Bard power port card

    • [PDF File]PowerPort* Slim Implanted Port - BD

      https://info.5y1.org/bard-power-port-card_1_b06d8c.html

      (Identification Card, Key Card, etc.) Bard Access Systems surveyed Oncology Nurses to find out how they identify a port as power-injectable. Bard Access Systems surveyed Ct technologists to find out how they identify a port as power-injectable. 96% of responding Ct technolo-


    • [PDF File]CT GUIDE - BD

      https://info.5y1.org/bard-power-port-card_1_772559.html

      the PowerPort® Implantable Port for power injecting contrast media. •A PowerLoc® Safety Infusion Set Family† device may also be used to access a power-rated port for power injecting contrast media if indicated by the port manufacturer. • Contrast media should be warmed to body temperature prior to power injection.


    • [PDF File]POWER-INJECTABLE PORTS - AngioDynamics

      https://info.5y1.org/bard-power-port-card_1_adc3e0.html

      Smart Port power-injectable ports can be identified by the Smart. Angle* technology on the CT, CT Low-Profile, and Plastic CT models. The CT engraving on all models can be identified . through chest x-ray or CT Scout Scan. Each Smart Port patient receives an education packet—including an information booklet, ID card, key ring card and ID ...


    • [PDF File]Power Injectable Portal Systems - Kallus

      https://info.5y1.org/bard-power-port-card_1_f63e81.html

      port (BARD Access Systems CT Guide, 2007a). These items act as veriļ¬cation tools to health care providers that the patient has an implanted power in-jectable port. Also included in the port package are several medical record stickers with patient and device information for medical record documentation. Implementation


    • [PDF File]Patient Guide - C. R. Bard

      https://info.5y1.org/bard-power-port-card_1_238894.html

      Not every port is able to receive fluid at a high rate (power injection). You should inform your nurse that your port is a Bard® PowerPort® or PowerPort® Groshong® implantable port. You should also carry your port patient identification card with you. This card lets nurses know that you have a Bard®


    • [PDF File]Patient Guide - Premier Vein

      https://info.5y1.org/bard-power-port-card_1_90695b.html

      You should inform your nurse that your port is a Bard* PowerPort* device. You should also carry your port patient identification card with you. This card lets nurses know that you have a Bard* PowerPort* device. It also gives them important information they should know about the port. If you have questions about your port, please talk to your ...


    • [PDF File]Bard Access Systems, Inc. How to Care For Your

      https://info.5y1.org/bard-power-port-card_1_39996e.html

      Warning: Failure to ensure patency of the catheter prior to power injection studies may result in catheter failure. 4. Detach syringe. 5. Attach the power injection device to the PowerPICC SOLO* catheter per manufacturer’s recommendations. 6. Contrast media should be warmed to body temperature prior to power injection.


    • [PDF File]Instructions For Use - C. R. Bard

      https://info.5y1.org/bard-power-port-card_1_d3b55f.html

      • C. R. Bard, Inc. recommends the use of components provided in the kit. If additional items are to be used, check for proper fit prior to utilization. Note: Port body, catheter, and catheter-lock cannot be replaced with components outside the provided kit. • If vessel has been used for previous port placement evaluate for patency prior


    • [PDF File]United States Court of Appeals for the Federal Circuit

      https://info.5y1.org/bard-power-port-card_1_3e6c3f.html

      chart, a patient ID card, or a label provided on the product packaging. The ’478 patent claims methods for performing a power injection procedure that include identifying a vascular ac-cess port suitable for power injections and performing the power injection. Bard asserted claims 3, 5, 9, and 11 of the


    • [PDF File]1 2 3 4 5 6 - BD

      https://info.5y1.org/bard-power-port-card_1_0234ce.html

      • Bard Access Systems, Inc. recommends the use of components provided in the kit. If additional items are to be used, check for proper ... • Encourage patient to keep patient ID card and present it to clinicians accessing their port. ... , which in turn results in occlusion causing port system failure during power injection.


