NEMA 7, 9 cast aluminum enclosure. 3.

      380 volt 3 phase transformer


    • [DOC File]PART 1 – GENERAL

      https://info.5y1.org/480-to-380-transformer_1_8ce7e6.html

      The transformer shall carry a 10 year limited warranty. (For details refer to the manufacturer’s published warranty) PRODUCTS. General construction: All single phase and three phase transformers shall be encapsulated type. The primary side of each transformer shall, if applicable, be provided with taps that meet or exceed NEMA standards.

      line transformers 480 to 220


    • [DOC File]USER REQUIREMENTS TEMPLATE - PHARM COMMUNITY

      https://info.5y1.org/480-to-380-transformer_1_2f8fd9.html

      440-480 volt, 3 phase, 60 Hz delta with ground. 208 volt, 3 phase, 60 Hz with ground. 120 volt, 1 phase, 60 Hz with ground. If a source other than listed above is required, the transformer must be supplied in the controls. The compressed air services available are: 90-100 PSI compressed air, dried and oil less.

      220 to 380 volt transformer


    • [DOCX File]1.01 - Electrical and Industrial | Power management solutions

      https://info.5y1.org/480-to-380-transformer_1_e67c1f.html

      Nominal three phase input voltage: 380/220Vac, 400/230Vac, or 415/240Vac. Operating input voltage range: +10%, -10% of average nominal input voltage without battery discharge. Note the UPS shall “power share” with the battery to -30% of nominal voltage, at full rated load.

      380v 3 phase transformer


    • [DOC File]Hammond Power Solutions

      https://info.5y1.org/480-to-380-transformer_1_c1b120.html

      Handle transformer using proper equipment for lifting and handling. WARRANTY. The transformer shall carry a 15 year limited pro-rated warranty. (For details, refer to the manufacturers published warranty) PRODUCTS. General construction: Single phase general purpose industrial control transformers shall be …

      380 volt transformers


    • [DOC File]Functional Specification for Single-Phase Overhead Type ...

      https://info.5y1.org/480-to-380-transformer_1_4537cd.html

      The transformer shall be designed in accordance with this specification and shall have an Average Winding Rise (AWR) of one of the following: ... 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Low-voltage rating of 120/240 volts or 240/480 volts is suitable for series, multiple, or three-wire service. ... 30 - 10 6 45 - 15 13 60 - 21 20 75 - 27 24 95 255 (10 ...

      480 to 220 transformer


    • [DOC File]PRODUCT SPECIFICATION FOR A 15 TO 500 KVA,

      https://info.5y1.org/480-to-380-transformer_1_80b17e.html

      The transformer shall be cooled by convection method and protected against thermal overload. The unit shall be . provided with an alarm contact to notify personnel should the transformer coil reach 140° C. A second contact. shall be provided to notify personnel should the transformer coil reach 160° C.

      480 220 transformer 3 phase


    • [DOCX File]Home - HYDMECH Band Saws, Cold Saws, Carbide Saws and ...

      https://info.5y1.org/480-to-380-transformer_1_07bd28.html

      May 10, 2021 · 208*,240, 480, 575* v. Machine Weight. 6,172 lbs. Blade Speed. 49-380 (660*) SFM. ... Power Transformer- change in house power from 240 v to 208 v-$1,600. Power Transformer- change in house power from 480 v to 575 v-$1,600. Short remnant – reduces remnant to 0.98”** ...

      480v to 380v transformer