7 step stringers pressure treated
[DOC File]Specification Listing - HUD Exchange
https://info.5y1.org/7-step-stringers-pressure-treated_1_63b82a.html
Install preservative treated, code approved, grab-able handrail supported by 4"x 4" treated posts, 4' on center. Rail to be free from cracks, splinters, and rough edges. Set first post in a 12"x 8"x 12" concrete sleeve, bolt remaining posts to stringer with 7" lags.
Wellesley, MA | Official Website
Trail Bridges and Steps Designs. Wellesley Trails Committee. 1. Bog Bridges. 1.1 Design. Bog bridges are used to cross muddy areas of trail. There are many different types of bog bridges designs, and this design using pressure treated wood has proven to be a good sustainable bridge for suburban woodland trails.It is simple to construct, very rigid, and has a long life span.
[DOC File]STANDARD SPECIFICATIONS FOR CONSTRUCTION OF TRAILS …
https://info.5y1.org/7-step-stringers-pressure-treated_1_36c4c4.html
Hew sill logs to provide a bearing surface for the log stringers and to provide the log stringers with a level top surface. Do not hew sill logs more than one-third their diameter. Do not level the top surfaces of the log stringers by shimming or notching their ends. 934.00.06 Log Stringers. Use logs greater than or equal to 10 feet in length.
STANDARDS
Install stairs using notched 2”x 12” standard grade pressure treated stringers set on a 3” thick concrete pad. Treads shall be solid, without perforations. The maximum riser height shall be 7 ¾”. The minimum tread depth shall be 10”. ... Work to include all new metal/lead flashing/step flashing, vent boots. Shingles to carry National ...
[DOC File]SECTION 900 – MATERIALS DETAILS
https://info.5y1.org/7-step-stringers-pressure-treated_1_4cab03.html
The radii of curvature shall be in increments of 3 m (10 ft) from a radius of 45.7 to 15.2 m (150 to 50 ft) inclusive and in increments of 1.5 m (5 ft) from a radius of 15.2 m (50 ft) to and including 6.1 m (20 ft). The steel channels specified on the plans shall be standard 127 mm (5 in.) channels weighing 10.0 kg/m (6.7 …
[DOC File]westchasewca.com
https://info.5y1.org/7-step-stringers-pressure-treated_1_488252.html
Must be made of cypress, pressure treated #2 spruce or pressure treated pine only. Posts to be four inch by four inch (4” x 4”) by ten feet (10’) and set in ground four feet (4’). Post spacing to be no more than eight feet (8’). Stringers to be two inches by four inches (2” x 4”) and attach to posts using 13d nails.
[DOC File]Home | Westchase Community Association | Tampa, FL
https://info.5y1.org/7-step-stringers-pressure-treated_1_76a1c4.html
Must be made of cypress, pressure treated #2 spruce or pressure treated pine only. Posts to be four inch by four inch (4” x 4”) by ten feet (10’) and set in ground four feet (4’). Post spacing to be no more than eight feet (8’). Stringers to be two inches by four inches (2” x 4”) and attach to posts using 13d nails.
[DOC File]TABLE OF CONTENTS
https://info.5y1.org/7-step-stringers-pressure-treated_1_bfb94a.html
7. Surfaced or Dressed Lumber. 8. Rough Lumber (b) Species and Grade (c) Inspection (d) Tolerances (e) Untreated Piling. 911.02 Treated Lumber (a) General (b) Bridge Lumber (c) Piling (d) Guardrail Posts, Braces, and Battens (e) Sign Posts (f) Sawed Timber Posts and Blocks for Thrie Beam and W Beam Guardrail. 1. Species and Grades. 2 ...
[DOCX File]Design Quality Standards - AHFA
https://info.5y1.org/7-step-stringers-pressure-treated_1_4160b9.html
11. Stairway components, such as stringers, treads, and risers must be constructed from steel or concrete. All project steps must include a kick plate in between each step beginning at the first step nearest to the ground and ending at the nearest step at the balcony or landing. Handrails and pickets must be constructed from steel or aluminum.
[DOCX File]virginia school bus specifications
https://info.5y1.org/7-step-stringers-pressure-treated_1_2c149a.html
The responsibility for compliance with the public school bus and public school MFSAB Specifications rests with dealers and manufacturers. If any dealer or manufacturer sells public school bus or public school MFSAB vehicles that do not conform to any or all of these Specifications, a general notice will be sent to all school divisions advising that equipment supplied by such dealer or ...
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.