Genesis stent mri compatibility

    • [PDF File]Resolute Onyx™ Zotarolimus-Eluting Coronary Stent System Rapid Exchange ...

      https://info.5y1.org/genesis-stent-mri-compatibility_1_c047ba.html

      5.7 MAGNETIC RESONANCE IMAGING (MRI) SAFETY INFORMATION ... The Resolute Onyx™ stent is comprised of a bare metal stent with a Parylene C primer coat and a coating that consists of a blend of the drug zotarolimus and the BioLinx® polymer system. BioLinx® is a blend of the Medtronic proprietary components C10 and C19, and PVP


    • [PDF File]MULTI-LINK VISION 2.75 mm Coronary Stent Systems Information for ...

      https://info.5y1.org/genesis-stent-mri-compatibility_1_d7c100.html

      When crossing a newly deployed stent with a guide wire, balloon or delivery system, exercise care to avoid disrupting the stent geometry. 5.4.1 MRI Statement The MULTI-LINK VISION Coronary Stent has been shown in non-clinical testing to be MRI safe immediately following implantation. MRI test conditions used to evaluate this stent were: for


    • [PDF File]Contraindications to magnetic resonance imaging

      https://info.5y1.org/genesis-stent-mri-compatibility_1_4d1aa3.html

      Magnetic resonance imaging (MRI) is a method that has evolved continuously during the past 20 years, yielding MR systems with stronger static magnetic fields, faster and stronger gradient magnetic fields, and more powerful radiofrequency transmission coils. It is increasingly being used and requested as several new indications have been


    • [PDF File]How to Determine the MRI Safety and Compatibility of an Implant ... - AAPM

      https://info.5y1.org/genesis-stent-mri-compatibility_1_2e14c4.html

      MRI safety and compatibility of an implant or a medical device. Conclusion How to Determine the MRI Safety and Compatibility of an Implant or a Medical Device? ... 2013. Journal of magnetic resonance imaging : JMRI. 2013;37(3):501–530. (2) Kanal E, Shellock FG, Talagala L. Safety considerations in MR imaging. Radiology. 1990;176(3):593–606.


    • [PDF File]MRI Compatibility for PI Products - US - Boston Scientific

      https://info.5y1.org/genesis-stent-mri-compatibility_1_6a5ebb.html

      MAGNETIC RESONANCE IMAGING (MRI) SAFETY INFORMATION Non‐clinical testing has demonstrated that WALLSTENT Tracheobronchial is MR Conditional for single and overlapping lengths up to 120 mm. A patient with this stent can be scanned safely, immediately after placement, under the following conditions:


    • [PDF File]English PALMAZ GENESIS 0086 - University of Pittsburgh

      https://info.5y1.org/genesis-stent-mri-compatibility_1_be737a.html

      The PALMAZ GENESIS Peripheral Stent is a balloon-expandable, laser cut stent made from 316L stainless steel tubing. The stent is supplied in two nominal lengths: 29 mm and 39 mm. Specific expansion ranges for each stent length are shown in Table 1. The PALMAZ GENESIS Peripheral Stent is sold unmounted for use with all catheter lengths of the ...


    • [PDF File]Express LD and SD MRI Information - Boston Scientific

      https://info.5y1.org/genesis-stent-mri-compatibility_1_e1f273.html

      Renal Stent should not migrate in this MR environment. MR imaging at 3 T or less may be performed immediately following the implantation of the Express SD Renal Stent. In this testing, the stent experienced a maximum temperature rise of 0.96 ºC at a maximum whole body


    • [PDF File]Guidant MULTI-LINK PENTA Coronary Stent Systems - U.S.

      https://info.5y1.org/genesis-stent-mri-compatibility_1_d54fd5.html

      x The Guidant MULTI-LINK PENTA Coronary Stent has been shown in non-clinical testing to be MRI safe immediately following implantation. MRI test conditions used to evaluate this stent were: for magnetic field interactions, a static magnetic field strength of 3 tesla with a maximum spatial gradient magnetic field of 3.3 tesla/meter; for MRI-


    • [PDF File]MRI Information - Boston Scientific

      https://info.5y1.org/genesis-stent-mri-compatibility_1_626365.html

      UroLume™ Endoprosthetic Stent AMS Mainstay™ Urologic Soft Tissue Anchor AMS Men's Health Company Contact: Rich Broda, AMS Men's Health Patient Liaison, at 800-328-3881 extension 6261, or 952-930-6261, or Email at Patient.Liaison@bsci.com, ... Magnetic Resonance Imaging (MRI) Important Safety Information ...


