60 amp 3 phase receptacle

    • [DOC File]PSG Section 26 28 16.13 - Eaton

      https://info.5y1.org/60-amp-3-phase-receptacle_1_b52be5.html

      2, 3, 4 and 6 poles (2, 3 and 4 poles on 800 A; 2 and 3 poles on 1200 A) Fusible and non-fusible. Mechanical lugs suitable for aluminum or copper conductors. Construction. Switch blades and jaws shall be visible and plated copper. Switches shall have a red handle that is easily pad-lockable with three 3/8-inch shank locks in the OFF position

      60 amp plug


    • [DOC File]GSA Advantage!

      https://info.5y1.org/60-amp-3-phase-receptacle_1_d08568.html

      Incoming is 1 each 60 Amp Hubbell Pin & Sleeve Inlet. Output is 9 each 20 Amp Hubbell or equal Spec Grade Duplex Receptacles (3 each Black, Red and Blue). CV-60-EXPO-1. Clear View Panels. 60 Amp Custom Built Clear View Panel that is UL Listed for Exposition Halls and Similar Locations; 3-Phase, 4-Pole, 5-Wire, 120/208Y.

      60 amp plugs and receptacles


    • [DOCX File]Architecture Engineering and Construction

      https://info.5y1.org/60-amp-3-phase-receptacle_1_2b228a.html

      Delete b if a generator-backed 208y/120 volt receptacle panel is available near by. Provide a 208Y/120 Volt, 60 amp minimum, 3 phase, main lugs only load center panel with circuit breakers to feed the battery charger, coolant jacket heater, motorized ventilation dampers, lights and receptacles. ...

      60 amp 3 phase plug


    • [DOC File]Functional Specification for 15 kV, 25 kV, or 35 kV ...

      https://info.5y1.org/60-amp-3-phase-receptacle_1_c14ff9.html

      Functional Specification for 15 kV, 25 kV, or 35 kV Underground Distribution Switchgear. Scope This specification applies to three-phase, [select #] - way [select # -source, select # -tap], 50-60 Hz, fully dead front, sectionalizing underground distribution switchgear; with maximum main bus rating of [select: 200 or 600] amperes continuous current and maximum tap rating of [select: 200 or 600 ...

      nema 60 amp receptacle


    • [DOC File]SECTION 323114 - AUTOMATIC GATE OPERATOR AND …

      https://info.5y1.org/60-amp-3-phase-receptacle_1_a0b1b2.html

      Edit appropriately for 3-phase services and if panelboard is required over din rail circuit breaker. PANEL. A 120/240 volt, service rated, single phase, 3 wire, 12 space, 60 amp 2P main, solid neutral in a NEMA 1 enclosure. Square D Q0412-24/Q0C12S, or equal. Provide with following 10,000 AIC circuit breakers: One Q0115, one Q0120, and one Q0315.

      60 amp 480 volt receptacle


Nearby & related entries: