Diesel fuel transfer tank pumps
[DOCX File]213116 – Diesel-Drive, Centrifugal Fire Pumps
https://info.5y1.org/diesel-fuel-transfer-tank-pumps_1_f02c95.html
SECTION 213116 - DIESEL-DRIVE, CENTRIFUGAL FIRE PUMPS. Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed. GENERAL. RELATED DOCUMENTS . Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. SUMMARY. …
[DOC File]Cummins Cal Pacific
https://info.5y1.org/diesel-fuel-transfer-tank-pumps_1_97eb5b.html
7.6.1 Designated diesel fuel transfer pumps can be utilized for this process. 7.6.2 Diesel fuel pumps must have an UL certification. 7.6.3 Diesel fuel pumps must pass KPA self-inspection before use. 7.6.4 No Diesel fuel pump will be utilized if tagged with a Lock Out Tag Out for repair. 7.6.5 Diesel fuel pump must be electrically grounded.
[DOCX File]Section 21 30 16 - DIESEL-DRIVEN, FIRE PUMPS
https://info.5y1.org/diesel-fuel-transfer-tank-pumps_1_e1096c.html
R.The elevation of the fuel tank shall be such that the inlet of the fuel supply line is located so that its opening is no lower than the level of the engine fuel transfer pump. SPEC WRITER NOTE: For projects where a Commissioning Agent is being contracted in accordance with Section 01 09 00, coordinate commissioning with Section 21 08 00.
[DOCX File]HOME - Chilli Websites
https://info.5y1.org/diesel-fuel-transfer-tank-pumps_1_8002db.html
Fill-Rite Piston Pumps have an aluminum body with a stainless steel liner. Providing smooth, continuous transfer of medium viscosity liquids, as well as oil, gasoline and diesel fuel. Pump easily mounts to a standard drum with 2" NPT threaded tank adaptor. 20 gallons per 100 strokes. Made in the USA
[DOCX File]FUEL PUMP NO - WBDG
https://info.5y1.org/diesel-fuel-transfer-tank-pumps_1_87fb0b.html
Use fuel tank level in the tank for all tests, use exterior manual testing as a last resort. DATE: ... Transfer Pumps enabled when tank [Low ][Low-Low]Sensor is exceeded. Transfer Pump starts when tank High Level Sensor is exceeded. Pumps are de-energized on no flow condition from flow switch. Manual stop de-energizes Transfer Pumps. Tank overfill valve closure upon tank high level condition ...