Copper pipe fittings chart
“CC” Threads - Mueller Co.
Cast Iron Pipe First large diameter pipe, used since late 1600s. Cement Lining Lining sprayed on the inside of the pipe common in cast and ductile iron pipe. CTS Copper Tube Size (3/4” inside diameter, 7/8” outside diameter). Material with same OD as nominal size copper tubing. DIPRA Ductile Iron Pipe Research Association.
[DOC File]130G-1
https://info.5y1.org/copper-pipe-fittings-chart_1_9f2778.html
This is the thinnest-walled form of copper pipe. b. Additional Information Regarding Rigid Copper Pipe. 1) Rigid copper pipe diameter is measured by the nominal ID. 2) The OD is a given nominal size which remains the same for all four weights of pipe. 3) Rigid copper pipe is …
[DOC File]Copper Guide Specifications
https://info.5y1.org/copper-pipe-fittings-chart_1_42acc5.html
6. ASME B16.24 Cast Copper Alloy Pipe Flanges and Flanged Fittings, Class 150, 300, 400, 600, 900, 1500, and 2500. 7. ASME B16.26 Cast Copper Alloy fittings for Flared Copper Tubes. 8. ASME B16.29 Wrought Copper and Wrought Copper Alloy Solder-Joint . Drainage Fittings - DWV. 9. ASME B16.50 Wrought Copper and Copper Alloy Braze-Joint Pressure ...
[DOCX File]Section 23 23 00 Refrigeration Piping - Veterans Affairs
https://info.5y1.org/copper-pipe-fittings-chart_1_739e3a.html
a.Use Type BcuP, copper-phosphorus alloy for joining copper socket fittings with copper tubing. b.Use Type BAg, cadmium-free silver alloy for joining copper with bronze or steel. c.Swab fittings and valves with manufacturer's recommended cleaning fluid to remove oil and other compounds prior to installation.
[DOC File]Here are tips and suggestions on how to work with copper pipe
https://info.5y1.org/copper-pipe-fittings-chart_1_042b41.html
The fittings illustrated are by no means the complete array of copper pipe fittings. Other fittings are available to help solve special piping problems. STEP 3 FIG. 3 - Use a hacksaw or tube cutter to cut copper pipe. CUTTING COPPER PIPE . You can cut copper pipe with a regular hacksaw or a copper tube cutter (Fig. 3). Although both will make a ...
[DOCX File]0751p AQUATHERM in mechanical piping - NATSPEC
https://info.5y1.org/copper-pipe-fittings-chart_1_1758ea.html
Class: Insert class appropriate to the pipe material and application or omit if standard text is adequate e.g. standard text for copper pipe is AS 1432 Type B so it does not need to be repeated here. For AQUATHERM pipe insert the SDR code. The lower the SDR, the thicker the pipe …
[DOC File]SECTION 221113 - FACILITY WATER DISTRIBUTION PIPING
https://info.5y1.org/copper-pipe-fittings-chart_1_597405.html
Fittings: ANSI B16.22, wrought copper. Minimize joints. Joints shall be flare connection or brazed. All fittings shall be lead free. HDPE PIPE AND FITTINGS. HDPE Pipe, AASHTO/ASTM M294/F892, AWWA C906 meeting ANSI/NSF Standard 14, SDR 7.0 corrugated with integrally formed smooth interior. N-12 pipe by Advanced Drainage Systems, Inc. (ADS).
[DOC File]NATIONAL MOTOR FREIGHT CLASSIFICATIONS
https://info.5y1.org/copper-pipe-fittings-chart_1_a0a358.html
Brass, Bronze, and Copper (not alloyed) Bar 30220 60. Scrap 30760 55. Sheet 30740 Sub.2 60. Wire 30920 Sub.1 60. Other Forms 136500 Sub.1 70. Lead (not alloyed) Bar 110140 55. Scrap 110410 55. Sheet 110430 60. Slab 110370 55. Wire 110520 60. Other Forms 136500 Sub.1 70. Lead Alloys Bar, Slab 135850 Sub.1 55 Other Forms 135850 Sub.2 60
[DOCX File]Mechanical Academy - Mechanical Team
https://info.5y1.org/copper-pipe-fittings-chart_1_79f874.html
4. Estimate pipe diameter from pipe sizing tables in CIBSE Guide C. 5. Measure the pipe run from drawings. 6. Calculate length of pipe equal to resistance of fittings. The Total equivalent length of a fitting = Equivalent Length x Pressure Loss factor (Zeta). 7. Calculate effective pipe length. 8.
[DOCX File]Section 22 61 13.74 - DENTAL COMPRESSED-AIR PIPING
https://info.5y1.org/copper-pipe-fittings-chart_1_9a0db8.html
Wrought copper fittings shall be solder joint complying with ASME B16.22, dimensions for brazed joints complying with ASME B16.50. Brazing filler Metals shall be BCuP series, copper-phosphorus with a melting temperature greater than 538 deg C (1000 deg F) allows for general duty brazing conforming to AWS A5.8M/A5.8.Flux shall be strictly ...