600v 30a fused disconnect switch

    • PSG Section 16426A - Eaton

      The trip unit shall include a voltage transformer module, suitable for operation up to 600V, 50/60 Hz. The primary of the voltage transformer module shall be connected internally to the line side of the circuit breaker through a dielectric test disconnect plug.

      eaton 480v 30a fused disconnect


    • [DOC File]PSG Section 26 28 16.13 - Eaton

      https://info.5y1.org/600v-30a-fused-disconnect-switch_1_b52be5.html

      Switch operating mechanism shall be non-teasable, positive quick-make/quick-break type (except 30A plug-fuse type and compact design general-duty double-throw) Fusible switches shall be suitable for service entrance equipment and be equipped with factory installed neutrals, as …

      30 amp fused disconnect switch


    • [DOCX File]ARCAT, Inc.

      https://info.5y1.org/600v-30a-fused-disconnect-switch_1_8cfeaf.html

      Control sections include 6 or 12 in (152 or 305 mm) with disconnect, thermostat, pneumatic relay, transformer relay, relay, fused disconnect or duplex receptacle. ** NOTE TO SPECIFIER ** Delete thermostat not required. Thermostats: Single pole and disconnect switch. Thermostats: Double pole and disconnect switch. Controls: Built-in, tamperproof.

      30 amp 600v fusible disconnect


    • SECTION 16###-#

      Provide terminal blocks for customer connections, rated 600V 30A compression-box style that can accept up to #10 AWG. Internal terminal block connections shall be rated 600V 20A spring-cage style that can accept up to #12 AWG. Internal harness connections shall be rated 300V 10A spring-cage style.

      30 amp 480v fused disconnect


    • [DOCX File]SECTION 11 71 02, LABORATORY WASHING AND …

      https://info.5y1.org/600v-30a-fused-disconnect-switch_1_9cc0cd.html

      This control system shall provide automatic lead/lag sequencing with circuit breaker disconnects for each compressor with external operators, one non-fused main disconnect with external operators, full voltage motor magnetic starters with overload protection, redundant 120V control circuit transformers, visual and audible reserve unit alarm ...

      square d safety switch 600v


    • [DOC File]Buildings Maintenance Guide Cards - Internal Revenue Service

      https://info.5y1.org/600v-30a-fused-disconnect-switch_1_c59b58.html

      Inspect fused disconnect switches, wiring, conduit, and electrical controls for loose connections, charred or broken insulation, or other defects. Tighten, repair, or replace as required. Remove dust from air intakes, and check for corrosion.

      30 amp 600 volt disconnect


    • [DOC File]SECTION 11 71 00 - MEDICAL STERILIZING EQUIPMENT

      https://info.5y1.org/600v-30a-fused-disconnect-switch_1_896f80.html

      4. Fused Disconnect Switch: A NEMA 4X fuseable disconnect switch shall be provided and mounted alongside the electrical enclosure. J. Installation: 1. Coordinate with Mechanical for water supply and drains. 2. Coordinate with electrical for GFCI protection and receptacle compatibility. 2.15 COUNTER-TOP INSTRUMENT WASHER:

      30 amp fusible disconnect switch


Nearby & related entries: