Calculate void volume of column

    • [DOC File]ASSIGNMENT 5 – IX

      https://info.5y1.org/calculate-void-volume-of-column_1_7ab52f.html

      Calculate the required height of the columns allowing for sufficient backwash space. Solution. The section area A = Volume of GAC = 3m x 0.00785 = 0.02355 m3. The application rate or approach velocity . b) The residence time t = c) Assume the fractional void volumes for granular carbon columns is 0.5 (normally range from 0.40 to 0.55)

      calculate hplc column void volume


    • [DOC File]LABORATORY REPORT COVER PAGE - Penn Engineering

      https://info.5y1.org/calculate-void-volume-of-column_1_c8bcb0.html

      Dec 21, 2001 · The void volume of the column, Vo, was found by taking the product of the time of the peak absorption reading and the flow rate, which equaled 14.19 mL. This void volume was used as a basis of determining the V/ Vo value for ovalbumin. Table 1: Ovalbumin Elution Results

      how to calculate void volume


    • [DOC File]GPC - Louisiana State University

      https://info.5y1.org/calculate-void-volume-of-column_1_4f8082.html

      Void Volume ( Vo ): Also called interstitial volume or exclusion volume; It is the volume of solvent (mobile phase) that is located between the column packing particles. Pore Volume ( Vi ): Pore volume of all particles. Mobile Phase Volume (Vt ): Vt = Vo + Vi. Gel Volume ( Vg ): Volume occupied by the solid support (gel).

      column void volume calc


    • [DOC File]Gel Filtration Chromatography

      https://info.5y1.org/calculate-void-volume-of-column_1_fa0f5c.html

      From this line and the elution volume of an unknown protein, the molecular weight of the unknown can be estimated. Figure 3. Elution profile from filtration chromatography. Plot of elution volume against concentration for 4 proteins. V0 is the void volume of the column. Figure 4. Molecular weight vs. elution volume.

      void volume calculation


    • [DOC File]LABORATORY REPORT COVER PAGE

      https://info.5y1.org/calculate-void-volume-of-column_1_78ecc3.html

      The void volume for each column was calculated by taking the time at which the peak of the Blue Dextran curve occurred, converting it to minutes, and then multiplying by the flow rate. The void fraction could then be obtained from dividing the void volume by the total volume of the column (which was calculated by geometric measurements).

      hplc column void volume


    • [DOC File]Molecular Techniques and Methods

      https://info.5y1.org/calculate-void-volume-of-column_1_a07340.html

      Calculate the void volume by multiplying the volume collected in the individual fractions by die number of the fraction containing the maximal UV-absorbing protein. The void volume should be approximately 1/3 of the total bed volume.

      volume of voids formula


    • [DOC File]TEC~ICAL COMMITTEE ~EPRESENTATION

      https://info.5y1.org/calculate-void-volume-of-column_1_e13b56.html

      The total volume of air attributed to each class of voids is calculated by multiplying column 7 by column 8, which contains the volume of one void of the class diameter, to give the air content as a fraction and then multiplying by 100% to express this as a percentage. The result is placed in column 9.

      calculate void volume time hplc


    • [DOC File]justinust.files.wordpress.com

      https://info.5y1.org/calculate-void-volume-of-column_1_f41b81.html

      The volume of the free space of the packing is packing void fraction which is related to 1m3 of its volume. While the area related to 1m3 of the volume the packing is its specific surface area. ... To calculate for the pressure drop, the Ergun equation can be defined as: ... The liquid holdup is the fraction of liquid held up in packed column ...

      column void volume


    • [DOC File]Sizing of distillation columns - NTNU

      https://info.5y1.org/calculate-void-volume-of-column_1_77a28a.html

      Which is equivalent to a volume flow rate of 16,88 m3/s when using a molar density of 1,09 kgmol/m3. A maximum allowable flow rate in the reactor lead to a cross section area of 6,75 m2 ,when assuming a catalyst void fraction of 0,5. This will lead to a total number of 5373 tubes inside the reactor shell.

      calculate hplc column void volume


Nearby & related entries:

To fulfill the demand for quickly locating and searching documents.

It is intelligent file search solution for home and business.

Literature Lottery

Advertisement