5 hp 120v electric motor
[DOC File]ac_motor_specs_july7.doc - Lutron Electronics Company Inc
https://info.5y1.org/5-hp-120v-electric-motor_1_4a079b.html
Each channel on the Group Controller shall be rated for 5 amperes, ¼ hp motor load at 120 VAC with a lifetime greater than or equal to 10,000 cycles. Each channel on the Group Controller shall be rated for 5 amperes, 1/2 hp motor load at 240 VAC with a lifetime greater than or equal to 10,000 cycles. The Group Controller shall be capable of providing power for up to three accessory controls ...
[DOC File]Side Downdraft-AEI Paint Booths
https://info.5y1.org/5-hp-120v-electric-motor_1_b6539c.html
Fixtures are supplied to accept either 120V or 277V power. Filtration: ... Electric Current: 208-230-460/60/3 3-wire. ETL Label. High Efficiency Motor. Burner/Blower Service Switches . Stainless Steel Burner /Aluminum Casting. Outdoor Safety Switch (Disconnect) and Motor Starters. Unit Location: Outdoor Installation. 7.5 HP Motor - ODP - High Efficiency EPACT. 1,320 BTUH (in 1000’s) 120( F ...
[DOC File]SECTION 233416 - CENTRIFUGAL HVAC FANS
https://info.5y1.org/5-hp-120v-electric-motor_1_d633ee.html
Provide variable and adjustable pitch sheaves for motors 15 hp and under, selected so required rpm is obtained with sheaves set at mid-position. Provide fixed sheave for 20 hp and over, with matched belts, and drive rated as recommended by manufacturer, or minimum 1.5 times (or as otherwise specified) nameplate rating of the motor. Provide multiple belts where motor is larger than 10 hp, such ...
[DOCX File]Section 10811exl.doc - Excel Dryer
https://info.5y1.org/5-hp-120v-electric-motor_1_29e7ad.html
Combination Motor and Blower: Series commutated, through-flow discharge, vacuum type; 5/8 HP, 24,000 RPM. Airflow rate: 20,000 linear feet per minute (101 meters per second) at air outlet, 17000 linear feet per minute (86) meters per second) at average hand position of 4 inches (102 mm) below air outlet. Includes a washable metal mesh filter for more reliable performance.
[DOC File]SECTION 102813.15 - WARM AIR HAND DRYERS
https://info.5y1.org/5-hp-120v-electric-motor_1_b2c117.html
Motor: Single Speed, 1/5 hp/140W 50/60 Hz 110 - 120V. Motor: Single Speed, 1/5 hp/140W 50/60 Hz 220 - 240V. Special Tools: Provide special tool for removing warm air dryers for internal access for servicing and adjusting. EXECUTION. INSTALLATION. Install warm air dryers in locations indicated, in accordance with manufacturer's written instructions, using recommended fasteners. Install units ...
[DOC File]Industrial & Commercial Services - PPL Electric
https://info.5y1.org/5-hp-120v-electric-motor_1_123dab.html
100 HP for primary (12.47 KV) services, or 750 HP for transmission (69 KV) services. This information is not currently available, but will be submitted by //. (Date required) Note: Please ensure all HP motor load is included in connected electrical load above. TABLE 1 Description of Equipment that the Largest Motor Drives. HP. Type of Motor Starter
[DOC File]The Snow Cone Machine
https://info.5y1.org/5-hp-120v-electric-motor_1_2a0ec5.html
The more blade that is exposed beyond the head will create a coarser ice chip. (see Figures 4 & 5) Figure 4 – Fine Setting Figure 5 – Coarse Setting Figure 6 – Motor shaft. Re-install the cutting head onto the motor shaft by sliding it in through the horn opening on the top of the machine.
CSI Specification - DL Dock Lift - Blue Giant
Power Unit: Remote 5HP (up to 12,000 lb. (5443 kg) capacity models) or 7-1-2 HP (15,000 to 20,000 lb. (6804 to 9072 kg) capacity models) power pack on 12 feet (3,657 mm) hydraulic hose. Includes all major components, motor, high-pressure gear pump, manifold, oil filters and oil reservoir. Power unit includes a pressure relief valve, load ...
[DOC File]Home | US Forest Service
https://info.5y1.org/5-hp-120v-electric-motor_1_05079f.html
See Table 2 for given HP, PF = KW. KVA. Voltage Dip. Determine maximum percentage voltage dip. This is basically what sizes the generator. If voltage dip is too large, the motor will over heat or not start because there is not enough torque to accelerate the motor. Motor torque falls off approximately as the product of reduced squared. For ...
[DOC File]COGSWELL - BidNet
https://info.5y1.org/5-hp-120v-electric-motor_1_49b290.html
Water Heater – 6 gallon; M/N: P6610 MSK; S/N: M02416172, 1650 watt, 120v. Room B-20( this was a weights a measures room) AC Unit – Data Aire, M/N: DAMA-0112-P; S/N: 2004-3661-A, 208v, 1 phase, R22; 1.5 hp, 12/2004 – 3 ton. BASEMENT C- WING . BOILER ROOM. BOILER ROOM. Boiler, Kewanee, #MTB-12087 670 MBH, 20 HP, 150 PSI, Cat/N H3S-20-G, Valve 80 lb/hr, 100sq ft, Order 845031. …
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.