      sprinkler system in accordance with section 903.3.1.1 or 903.3.1.2 shall not be greater than one-half of the floor area of the room, provided: 3.1. Except for enclosed closets and bathrooms, the mezzan ine shall be open to the room in which such mezzanine is located. 3.2. The opening to the room shall be unobstructed except for walls not


    • [PDF File]ICC CODE CORNER 2012 IFC Code & Commentary - Campus Fire Safety

      https://info.5y1.org/cbc-table-1004-1_1_d8f9fd.html

      Table 1004.1.2. For areas without fixed seating, the occupant load shall not be less than that number determined by dividing the floor area under consideration by the occupant load factor assigned to the function of the space as set forth in Table 1004.1.2. Where an intended function is not listed in Table 1004.1.2, the fire code official shall


    • Metal Five County of Napa B - Napa County, California

      CBC Table 2304 10.1. Fasteners in Treated Wood. Staples in preserva-tive-treated wood and fire-retardant-treated wood are now required to be made of stainless ... CBC Table 1004.5 and 1004.8 Transfer Type Shower Compartments. New criteria for the allowance of transfer-type shower compartments. The California State Architect is


    • IR A-26.cc: Occupancy Classifications and Occupant Load ... - California

      Shall use an occupant load factor of 15 (net) per CBC, Table 1004.1.2. 2.5 Locker rooms: Shall be classified as Group “B” occupancy with an occupant load factor of 50 (gross). ... calculated using CBC section 1004.1.2, applying an occupant load factor of 15 (net). Where fixed seating is provided, the occupant load shall be determined per ...


    • INITIAL STATEMENT OF REASONS FOR PROPOSED BUILDING STANDARDS OF THE ...

      is being proposed to become Table 4-1. 2. Column name. The column name “occupancy” is changed to “function of space”. This matches the format of CBC Table 1004.5, and is more indicative of the column’s purpose—that of the actual use of a space, not the fire/life safety aspect that is the focus of Table 1004.5.


    • 1004.1.1 - Occupancy Loading

      Section: Table 1004.1.1 Rev. 1: September 12, 2014 General Information: The following table is a list of frequently asked questions about uses. The occupant load information provided in this list is intended as a guide only. The actual calculated load used in a design should be verified with and approved by the local inspection department. 1.


    • [PDF File]Maximum Floor Area Allowances TECHNICAL BULLETIN Per Occupant BLDG 10 1

      https://info.5y1.org/cbc-table-1004-1_1_950517.html

      not listed in the California Building Code (CBC) Table 1004.1.2. The following floor area allowances per occupant shall be used when determining the number of occupants in a space. ... 1. Arcades 11 gross 2. Auto Repair Garage 200 gross 3. Bar counter (3ft wide for full length of the counter) 5 net 4. Billiard Parlors 30 net


    • [PDF File]Table 1004.1.2 Maximum floor area allowances per occupant

      https://info.5y1.org/cbc-table-1004-1_1_be4578.html

      Table 1004.1.2 has a finite number of entries, and for educational occupancies, the available choices are limited to 20 net square feet per occupant for classrooms, and 50 net square feet for shops and vocational rooms. Laboratories are not mentioned by name in Table 1004.1.2, however Section 1004.1.2 states "where an intended


    • TENANT IMPROVEMENT PLAN REVIEW COMMENTS - Dana Point, California

      Occupant Loads: Calculate the maximum occupant load per CBC Table 1004.1.2 for each dining room and for waiting areas and for patio dining area in a restaurant and list it on the floor plan. FIRE RESISTIVE CONSTRUCTION . B000-NAME Page 4 of 12 24. Clarify all occupancy separation walls within the unit and with the adjacent tenants (where required).


    • [PDF File]2016 California Codes - Integrated Engineering Services

      https://info.5y1.org/cbc-table-1004-1_1_e33ff5.html

      Also required by CFC 1004.1.2. CBC Chapter 10 1006 & 1007 Number of Exits and Exit Access Doorways Means of egress requirements have been consolidated. Table 1006.2.1 (formerly tables 1014.3 & 1015.1 Also required by CFC 1006 & 1007. CBC Chapter 10 1009.8 Two‐Way Communication Systems ...


