The sprinkler shall be of a pop-up design with an overall height of 11 5/8” (295mm), a compartment cover diameter of 75/8 ” (194mm), a cap diameter of 3 5/8” (92mm) and a pop-up stroke of 4 3/16” (106mm). The sprinkler shall have a 1½” (40mm) ACME female-threaded inlet.
[DOCX File]23 11 00 - DOA Home
https://info.5y1.org/5-8-11-thread-specs_1_56f8b1.html
23 11 00-1 [DFD Master Spec] 15060B-1 . SECTION 23 11 00. ... use only long radius elbows having a centerline radius of 1.5 pipe diameters. ... Use a Teflon based thread lubricant or Teflon tape when making joints; no hard setting pipe thread cement or caulking will be allowed.
[DOCX File]SUBSAFE FUNCTIONAL AUDIT GUIDE
https://info.5y1.org/5-8-11-thread-specs_1_f6aa6c.html
5/13/11. Update to reflect initial usage corrective actions. 5/27/11. Updated to reflect comments from Assessment Team. 1/12/12. Updated to reflect comments from initial assessments conducted at all SUPSHIP sites. 8/17/12. ... Pull each thread until you are completely satisfied, or you have identified a …
[DOCX File]OUTLINE SPECIFICATION - United States Army
https://info.5y1.org/5-8-11-thread-specs_1_e2b02e.html
Air content for normal weight concrete shall be determined in accordance with ASTM C231. Lightweight concrete in the floor framing parts of the structure shall be air-entrained with a total air content of 4.5 to 7.5 percent, except that if the nominal maximum size coarse aggregate is 3/8 inch or less, the air content shall be 5.5 to 8.5 percent.
[DOC File]Evaluation of KME Type 3 Engine Model 326
https://info.5y1.org/5-8-11-thread-specs_1_8b9a69.html
Sep 29, 2010 · 10. Screens were not installed on the No. 8 (overboard suction) and No. 13 (gravity drain) valves. Both the Forest Service Specification and NFPA Standard 1906 require a screen in the inlet valves to the pump and tank. 11. The hose thread on the hose reel was NH. A NPSH hose thread adapter was added to the hose outlet.
[DOCX File]Wisconsin Department of Administration
https://info.5y1.org/5-8-11-thread-specs_1_a3110b.html
27 11 00 - 8. SECTION 27 11 00. COMMUNICATIONS EQUIPMENT ROOM FITTINGS. ... Per EIA/ECA-310 (5/8"-5/8"-1/2") Rear – 3-inch intervals to accept cable brackets. Channel Uprights shall be marked with Rack Unit (RU) identifiers per ANSI/TIA-606-B. Numbering shall be “bottom-to-top” (e.g. “#1” at bottom of rack). ... Use thread-forming ...
[DOCX File]Section 095813 - USG Ensemble™ Acoustical Drywall …
https://info.5y1.org/5-8-11-thread-specs_1_753620.html
1Compared to standard 5/8 in. Type X gypsum panels as presented in the Gypsum Association’s 5/8” Type X Environmental Product Declaration (FPI/GA/01/2014) with freshwater usage updated to be in accordance with ISO 14046. ... Fasten the perforated panels at 12” OC using 1-1/4” fine thread bugle head drywall screws. The fasteners must be ...
[DOC File]Model F1FR-300 CCP
https://info.5y1.org/5-8-11-thread-specs_1_f78090.html
Method of attaching the cover plate to the factory-assembled, steel sprinkler cup shall be a push-on and thread-off design allowing [½” (13 mm)] [5/16” (8 mm)] of adjustment. Rated working pressure shall be 300 psi (20.7 bar).
[DOC File]Process Specification for the Installation of Key-retained ...
https://info.5y1.org/5-8-11-thread-specs_1_dd5287.html
Threads in the parent material shall meet FED-STD-H28/2B, UN thread form, with a modified minor diameter, tolerance class 2B, except when noted as NS. Minimum full thread depth requirements shall be as noted in the Appendix A tables. 6.5 HOLE FINISH. The hole protective finish shall be completed as-specified on the engineering drawing. 6.6 ...
REVIEW OF NEW SPECIFICATION OR SPECIFICATION …
Jan 30, 2014 · Soil Retention Blanket (Straw-Coconut) shall be a machine produced mat consisting of 70 percent agricultural straw and 30 percent coconut fiber. It shall be either biodegradable or photodegradable. When specified lightweight polypropylene netting shall be 1.5 pounds per 1000 square feet; heavyweight netting shall be 2.9 pounds per 1000 square feet.