75 kva transformer cut sheet

    • [DOC File]1 - Cooper Industries

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_d4f67f.html

      The transformer shall be cooled by the natural circulation of air over the tank surface, with an additional rating obtained by forced air circulated over the radiator or corrugate, shall be provided with KNAN/KNAF rated cooling including all control equipment, 15% for 750 kVA – 2000 kVA and 25% for 2500 kVA …

      75 kva dry type transformer


    • [DOC File]1 - Eaton

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_fa719f.html

      Additional capacity ratings shall be as follows; 15% for 750-2,000 kVA, 25% for 2,500-10,000 kVA, 33% for 12,000 kVA. OR The transformer shall be cooled by the natural circulation of air over the tank surface, with future kVA capacity built into the cooling surfaces and conductors.

      75 kva transformer wall bracket


    • [DOC File]Invitation to Bid #I65070

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_06c0f1.html

      TRANSFORMER, 167 KVA, Pole-Type, Distribution 25564GRD.Y/14760-138/277 Volt. Items 1 through 14: All per Seattle City Light Material Standards nine (9) page Spec. 0025.1, Revised 10/23/02, Attachment #2, including two (2) page Data Sheet, in receipt.

      75 kva 480 208 transformer


    • [DOC File]1 - Eaton

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_e3a345.html

      The transformer, filled with Envirotemp™ FR3™ fluid, shall have a 55/75°C average winding temperature rise rating. The above winding temperature rise shall not exceed 55°C when loaded at base kVA rating. The transformer shall provide an additional 22% continuous operating capacity at the 75°C rating. This transformer is identified as a ...

      112.5 kva transformer size


    • [DOCX File]Section 26 12 19, Pad-Mounted, Liquid-Filled, Medium ...

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_55c927.html

      SECTION 26 12 19. PAD-MOUNTED, LIQUID-FILLED, MEDIUM-VOLTAGE TRANSFORMERS. SPEC WRITER NOTE: Delete between //// if not applicable to project. This spec is applicable for transformers 2500 kVA and less, on 5 kV and 15 kV primary systems, with source not over 8.3 kV phase to ground.

      75 kva transformer dimensions


    • [DOC File]Seattle.gov Home

      https://info.5y1.org/75-kva-transformer-cut-sheet_1_51dab0.html

      TRANSFORMER, 75 KVA, Pole-Type, Distribution. 25564GRD.Y/14760-120/240 Volt. ... page Spec. 0025.1, Revised 2-03-97, Attachment #2, and two (2) page Data Sheet, Attachment #3, in receipt. On factory cut orders where the low voltage windings are paralleled for use for 208Y/120 volt operation:

      75 kva transformer weight