Cordis smart iliac stent


    • [PDF File] SMART RADIANZ Product Sheet 10-27-22 - Cordis

      http://5y1.org/file/27451/smart-radianz-product-sheet-10-27-22-cordis.pdf

      The first and only iliac indicated stent that is purposely designed for above-the-knee peripheral arterial disease ... for indications, contraindications, side effects, suggested procedure, warnings and precautions. CORDIS, Cordis LOGO, BRITE TIP RADIANZ, SABERX RADIANZ, S.M.A.R.T. RADIANZ, and ... SMART RADIANZ Product Sheet 10-27-22

      TAG: iliac stent icd 10


    • [PDF File] Cordis S.M.A.R.T.

      http://5y1.org/file/27451/cordis-s-m-a-r-t.pdf

      Cordis S.M.A.R.T.® Vascular Stent Systems ... Vascular Stent Systems Reference: 1. Matsumi , Tobita , Shishido , et al. Long-term outcomes of SMART stent implantation in patients with femoro-popliteal disease. Catheter Cardiovasc Interv. 2016 Nov 88(5): 832-841. doi: ... C06020SL C06020ML Iliac SFA 6 20 4-5 C06030SL C06030ML Iliac SFA 6 30 4-5

      TAG: cordis stent implant card


    • [PDF File] S.M.A.R.T.™ Family of Stents Brochure - Cardinal Health

      http://5y1.org/file/27451/s-m-a-r-t-family-of-stents-brochure-cardinal-health.pdf

      The Cordis S.M.A.R.T.™ Stent family of Nitinol Stents The S.M.A.R.T.™ Stent System has a legacy of confidence with: • More than 1 million Cordis S.M.A.R.T.™ Stents sold • Outstanding clinical evidence ... J-SMART Registry». 2011. Circulation Journal. doi: 10.1253/circj.CJ-10-1029. 3. Bunte et. al, Long-term clinical and quality of ...

      TAG: cordis velocity stent mri safety


    • [PDF File] The Nitinol SMART Stent vs Wallstent for Suboptimal Iliac …

      http://5y1.org/file/27451/the-nitinol-smart-stent-vs-wallstent-for-suboptimal-iliac.pdf

      PURPOSE: The Cordis Randomized Iliac Stent Project–US (CRISP-US) trial evaluated, with an equivalence design, the performance of the shape memory alloy recoverable technology (SMART) nitinol self-expanding stent and the stainless steel Wallstent for treating iliac artery disease after suboptimal percutaneous transluminal angioplasty (PTA).

      TAG: cordis smart flex biliary stent


    • [PDF File] Patient Device Information

      http://5y1.org/file/27451/patient-device-information.pdf

      COPY-CORDIS-23024 Rev.1 PRECISE PRO RX® Nitinol Stent System What PRECISE PRO RX® Nitinol Stent System is Used For The PRECISE PRO RXNitinol Stent is indicated for use in patients with atherosclerotic disease and non-atherosclerotic lesions of the carotid artery(ies) Product Description The PRECISE PRO RX® Nitinol Stent is a self-expanding

      TAG: cordis coronary stent mri safety


    • [PDF File] SUMMARY OF SAFETY AND EFFECTIVENESS DATA (SSED)

      http://5y1.org/file/27451/summary-of-safety-and-effectiveness-data-ssed.pdf

      in the biliary tree and iliac arteries. These products are also being marketed for vascular ... April 9, 2012, Cordis initiated a limited recall on32 lots of SMART® Cordis Nitinol Stent Transhepatic Biliary System and SMART® CONTROL® Nitinol Stent Transhepatic . PMA 1'120002: FDA Summary of Safety and Effectiveness Data page 5 ...

      TAG: cordis renal stent mri safety


    • [PDF File] S.M.A.R.T. Flex Vascular Stent System - Cardinal Health

      http://5y1.org/file/27451/s-m-a-r-t-flex-vascular-stent-system-cardinal-health.pdf

      S.M.A.R.T.™ Flex Vascular Stent System Product Description Stent Diameters: 9-10 mm Stent Delivery System Working Lengths: 80 cm (S suffix) and 120 cm (M suffix) Indications: common and external iliac arteries Type: Fully connected yet flexible stent design Material: Nitinol, with tantalum markers on stent ends Maximum Guidewire: 0.035"

      TAG: cordis carotid stent mri safety


    • [PDF File] Cordis S.M.A.R.T. CONTROL Nitinol System

      http://5y1.org/file/27451/cordis-s-m-a-r-t-control-nitinol-system.pdf

      Cordis S.M.A.R.T.® Stent System for Iliac Arteries 10 Be sure to ask your doctor to explain the risks and benefits of your treatment options and answer any questions you or your family may have. Cordis S.M.A.R.T.® Stent System. P Patients with one or more of the following characteristics might

