480 to 400 vac transformer
[DOC File]PRODUCT SPECIFICATION FOR A 15 TO 300 KVA,
https://info.5y1.org/480-to-400-vac-transformer_1_9d144c.html
b) 400 to 1250 kVA: Buck-Boost Transformer. A multi-shield, convection cooled, 3 phase, buck-boost transformer shall be provided. Construction of the transformer should separate the primary connections and the secondary connections by placing them on opposite sides of the core.
[DOC File]1
https://info.5y1.org/480-to-400-vac-transformer_1_d7910f.html
Solid Core CTs up to 400 Amps is supplied with this meter. The LX 400 Amp CT works in a range of 4 to 400 Amp. The solid core CTs are more accurate than the split core and are much smaller. Split Cores are available if the power cannot be turned off. The (H1) or white dot, depending on the manufacture, faces the line side of the service.
[DOC File]Specifications for RMTD Model 2000 - Russelectric
https://info.5y1.org/480-to-400-vac-transformer_1_92c5db.html
Minimum UL listed close and withstand ratings at 480 VAC shall be as follows: Current Size Amps 3 Cycle Limiting Fuses 100 – 400 42 Ka 200,000 Ka
[DOC File]BASIC NEC CODE RULES AND DESIGN PRACTICE
https://info.5y1.org/480-to-400-vac-transformer_1_7ba407.html
500 2-250 MCM Parallel 400. 600 3-3/0 Parallel 480. 700 3-4/0 Parallel 560. 800 3-300 MCM Parallel 640 ... All the buildings served by a common transformer must be reevaluate to insure that the. existing short circuit protection is adequate for the larger transformer required when additional buildings are added to the compound service system ...
[DOC File]ACS800 ULH Product Overview
https://info.5y1.org/480-to-400-vac-transformer_1_e6089f.html
Peak Overload Capacity Imax (400 Vac and 500 Vac) (at least 10 seconds at start) Field Weakening Point 8 to 300 Hz. Switching Frequency 3 kHz (average), DTC dynamically varies from 1 to 12kHz. Acceleration & Deceleration Time 0.00 to 1800 Sec. Efficiency 97% at nominal power level. Short circuit withstand rating 65,000 AIC (UL) R2-R8; U31 ...
[DOCX File]PSG Section 16280B - Eaton
https://info.5y1.org/480-to-400-vac-transformer_1_a46a75.html
The nominal AC output voltage rating of the power conditioning transformer shall be (208 VAC) (400 VAC) (460 VAC) (480 VAC) (600 VAC) wye derived, 60 hertz. The output impedance of the power conditioning transformer shall be 2% to 3.5% typical.
[DOCX File]ULTRA-K 600K-he 3 Ph Guide Specification
https://info.5y1.org/480-to-400-vac-transformer_1_116d33.html
The nominal AC output voltage rating of the power conditioning transformer shall be (208 VAC) (400 VAC) (460 VAC) (480 VAC) (600 VAC) wye derived, 60 hertz. The output impedance of the power conditioning transformer shall be 2% to 3.5% typical.
[DOCX File]ATE1120: Electrical Fundamental-II
https://info.5y1.org/480-to-400-vac-transformer_1_7ca118.html
In most cases, the control transformer is used to reduce the main or line voltage of 240 VAC or 480 VAC to a control voltage of 120 VAC. Notice that the primary windings are crossed. This is done so that metal links can be used to connect the primaries for either 240 or 480 VAC operation, as shown in Figure 1.10.
[DOC File]MPA-460 ANF3/8031 BRUSHLESS SERVO AMPLIFIER
https://info.5y1.org/480-to-400-vac-transformer_1_8b8be8.html
A 50 to 100 VA rated transformer that operates from either a 240 or 480 Vac input would be sufficient. A. The separated supply is returned to ground through the amplifiers internal connection. The ac line source for the amplifier should be bonded to earth ground. B. This is a class 2 circuit that can only supply 100 VA max. C. The wiring for ...
[DOC File]400 & 500kVA SG Series UPS with eBoost Technology - UL listed
https://info.5y1.org/480-to-400-vac-transformer_1_249d43.html
1. Voltage: 480 VAC ±10% adjustable. Bypass Source, 3Ph, 4-wire + ground. (Consult factory for 3-wire installation, where neutral is not available). 2. Frequency: 60 Hz ± 3Hz. 3. Transfer time