Bad business settings controller

    • How do I know if my controller is bad?

      Verify with a voltmeter that there is 120 VAC +/- 10% (or 230 VAC if applicable) power at the controller. With a solenoid or voltmeter, check for 24 VAC power on the terminal strip. If there is power, from the transformer at the controller and no output, the transformer is defective and needs to be replaced.


    • How do I fix a faulty controller?

      The most common fix is to reset the controller. Press the reset button. If the controller display is still scrambled or locked, conduct a full reset. The controller will need to be reprogrammed. In rare cases, the front panel may be defective. Replace the front panel if resetting does not solve the problem.


    • What is a voltage setting on a B+ controller?

      9.3.1. Voltage Settings 2 Red continuously. Over Voltage: Allows the user to set the highest voltage that the controller will operate for. If the controller gets a higher reading than this setting on the B+ connection, it will switch into an error mode and flash 1 Green + 3 Red continuously.


    • Which position should a controller be oriented in?

      The controller can be oriented in any position, and meets the IP64/IP67 ratings for environmental protection against dust and water. However, the lo- cation should be carefully chosen to keep the controller as clean and dry as possible.


    • [PDF File]Alltrax TOOLKIT Instruction Manual XCT SR - SPM

      https://info.5y1.org/bad-business-settings-controller_1_ff6584.html

      Note: Upgrading the firmware does not change controller configuration. All user settings remain unchanged. Clicking “Yes” starts the automatic upgrade of the controller. The program will upgrade the software in the controller to the current version that is included with the Toolkit program. As it is upgrading the


    • [PDF File]7 Alarms 11 Error messages - Instrumart

      https://info.5y1.org/bad-business-settings-controller_1_1a664f.html

      1. Check controller label is the correct supply voltage for your application. 2. Connections ore shown on the socket label. 3.For connection to socket use. 250 Foston receptacles provided in accessory kit. 4.Recommended wire size for mains voltage and outputs 32/0.2 l .Omm2 (18 AWG 0.04·2) rated to 6 Amps/ 300Vot 702c. 5. For use with 2 wire ...


    • [PDF File]R-net DIAGNOSTIC GUIDE - PGDT

      https://info.5y1.org/bad-business-settings-controller_1_8f3565.html

      Bad Settings This occurs when the system detects incorrect or invalid programming data. Check the programmed settings of the system, particularly those in the Profiles and Configuration groups. If you cannot identify any settings that may be incorrect, save all the current settings in a file, then re-


    • [PDF File]TROUBLESHOOTING COMMON CONTROLLER PROBLEMS

      https://info.5y1.org/bad-business-settings-controller_1_1a2cb6.html

      Common Controller Problems • Blank Display • Scrambled or Locked Display • Display Shows “No AC” • No Station Output • Controller Does Not Recognize Module(s) • Sensor Does Not Shut Controller Off Visual Inspection Before taking steps to diagnose and troubleshoot problems, it is recommended to make a quick visual inspection of the


    • [PDF File]Manual Model 1268 - Curtis Instruments

      https://info.5y1.org/bad-business-settings-controller_1_59f300.html

      Three low current connectors are built into the 1268 controller. They are located in a row on the top of the controller: J1-1 Keyswitch Input (KSI) input and return for main contactor coil J1-2 Logic Enable input from run/store switch J1-3 Fuse Sense input from WalkAway™ fuse sense line J1-4 Logic Power power to controller logic J1-5 (not ...


    • [PDF File]DCX/NCX - Alltrax Inc

      https://info.5y1.org/bad-business-settings-controller_1_01a82b.html

      • Load test batteries, replace any bad batteries. • Check voltage between Controller B+ and B-. Voltage should be ±5V of the pack voltage. o If voltage is low, replace solenoid. If voltage ok, call Alltrax Technical Support • LED blinks 7 times red on controller power up. Overvoltage Alarm • Check voltage between Controller B+ and B-.