      TAG: cordis stent mri safe


    • [PDF File] Quick Compendium: The S.M.A.R.T. Stent - Cordis

      http://5y1.org/file/27451/quick-compendium-the-s-m-a-r-t-stent-cordis.pdf

      STROLL study (SMART Niti-nol Self-Expanding Stent in the Treatment of Obstructive Super-ficial Femoral Artery Disease).1 The STROLL study was de-signed as a pivotal trial to provide clinical data to support expanding the indication of the SMART stent to include treatment of le-sions in the superficial femoral artery (SFA). The trial design and

      TAG: cordis iliac stent mri safety


    • [PDF File] Cordis S.M.A.R.T.C ONTROL

      http://5y1.org/file/27451/cordis-s-m-a-r-t-c-ontrol.pdf

      Launched in 1998, the Cordis S.M.A.R.T.™ Nitinol Stent System continues to go from strength to strength. The classic ... 2007: Long SMART ™ Nitinol Stent System 120mm and 150mm (6mm-8mm diameters) Controlled Deployment 6F delivery profile (7F: 12-14mm Ø) Innovative coil construction inside

      TAG: cypher cordis stent mri safety


    • [PDF File] VENOUS STENTING 2024 CODING AND REIMBURSEMENT …

      http://5y1.org/file/27451/venous-stenting-2024-coding-and-reimbursement.pdf

      Transcatheter placement of an intravascular stent(s), open or percutaneous, including radiological supervision and interpretation and including angioplasty within the same vessel, when performed; initial vein J8 Y699 $6, 37239 Transcatheter placement of an intravascular stent(s), open or percutaneous,

      TAG: cordis stent mri compatibility


    • [PDF File] Cordis S.M.A.R.T. Control Nitinol Stent System for the Iliac …

      http://5y1.org/file/27451/cordis-s-m-a-r-t-control-nitinol-stent-system-for-the-iliac.pdf

      THE CORDIS S.M.A.R.T.TM STENT SYSTEM FOR ILIAC ARTERIES The Cordis S.M.A.R.T.TM Stent System for iliac arteries is made of a metal alloy called nitinol (nickel titanium). The stent is contained in a delivery system for passage into the body to the iliac arteries. The Cordis S.M.A.R.T.TM Stent System should only be used by physicians who are

      TAG: cordis smart stent mri safe


    • [PDF File] Cordis S.M.A.R.T. Control - viSole

      http://5y1.org/file/27451/cordis-s-m-a-r-t-control-visole.pdf

      S.M.A.R.T.TM Nitinol self-expanding stent system quickly proved a winner with endovascular interventionists worldwide. S.M.A.R.T.eR, the second generation, saw the introduction of MicroMarker Cordis S.M.A.R.T.™ Control Nitinol Stent System Controlled Deployment S.M.A.R.T.TM Control ... Long SMART™ 120mm and 150mm (6mm-8mm …

      TAG: cordis cypher stent mri


    • [PDF File] For the Treatment of Superficial Femoral Artery (SFA) or Iliac …

      http://5y1.org/file/27451/for-the-treatment-of-superficial-femoral-artery-sfa-or-iliac.pdf

      Up to 300% greater stability for accurate placement with the S.M.A.R.T.™ Vascular Stent Systems. A foundation built on uniform scaffolding and small cell size. STENT | STABILITY 1. Cordis 2013 Data on file Cordis S.M.A.R.T. Vascular Stent 36 Struts/6 Bridges Medtronic Protégé EverFlexTM Stent 32 Struts/4 Bridges Bard LifeStent™ Stent

      TAG: cordis smart control mri safety


    • [PDF File] Radiology Recent News | Department of Radiology

      http://5y1.org/file/27451/radiology-recent-news-department-of-radiology.pdf

      %PDF-1.3 %Äåòåë§ó ÐÄÆ 4 0 obj /Length 5 0 R /Filter /FlateDecode >> stream x ½Ûr£Éqï{ §@ì+ŽCMá|ðÝH iÍ Úê–íX _ A4 ‰ (€œQ¯÷qÄŽõ8Û±Þgÿþÿ̪¯‚lÉ1 ÓÈ:feå¹ê+þ¥ÿÏý¿ô ü7 , ýÙpÔ?lúÿÚßõ þëã° {Ô¿#ýû‹ ýwƒëÁ`0é \÷gî3ëOg×Ëa 4 ]O–½ ýŸ \ ¯ ¬ÿñsÿßûWÓþ7ü¾ú·øg´ü¦ÿn8 Ž&ý«ÑB¿ÇÃɨ 5 .ßM ãÁ ...

