SECTION 260500 - COMMON WORK RESULTS FOR ELECTRICAL
Allen-Bradley Bulletin 513, or equal. Provide circuit breakers. Fuses are not acceptable. Provide overload relay. Overload relay shall be electronic, Allen-Bradley E3 Plus, or equal, or thermal overload, as noted on the drawings. Provide terminal strips for field terminations. Provide green run lights.
[DOCX File]Pendant Automation
https://info.5y1.org/allen-bradley-illuminated-e-stop_1_8b6db7.html
Allen-Bradley Compactlogix L3 Processor and I/O modules. ... “POWER ON” pilot light on CCP-100, CCP-200, CCP-300, and CCP-400 must be illuminated “EMERGENCY STOP devices RESET. System Air Pressure Present . ... If a rope switch or e-stop pushbutton is activated, the zone in which the device is located will shut down all conveyors in that ...
[DOCX File]SECTION 16481 - Wisconsin
https://info.5y1.org/allen-bradley-illuminated-e-stop_1_b7a618.html
One (1) input for a N.O. dry contact type input for a 2-wire remote start/stop One (1) input for a N.C. dry contact type input for external faults: (freezestats, fire alarm, smokes, etc). This input shall be factory wired to prevent both the VFD and bypass starter operation when external fault is present.
[DOC File]REQUEST FOR PROPOSAL
https://info.5y1.org/allen-bradley-illuminated-e-stop_1_2df061.html
The PLC shall be Allen-Bradley Model SLC 5/04 L541 or approved equal. A main processor unit, containing the CPU and control functions, shall be furnished for each of the programmable controllers. Each shall have the capability of addressing at least 4096 inputs and 4096 outputs or analog variables.
[DOCX File]SYSTEM OVERVIEW
https://info.5y1.org/allen-bradley-illuminated-e-stop_1_0e4137.html
Allen-Bradley Compactlogix L3 Processor and I/O modules. ... “POWER ON” pilot light on CCP-100, CCP-200, CCP-300, and CCP-400 must be illuminated “EMERGENCY STOP devices RESET. System Air Pressure Present . ... If a rope switch or e-stop pushbutton is activated, the zone in which the device is located will shut down all conveyors in that ...
[DOC File]TABLE OF CONTENTS
https://info.5y1.org/allen-bradley-illuminated-e-stop_1_506790.html
3. Provide a red light-emitting diode (LED) indicator lamp for run and a green LED for stop indication at FACP. D. Fire/smoke dampers shall close upon AC power failure. E. Supervision of fire alarm system components. If any of the following conditions occur, the fire …