External pipe flow meter

    • [DOC File]Engineering Specification

      https://info.5y1.org/external-pipe-flow-meter_1_aa9e02.html

      It shall consist of a main unit and transducer set connected by up to 157m (515 feet) of dedicated cable. Transducers shall be clamped onto the outside of pipe that is filled with liquid. The flow meter shall have an internal battery that will permit the meter to operate without an external power source for a minimum of 8 continuous hours. Main ...

      portable flow meters for water


    • [DOCX File]Home | Infrastructure Planning and Facilities

      https://info.5y1.org/external-pipe-flow-meter_1_3e499a.html

      External adjustment. Dial: Nonreflective aluminum with permanently etched scale markings and scales in deg F. ... The location of the components of the hydronic flow meter shall comply with the straight-run pipe upstream and downstream requirements recommended by the manufacturer(s). ... If the flow meter size is smaller than line size (if ...

      portable flow meter


    • [DOCX File]Introduction - Flow Measurement

      https://info.5y1.org/external-pipe-flow-meter_1_3ef5c3.html

      ‘Multi-bounce’ transducer mounting allows the meter to average out local disturbances of the flow profile over a longer axial distance on the pipe. An even number of traverses (up to 8) simply cancels all cross-flow, non-axial influences on the flow velocity measured.

      portable flow meters for pipes


    • [DOC File]Saturated Steam Flow Measurement Specification Vortex

      https://info.5y1.org/external-pipe-flow-meter_1_869f58.html

      The flow meter shall be sized by the manufacturer for each specific application and installed according to manufacturer’s recommendations. Provide a flow straightener, if required to meet the manufacturer’s minimum upstream straight pipe run requirement. Provide lateral and horizontal supports as required to minimize vibration at the meter ...

      handheld flow meter


    • LUGB-2 Vortex Flowmeter

      Flow (default 1000) When the meter outputs 4~20mA analog signal, must set the value and the value cannot be zero,the unit should be accordance with the flow unit. 5 Density setting Density setting (default 1.0) When Algorithm Selection is setting to mass flow(01,03),it must set this item,the unit is kg/m3 6 Temperature Setting Temperature Setting

      flow gpm for pipe size


    • [DOC File]Hersey Meter Division - Mueller Systems

      https://info.5y1.org/external-pipe-flow-meter_1_88c42f.html

      External Bolts. All external bolts, nuts and washers shall be of a non-ferrous material. Flanges. Flanged ends 1 1/2” and 2” meters shall be of the oval type, 3” through 6” shall be round. Threaded Ends. Meters 3/4” and 1” in size shall be Male Iron Pipe. Meters 1 1/2” and 2” shall be Internal Pipe …