Y N Automatic stop functions properly Y N Test data and flow charts completed (attach all water-flow charts, electrical power charts, performance curves, etc.) Y N Automatic start: psi (bar) Automatic stop: psi (bar) Fire pump electrical readings recorded at each flow condition?
[DOCX File]Section 21 30 16 - DIESEL-DRIVEN, FIRE PUMPS
https://info.5y1.org/fire-pump-flow-test-graph_1_e1096c.html
The graph included on the Centrifugal Fire Pump Acceptance Test Form shall be annotated to show 1) the water supply available, 2) the manufacturer’s certified pump curve, 3) the acceptance test curve, and 4) a curve showing the water supply and acceptance test curve combined.
[DOCX File]Section 21 30 13 - ELECTRIC-DRIVEN, FIRE PUMPS
https://info.5y1.org/fire-pump-flow-test-graph_1_070c96.html
The graph included on the Centrifugal Fire Pump Acceptance Test Form shall be annotated to show 1) the water supply available, 2) the manufacturer’s certified pump curve, 3) the acceptance test curve, and 4) a curve showing the water supply and acceptance test curve combined.
[DOC File]Mike Slusher’s Pump Test
https://info.5y1.org/fire-pump-flow-test-graph_1_629e00.html
This test is to be used annually to test fire apparatus that has a fire pump with 250 gpm or larger capacity or if the pump and/or engine on the apparatus have been repaired or modified. It meets the NFPA 1901 Class A Pump rating test and ISO requirements for annual pump or service test.
[DOC File]Pumping Apparatus Driver Operator (1st Edition)-Chapter 16 ...
https://info.5y1.org/fire-pump-flow-test-graph_1_3e9fcb.html
The objective of a flow test is to establish quantity (gallons or liters per minute) and pressures available at a specific location on a particular water supply system. Manufacturer Test Fire pump or aerial device test performed by the manufacturer prior to delivery of the apparatus. Preservice Test Test performed on fire pumps or aerial
Medium and High-Expansion Foam Systems - NFPA
Fire Pumps Fire Pumps Annual Performance Tests. Inspector: System: Location: Date: Y = Satisfactory N = Unsatisfactory (explain below) Pump manufacturer and model: Type: Centrifugal Turbine Controller manufacturer and model: Rated capacity: gpm (L/min) Water supply source: Rated pressure: psi (bar) Rated speed: rpm Power: Electric Diesel Steam Automatic starts performed 6 times Y N Timer ...