[DOCX File]DOCUMENTATION SUBMISSION PACKAGE - GBCI
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_b7526c.html
2. Revision Notes are in. green, italicized text. Parksmart projects registered after May 16, 2016 must seek certification under Parksmart Version 1.0 with Addenda. Projects registered on or prior to May 16, 2016 may seek certification under Parksmart Version 1.0 or …
[DOCX File]Foreword (Informative) - RESNET
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_33f7f6.html
Type: vented with net free vent aperture = 1ft2 per 150 ft2 of crawlspace floor area. ... Equation taken from Addendum s to ASHRAE Standard 62.2-2016. Where this . ... an Approved commercial hot water system calculator shall be used to determine the EF or UEF.
[DOC File]FORMULA SHEET - Homestead
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_56a8ce.html
Located the Pitot tube section providing 8-1/2 or more duct diameters upstream and 1-1/2 or more diameters down stream of Pitot tube free of elbows, size changes or obstructions. Provide an egg-crate type of flow straightener 5 duct diameters upstream of Pitot tube.
Home - ACCA
Briefly explain what is covered in ASHRAE 62.2 2016. ASHRAE 62.2 covers the methods for establishing the amount of outside air required in a residence based on size and occupant number. Why would a design that separates supply and return outlets by a greater distance be preferable?
[DOCX File]Foreword (Informative) - RESNET
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_e811f8.html
(Informative Note) Equation taken from ASHRAE Standard 62.2-2016, Normative Appendix C, equations (C7) and (C8). or calculations yielding equivalent results shall be used to determine the combined air exchange rate resulting from Infiltration in combination with …
[DOCX File][Document Title] - Victorian Energy Saver
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_78bc2d.html
Going from post-insulation regulations (Case 6) at 3.0 NatHERS stars to post 5-star (Case 7) (5.5 NatHERS stars) is a 2.5 NatHERS star difference but only a 0.7 (5.2 – 4.5) star difference in Scorecard. This is only about one-third of the change to Scorecard stars for each NatHERS star.
[DOCX File]New Jersey Clean Energy Collaborative
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_919685.html
Demand savings are estimated based on an estimated electric DHW demand of 2.13kW with 20% CF. Load shape and coincidence factors were developed by VEIC from ASHRAE Standard 90.2 Hot Water Draw Profile and NREL Red Book insulation data for Newark, NJ.
Schneider Electric CSI Specification Template
2” to 18” 2-Way and 2” to 16” 3-Way Linear Butterfly Valve Actuator with linkage NSR. The butterfly valve actuators are to be Non-Spring Return (NSR) two-position and proportional taking 0…10 Vdc or 4…20 mA models. All Actuators are to be NEMA 4, manual override (hand …
[DOCX File]i.
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_99cabf.html
Section 2.14, page 58, Table 2-22, of the 2012 TRM. Section 2.15 – Electric Water Heater Pipe Insulation, See. Section 2.15, page 62, of the 2012 TRM. Section 2.18 – Fuel Switching: Domestic Hot Water Electric to Gas, See. Section 2.18, page 74, Table 2-26, of the 2012 TRM. and Section 2.19 – Fuel Switching: Heat Pump Water Heater to Gas ...
[DOCX File]Note:
https://info.5y1.org/ashrae-62-2-2016-calculator-free_1_fda36e.html
System design, fundamentals and Goals of air-conditioning, Thermal loads – heating and cooling calculation using Energy Modelling software (e.g. eQuest, Design Builder), Indoor air quality issues Norms and standards- ASHRAE 62- VDI 6022, DIN 1946, ECBC 2017