      TAG: cordis smart control stent


    • [PDF File] Summary of Safety and Effectiveness Data (SSED)

      http://5y1.org/file/27451/summary-of-safety-and-effectiveness-data-ssed.pdf

      The original Protégé™ GPS Carotid Stent System PMA (P060001) was approved on January 24, 2007 and is indicated for the treatment of patients at high risk for adverse events from ... Cordis SMART Stent (Iliac, SFA) 9mm: RRF - 15.24; COF - 5.05 10mm: RRF - 14.31; COF – 3.90 12mm: RRF - 9.20; COF - 3.96 IDEV Supera (SFA, proximal

      TAG: cordis biliary stent mri safety


    • [PDF File] Cordis Smart Control Vascular Stent System - Patient Implant …

      http://5y1.org/file/27451/cordis-smart-control-vascular-stent-system-patient-implant.pdf

      COPY-CORDIS-23025 Rev.1 Cordis S.M.A.R.T. CONTROL® Vascular Stent System What Cordis S.M.A.R.T. CONTROL® Vascular Stent System is Used For The Cordis S.M.A.R.T. CONTROL® Vascular Stent System is for use in patients with atherosclerosis disease of peripheral arteries, including iliac and superficial femoral arteries. Product Description

      TAG: iliac stent mri safety


    • [PDF File] S.M.A.R.T.™ Family of Stents Brochure - Cordis

      http://5y1.org/file/27451/s-m-a-r-t-family-of-stents-brochure-cordis.pdf

      The Cordis S.M.A.R.T.™ Stent family of Nitinol Stents The S.M.A.R.T.™ Stent System has a legacy of confidence with: • More than 1 million Cordis S.M.A.R.T.™ Stents sold • Outstanding clinical evidence ... J-SMART Registry». 2011. Circulation Journal. doi: 10.1253/circj.CJ-10-1029. 3. Bunte et. al, Long-term clinical and quality of ...

      TAG: cordis smart stent mri information


    • [PDF File] Comparing the SMART Stent with the Wallstent Iliac …

      http://5y1.org/file/27451/comparing-the-smart-stent-with-the-wallstent-iliac.pdf

      SMART stent for marketing as an iliac artery stent. The study is a multi-center, randomized clinical trial com-paring the SMART stent (Cordis) and the Wallstent. There were 203 patients with chronic limb ischemia and iliac artery stenoses in the study. The indi-cation for stent placement was subop-timal angioplasty results, with subop-

      TAG: left iliac stent icd 10


    • [PDF File] Cordis S.M.A.R.T.C ONTROL - Cardinal Health

      http://5y1.org/file/27451/cordis-s-m-a-r-t-c-ontrol-cardinal-health.pdf

      Launched in 1998, the Cordis S.M.A.R.T.™ Nitinol Stent System continues to go from strength to strength. The classic ... 2007: Long SMART ™ Nitinol Stent System 120mm and 150mm (6mm-8mm diameters) Controlled Deployment 6F delivery profile (7F: 12-14mm Ø) Innovative coil construction inside

      TAG: iliac stent occlusion icd 10


    • [PDF File] S.M.A.R.T. Flex Vascular Stent System - Cordis

      http://5y1.org/file/27451/s-m-a-r-t-flex-vascular-stent-system-cordis.pdf

      S.M.A.R.T.™ Flex Vascular Stent System Product Description Stent Diameters: 9-10 mm Stent Delivery System Working Lengths: 80 cm (S suffix) and 120 cm (M suffix) Indications: common and external iliac arteries Type: Fully connected yet flexible stent design Material: Nitinol, with tantalum markers on stent ends Maximum Guidewire: 0.035"

      TAG: iliac stent icd 10


    • [PDF File] Self-Expandable Stent

      http://5y1.org/file/27451/self-expandable-stent.pdf

      販売名 : smart controlステント 承認番号 : 22500bzx00194000 クラス分類 : Ⅳ jmdnコード: 36035003/44279000 特定保険医療材料請求区分 : 血管内手術用カテーテル/末梢血管用ステントセット/一般型

      TAG: cordis stent implant card



    • [PDF File] S.M.A.R.T. Flex Vascular Stent System - Cordis

      http://5y1.org/file/27451/s-m-a-r-t-flex-vascular-stent-system-cordis.pdf

      S.M.A.R.T.™ Flex Vascular Stent System Product Description Stent Diameters: 9-10 mm Stent Delivery System Working Lengths: 80 cm (S suffix) and 120 cm (M suffix) Indications: common and external iliac arteries Type: Fully connected yet flexible stent design Material: Nitinol, with tantalum markers on stent ends Maximum Guidewire: 0.035"

      TAG: cordis smart flex biliary stent


Nearby & related entries: