Condenser coil replacement

    • [DOCX File]SECTION 23 81 43 - AIR-SOURCE UNITARY HEAT PUMPS

      https://info.5y1.org/condenser-coil-replacement_1_830ae1.html

      G.Evaporator and Condenser Coils: Internally finned, DN 10 (NPS 3/8) copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. The evaporated coil and condenser coil shall be leak tested at the factory to 1378 kPa (200 psig) and pressure tested to 2756 kPa (400 psig).

      condenser coil replacement cost


    • [DOC File]VOYG.DOC - MORGANIZER

      https://info.5y1.org/condenser-coil-replacement_1_9a5188.html

      The DX coil must be intertwined; horizontal split coils are not acceptable. The vendor will be responsible for changing the coil out in the field if a horizontal coil is substituted with or without approved submittals. 2.08 CONDENSER SECTION. A. Provide all aluminum microchannel type coil…

      trane condenser coil


    • [DOC File]PART 1

      https://info.5y1.org/condenser-coil-replacement_1_46f5fe.html

      EVAPORATOR COIL & HOT GAS REHEAT COIL. Evaporator coil with minimum 3/8 inch copper tubes mechanically expanded onto aluminum fins. Provide coils indicated for DX cooling. Ensure face velocity does not exceed 500 FPM. The unit shall contain a hot gas reheat coil with a modulating reheat control valve and an electronic controller.

      lennox ac condenser coil replacement


    • [DOCX File]Data Aire Series DX Units Guide Specifcations

      https://info.5y1.org/condenser-coil-replacement_1_4edc83.html

      The condenser coil shall be constructed of copper tubes and corrugated aluminum fins. The condenser coil shall be equally circuited for each refrigeration compressor. A receiver shall be factory mounted with head pressure control and solenoid valve for each circuit.

      trane condenser coil replacement


    • [DOCX File]Other

      https://info.5y1.org/condenser-coil-replacement_1_3de62a.html

      When fitting a new condenser coil to a ThinLINE unit, this bolt should not be installed. New condenser coils being supplied as replacement by Carrier may not have the bolt hole; therefore no action needs to be taken. This modification covers replacement part numbers 81-01575-00SV and 69NT43-202-20.

      ac condenser coil replacement


    • [DOC File]TPS SEC Bid - Connecticut

      https://info.5y1.org/condenser-coil-replacement_1_c3d716.html

      REPLACEMENT OF CONDENSER UNIT AND COILS . AT TOWN OF TRUMBULL LIBRARY. BID 6369 DUE: MARCH 4, 2020 @ 2:00PM. PROPOSAL FORM continued . Total cost for REPLACEMENT OF CONDENSER UNIT AND COIL ON TRUMBULL TOWN LIBRARY. Per specifications and scope of work. TOTAL proposed (turnkey) FIGURES $_____

      replacement hvac coils


    • [DOC File]Light Rail Vehicle Request for Proposals (RFP) Procurement ...

      https://info.5y1.org/condenser-coil-replacement_1_71ac8e.html

      TS 7.4.3 Condenser Fan 170. TS 7.4.4 Refrigerant Charge 170. TS 7.4.5 Qualification and Climate Room Testing 170. TS 7.4.6 Design Approval 171. TS 7.5 Interface Requirements 172. TS 7.5.1 Power Supply 172. TS 7.5.2 Condenser Fan 172. TS 7.5.3 Unit Mounting 172. TS 7.5.4 Controls 172. TS 7.5.5 Portable Test Equipment 172. TS 7.6 Maintenance ...

      carrier condenser coils replacement


    • [DOCX File]Home Page - Beverage-Air

      https://info.5y1.org/condenser-coil-replacement_1_9c29f0.html

      Warranty Guidelines. Maximum Standard Labor Allowance for Repair of Equipment . One-Half Hour of Labor for diagnosis of unit problem. One-Hour Labor for Replacement of (and test of unit) :

      evaporator coil and condenser replacement


    • [DOC File]SECTION 237400 - PACKAGED OUTDOOR HVAC EQUIPMENT

      https://info.5y1.org/condenser-coil-replacement_1_8f345b.html

      Refrigerant Coils: [Evaporator and condenser] [Evaporator, condenser, and reheat condenser] coils shall be designed, tested, fabricated, and rated according to ARI 410 and ASHRAE 33. Coils shall be leak tested under water with air at 315 psig (2170 kPa). EVAPORATOR COIL

      condenser coil replacement cost


    • [DOC File]PART 1

      https://info.5y1.org/condenser-coil-replacement_1_2b6e4a.html

      The condenser reheat coil shall be positioned to have a space upstream of the evaporator to prevent moisture carryover and re-evaporation. Provide drain pan and downspouts for cooling coil banks of more than one coil high. Ensure face velocity does not exceed 500 FPM. Coil to contain a minimum of six rows and a maximum of 8 to 12 Fins per Inch ...

      trane condenser coil