    • [PDF File]A guide to your Smart Port power-injectable port

      https://info.5y1.org/bard-power-port-card_1_6503d5.html

      We have also provided a Smart Port® power-injectable port identification card with a snap-off key ring card that we recommend you carry with you at all times. Present this card to any clinician who is going to access your port for any procedure, especially if that procedure is a power-injected Computed Tomography (CT) scan.


    • [PDF File]PRO: CVAD Accessing and Deaccessing Subcutaneous Ports

      https://info.5y1.org/bard-power-port-card_1_1387f3.html

      a. Power port product ID card in the form of a wallet card, bracelet or key fob b. Medical record documentation in the form of an operative note indicating the port type and brand. c. Palpable identifiers, applicable to Bard power port only. 4. Bard power ports require 2 identifiers in the form of: a.


    • [PDF File]MR Conditional Port - BD

      https://info.5y1.org/bard-power-port-card_1_05f692.html

      MR Conditional Port Bard Access Systems, Inc. 605 North 5600 West Salt Lake City, UT 84116 USA 801-522-5000 Clinical Information Hotline: 800-555-7422 Ordering Information: 800-545-0890 www.bardaccess.com www.portadvantage.com www.powerportadvantage.com * Bard is a trademark and/or registered


    • [PDF File]Implanted Port Education Program

      https://info.5y1.org/bard-power-port-card_1_d6568c.html

      03 what is a bard* port 03 about dual lumen ports 04 how is your port placed 04 how is your port used 05 how is your port accessed 05 care of your port 06 what is a powerport* device 06 cect scans / power injection 06 identification 07 important safety information 08 tell your clinician 08 common questions and answers


    • [PDF File]Nursing Management of Venous Access Devices: Implanted ...

      https://info.5y1.org/bard-power-port-card_1_cacbfa.html

      the Gripper,®® to access power to access power injectableinjectable ports if the port is not being used for power injection. If accessing with a PowerLoc ®® needle you MUST verify that the port is a power injectable port using minimum of two identifiers. Once patency is established and verification of power injectable port has


    • [PDF File]IV Access Policy CT - University of Florida

      https://info.5y1.org/bard-power-port-card_1_34d6e5.html

      Only power injectable central lines are an alternative option to IV access. A power injectable line will always be labeled with an approved rate for power injection. Make sure with Infusaports that an identification card or placement report states CT injectable. Some lines that are allowed: Bard Power Port with proper power injectable access line


    • [PDF File]7960-901 (2021 02) - Bard HVAC

      https://info.5y1.org/bard-power-port-card_1_d5cecc.html

      • 128 MB Micro SD card • Supplemental Instructions 7960-901. Instructions. 1. Disconnect power to the controller by unplugging the . 5-pin connector plugged into the back of the display (see Figure 1). Disconnect Ethernet cable connector too, if applicable. Be sure to use care when removing connectors to avoid damage to plug or display port. 2.


    • [PDF File]MC5300 and MC5600 Controllers - Bard HVAC

      https://info.5y1.org/bard-power-port-card_1_becda5.html

      Bard Manufacturing’s MC Series of controllers offer easy setup . and operation of WALL-MOUNT air conditioning, heat pump, and . dehumidification products. The MC5300 controller allows for control of up to 3 units and the MC5600 controller allows for control of up to 6 units. Special features including filter alarm, emergency ventilation,


    • [PDF File]3 Table of Contents - BD

      https://info.5y1.org/bard-power-port-card_1_2af7e6.html

      • Do not power inject through a port system that exhibits signs of clavicle-first rib compression or pinch-off as it may result in port system failure. • Intended for Single Patient Use. DO NOT REUSE. Bard Access Systems, Inc. products are single use devices and should never be reimplanted. Any device that has been contaminated by


    • [PDF File]Bard Access Systems, Inc.

      https://info.5y1.org/bard-power-port-card_1_987e16.html

      card, ID bracelet, or keychain they received when the port was implanted. • Always verify the patient has a PowerPort* port by at least two means and ensure they are accessed with a PowerLoc* Infusion Set, prior to power injection. • For additional guidance on recognizing a power injectable port / safety infusion set system,