3.Follow the recommendations of the National Roofing Contractors Association "Roofing and Waterproofing Manual" for design criteria. 4.Insure positive slope to drains occur; minimum of 1:50 (1/4inch per foot) without any "gutters" (no slopes between drains). Do not use on slopes over 1:12 (one inch per foot) except for flashings.
[DOCX File]ARCAT | Free Building Product CAD Details, BIM, Specs and …
https://info.5y1.org/arma-residential-asphalt-roofing-manual_1_937d65.html
** NOTE TO SPECIFIER ** Instructions on additional details for sealing Penetrations can be found in the ARMA's Residential Asphalt Roofing Manual and/or NRCA's Roofing and Waterproofing Manual Rake Edges: Install metal edge flashing over the Ice and Water protector membrane and roof deck underlayment; set tight to rake boards; lap joints at ...
[DOC File]SECTION 073113 - ASPHALT SHINGLES
https://info.5y1.org/arma-residential-asphalt-roofing-manual_1_e56e38.html
Install metal flashings according to recommendations in ARMA's "Residential Asphalt Roofing Manual" and asphalt shingle recommendations in NRCA's "The NRCA Roofing and Waterproofing Manual." Drip edge along gables shall be installed over the felt or ice/water shield while drip edge along the eaves is installed under the felt or ice/water shield.
[DOC File]A D D E N D U M # 3
https://info.5y1.org/arma-residential-asphalt-roofing-manual_1_81b2bf.html
Comply with recommendations in ARMA's "Residential Asphalt Roofing Manual" and with asphalt shingle recommendations in NRCA's "The NRCA Roofing and Waterproofing Manual." Apply self-adhering sheet underlayment at eaves and rakes from edges …
[DOC File]PART 1
https://info.5y1.org/arma-residential-asphalt-roofing-manual_1_610fc1.html
Underwriters Laboratories (UL) - Roofing Systems and Materials Guide (TGFU R1306) Sheet Metal and Air Conditioning Contractors National Association, Inc. (SMACNA) - Architectural Sheet Metal Manual. Asphalt Roofing Manufacturers Association (ARMA) National Roofing Contractors Association (NRCA) U.S. Green Building Council (USGBC)
[DOC File]CHAPTER 9
https://info.5y1.org/arma-residential-asphalt-roofing-manual_1_cc187e.html
(4) Roofing Underlayment Felts. o Roofing underlayment felts applied to a minimum. sloped roof of 4 in l2 shall be 15 pound asphalt. non-perforated saturated felt (or equal). o Low-sloped shingle roofs (2 in 12 to 4 in 12) require 2 layers of 15 pound non-perforated. saturated felt. o …