External pipe flow meter
[DOC File]Engineering Specification
https://info.5y1.org/external-pipe-flow-meter_1_aa9e02.html
It shall consist of a main unit and transducer set connected by up to 157m (515 feet) of dedicated cable. Transducers shall be clamped onto the outside of pipe that is filled with liquid. The flow meter shall have an internal battery that will permit the meter to operate without an external power source for a minimum of 8 continuous hours. Main ...
[DOCX File]Home | Infrastructure Planning and Facilities
https://info.5y1.org/external-pipe-flow-meter_1_3e499a.html
External adjustment. Dial: Nonreflective aluminum with permanently etched scale markings and scales in deg F. ... The location of the components of the hydronic flow meter shall comply with the straight-run pipe upstream and downstream requirements recommended by the manufacturer(s). ... If the flow meter size is smaller than line size (if ...
[DOCX File]Introduction - Flow Measurement
https://info.5y1.org/external-pipe-flow-meter_1_3ef5c3.html
‘Multi-bounce’ transducer mounting allows the meter to average out local disturbances of the flow profile over a longer axial distance on the pipe. An even number of traverses (up to 8) simply cancels all cross-flow, non-axial influences on the flow velocity measured.
[DOC File]Saturated Steam Flow Measurement Specification Vortex
https://info.5y1.org/external-pipe-flow-meter_1_869f58.html
The flow meter shall be sized by the manufacturer for each specific application and installed according to manufacturer’s recommendations. Provide a flow straightener, if required to meet the manufacturer’s minimum upstream straight pipe run requirement. Provide lateral and horizontal supports as required to minimize vibration at the meter ...
LUGB-2 Vortex Flowmeter
Flow (default 1000) When the meter outputs 4~20mA analog signal, must set the value and the value cannot be zero,the unit should be accordance with the flow unit. 5 Density setting Density setting (default 1.0) When Algorithm Selection is setting to mass flow(01,03),it must set this item,the unit is kg/m3 6 Temperature Setting Temperature Setting
[DOC File]Hersey Meter Division - Mueller Systems
https://info.5y1.org/external-pipe-flow-meter_1_88c42f.html
External Bolts. All external bolts, nuts and washers shall be of a non-ferrous material. Flanges. Flanged ends 1 1/2” and 2” meters shall be of the oval type, 3” through 6” shall be round. Threaded Ends. Meters 3/4” and 1” in size shall be Male Iron Pipe. Meters 1 1/2” and 2” shall be Internal Pipe …
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.
Hot searches
- bad credit auto loans guaranteed approval
- best english dictionary to buy
- c dictionary to list
- powershell not using environment variables
- english language teaching jobs online
- portuguese cozido recipe
- calculate price per square inch
- citation machine for pdf
- words to include on resume
- nursing ceus no test required