https://info.5y1.org/ge-surge-protector-10-2_1_534209.html
PERIMETER TECHNOLOGIES, INC., subject to the terms and conditions contained herein, hereby warrants that it will repair or replace for the lifetime of the product, at its discretion any Pet Stop Smart Receiver© that proves defective by reason of workmanship and/or material for which the unit was purchased and further, for the life thereof will ...
[DOC File]Volume 17, Number 2
https://info.5y1.org/ge-surge-protector-10-2_1_652944.html
With crystals at $10 per pair, it cost $120 (about $350 today) to fill all 12 channels in a 2 meter radio. It was possible to equip your radio with the repeaters and simplex frequencies used in one area, then find all of your channels were useless 200 miles away.
[DOCX File]05 56 00
https://info.5y1.org/ge-surge-protector-10-2_1_b7ceaa.html
Integral "fine" surge suppression shall be incorporated into the power supply Power supplies shall conform to CE electromagnetic compatibility as described in EN61000-6-2 and EN 50081-2. Power supplies shall have means of limiting DC current in case of short circuit or an overload and shall automatically reset themselves when the fault is ...
[DOC File]PUBLIC NOTICE - Federal Communications Commission
https://info.5y1.org/ge-surge-protector-10-2_1_b51ca5.html
ge (hac) (vc) (t) 2-9450(xxxx) "d" version . 810-cx-2000. notice of change not affecting compliance. has been filed for the following ... external telephone tip/ring surge protector. equipment description: external protection for loop start interfaces. trade name model other reg. affected . apc corp cns7t10, cns7t6 ...
[DOCX File]IECEx
https://info.5y1.org/ge-surge-protector-10-2_1_53585d.html
The surge protection device shall be capable of diverting a minimum peak discharge current of 10 kA (8/20 μs impulse according to IEC 60060-1 for 10 operations). Such device obviously can not be installed in zone 0. Surge protection devices can be considered as simple apparatus to …
TRANSIENT OVERVOLTAGE PROTECTION SEMINAR
Transient Voltage Suppression Manual, Chapter 2, p. 15, General Electric Company, Auburn, NY (1978). 11. F.D. Martzloff, “Coordination of Surge Protectors in Low-Voltage AC Power Circuits,” Preprint No. F29 635-4 for IEEE PES Summer Meeting, Vancouver, Canada (July 1979).
Last updated March 2004 - NIST
[13] F. A. Fisher, Personal communication and acknowledgment, (General Electric Corporate R&D) designed the test generator and performed in the seventies the experiment that produced the oscillograms of Fig. 2, which were incorporated in the GE Transient Suppression Manual [4].
[DOCX File]ევროპულ კვალიფიკაციათა ჩარჩოს
https://info.5y1.org/ge-surge-protector-10-2_1_78df46.html
მოდულის განხორციელება ძირითადად შესაძლებელია კომპიუტერებით ...
[DOC File]MINUTES OF THE BOARD OF SELECTMEN
https://info.5y1.org/ge-surge-protector-10-2_1_434b4d.html
Oct 04, 2005 · Tax Abatement for GE Capital Modular Space – ... surge protector, and something to set the equipment up on (computer desk). Selectperson Hakala mentioned they should make a trip to the State surplus in Augusta to see what they might have for …
[DOCX File]SM SDM Valero Memphis - Salvex
https://info.5y1.org/ge-surge-protector-10-2_1_df8dcb.html
Certified to fulfill the requirements of SIL3 safety equipment as defined in the following documents: IEC61508, IEC60664-3, EN50156, EN54-2, EN50178, IEC60068, IEC61131-2, IEC61131-3, …