    • [PDF File]2018 CSBC / 2018 CSFSC Part III. Chapter #10. Means of Egress. Table of ...

      https://info.5y1.org/cbc-table-1004-1_1_0bc47a.html

      1004.1.1 Cumulative Occupant Loads. Intervening Spaces. Adjacent Levels. 1004.1.2 Areas without fixed seating. Table 1004.1.2. Ct. Amd. Removed Exception 1004.2 Increased Occupant Load. 1004.3 Posting of Occupant Load. Assembly Occupancy. 1004.4 Fixed Seating. 1004.5 Outdoor Areas. 1004.6 Multiple Occupancies. Section 1005. Means of Egress ...


    • IR 31-1: Construction and Installation of Free-Standing ... - California

      Where combination table/bench type seating is provided, the calculation shall be based on one person for each 18 inches of linear bench (seat) length. (CBC 1004.6). 9.2 Structures covering areas used for instructional purposes such as outdoor classrooms shall be calculated at 20 sq. ft. per person. (CBC Table 1004.5).


    • Access to Exits and Exit Separation Distance

      consideration as described in CBC Table 1004.1.2, Table 1 below, provides the required number of square feet required for each occupant in the building or space (extracted from Table 1004.1.2) for typical uses within the City of Carmel-by-the-Sea. Table 1. Maximum Floor Area Allowances Per Occupant Function of space Occupant load factor. a


    • (Effective July 1, 2023) WAC 51-54A-1004 Occupant load.

      1004.5.1 Increased occupant load. The occupant load permitted in any building, or portion thereof, is permitted to be increased from that number established for the occupancies in Table 1004.5, provided that all other requirements of the code are met based on such modified num-ber and the occupant load does not exceed one occupant per 7 square


    • [PDF File]table 1004.1.2 - ICC

      https://info.5y1.org/cbc-table-1004-1_1_27fa5a.html

      For SI: 1 square foot 5 0.0929 m2. a. Floor area in square feet per occupant. (Remaining portions of table not shown are unchanged.) ChaNGE sIGNIFICaNCE: For years the code has provided two occu-pant load factors for retail spaces, with a smaller occupant load factor be-ing used for grade floors and basements and a larger occupant load factor


    • [PDF File]135 - 2017 BCM 2902 A1 - Minimum Number of Required Plumbing Fixtures

      https://info.5y1.org/cbc-table-1004-1_1_bb41f9.html

      100 gross based on Table 1004.1.2 of the BC. 4. In occupancies serving ten or fewer people, one toilet facility, designed for use ... 2016 CBC/ 2017 LACBC 03-01-017 Page 1 of 2 ALL-GENDER TOILET FACILITY IDENTIFICATION BACKGROUND Assembly Bill 1732 (Ting, Chapter 818, Statutes of 2016) was signed into law on ...


    • FUNCTION OF SPACE FACTOR LOAD OCCUPANT - Washington

      Table 1004.5, Maximum Floor Area Allowances Per Occupant Table 1004.5 Maximum Floor Area Allowance Per Occupant FUNCTION OF SPACE OCCUPANT LOAD ... Certified on 7/14/2022 WAC 51-50-1004 Page 1. FUNCTION OF SPACE OCCUPANT LOAD FACTORa Kitchens, commercial 200 gross Library Reading rooms 50 net Stack area 100 gross


    • [PDF File]Technical BUlleTin Floor area allowances BlDG-10-1 - San Diego

      https://info.5y1.org/cbc-table-1004-1_1_ff1a10.html

      BlDG-10-1 January 2014 Floor area allowances CITY OF SAN DIEGO DEvElOpmENT SErvICES 1222 FIrST AvENUE, mS-401 SAN DIEGO, CA 92101-4101 ... (CBC) Table 1004.1.2. The following floor area allowances per occupant shall be used when determining the number of occupants in a space. OCCUPANT LOAD FACTOR a 1. Dance


    • [PDF File]2019 California Building Code (CBC) Changes

      https://info.5y1.org/cbc-table-1004-1_1_735ec9.html

      replicated in the CBC. 503.1 and 706.1 Building Height and Area Limitations. The use of a fire wall is now strictly limited to the determination of permissible types of construction and allowable area. 503.1.4 Occupied Roofs. A roof level may be an occupied roof provided the occupancy of the roof is an occupancy that is


    • [PDF File]NUMBER OF PLUMBING FIXTURES PLMB 4 1 - San Diego

      https://info.5y1.org/cbc-table-1004-1_1_3eaddd.html

      The minimum number of plumbing fixtures shall be provided in per CPC Table 422.1, except those structures governed by the Office of Statewide Health Planning and Development (OSHPD) shall comply with CPC Table 4-2. ... uses listed in CBC, Table 1004.1.2 multiplied by 2. B. Occupant Load Breakdown. The occupant load used for determining the minimum