    • [PDF File]Cordis PaLMaz Blue - Cardinal Health

      https://info.5y1.org/genesis-stent-mri-compatibility_1_13290a.html

      5F CSI / 6F GC compatibility for all sizes 4-7mm diameter L605 allows for thinner wall design mR SaFETY ... Genesis™ Heritage The Gold Standard The PaLMaz® Blue™ .018 incorporates the proven design of the PaLMaz® and PaLMaz® Genesis™ balloon-expandable stent family: Closed Cell Design for optimal scaffolding One Piece Laser Cut Tube no ...


    • [PDF File]Brain Stents - Michigan Medicine

      https://info.5y1.org/genesis-stent-mri-compatibility_1_607b2a.html

      When a stent is first positioned at the base of the aneurysm, it can act as a kind of “backstop”. The coils are then fed through the mesh and into the aneurysm. In this way the stent secures the coils, making sure they stay in place. Using this “backstop” technique makes it possible to treat aneurysms that were often untreatable in the ...


    • [PDF File]Pre-mounted PALMAZ GENESIS Stent - Cardinal Health

      https://info.5y1.org/genesis-stent-mri-compatibility_1_7c2a42.html

      The PALMAZ® GENESIS ™ Stent on OPTA Pro can be used with other Cordis product family. the products listed hereunder are only a selection. Please contact your local sales representative for further information on product compatibilities. Cannula usable length Catalogue Number Catalogue Number Catalogue Number (cm) 6F 8F7F


    • [PDF File]Magnetic Resonance Imaging (MRI) COMPATIBILITY Coloplast’s penile ...

      https://info.5y1.org/genesis-stent-mri-compatibility_1_4d8c3b.html

      All Genesis, Acu-Form®, and Malleable penile prostheses are MR conditional per testing commissioned by Coloplast and undertaken by F. Shellock in July 2007. All Titan, Alpha I, Excel, and Mark II materials are MR conditional per testing commissioned by Coloplast and undertaken by F. Shellock in December 2005 and February 2011 (OTR/Touch).


    • [PDF File]PALMAZ GENESIS on OPTA Pro Stent - Cardinal Health

      https://info.5y1.org/genesis-stent-mri-compatibility_1_cb9d4b.html

      diameter x length Stent Length Stent Length Compatibility Compatibility Length of Delivery System (mm x mm) (mm)(F)8F / .088" (mm)80 cm 135 cm 4 x 20 18 17 6 8 PG1840PPS 4 x 25 24 23 6 8 ... The PALMAZ GENESIS™ on OPTA™ Pro Stent can be used with other Cordis product family. The products listed hereunder are only a selection.


    • [PDF File]Vascular Stent System - BD

      https://info.5y1.org/genesis-stent-mri-compatibility_1_e1b72e.html

      • Once the stent is partially or fully deployed, micro- adjustments are no longer possible and the stent should not be dragged or repositioned in the lumen. • Once stent deployment has been initiated, the stent cannot be recaptured using the stent delivery system. 7.0“pin PRECAUTIONS This device is intended for use only by physicians who


    • [PDF File]Instructions for Use Cordis S.M.A.R.T.0 CONTROLS Vascular Stent System ...

      https://info.5y1.org/genesis-stent-mri-compatibility_1_23a57f.html

      expanding stent is composed of a nickel titanium alloy (nitinol). A total of 12 (6 at each end) tantalum radiopaque markers are located on the ends of the stent. The stent is a flexible, fine mesh tubular prosthesis that expands upon deployment to appose the vessel wall. Upon deployment, the stent imparts an outward radial force on the


    • [PDF File]MRI-Ready Systems Manual - Abbott

      https://info.5y1.org/genesis-stent-mri-compatibility_1_13b64e.html

      Each lead needs to be checked for MRI compatibility and individual scan parameters. The device/lead combination tables list the MR Conditional lead lengths (page 3). 3 St. Jude Medical MR Conditional Systems Device/Lead Combinations Pacemakers Table 3. St. Jude Medical MR Conditional System device/lead combinations for Accent MRI™ pacemakers


    • [PDF File]Understanding Your Cerebral Aneurysm, - UCSF Radiology

      https://info.5y1.org/genesis-stent-mri-compatibility_1_a09ca1.html

      Stent – A specially designed, expandable metal tube that is inserted into a vessel. A stent acts as a scaffold to provide structure for a vessel. In a wide neck aneurysm, a stent is placed across the opening or neck of the aneurysm to secure the placement of coils and to maintain blood flow through the artery in which the stent is placed.


    • [PDF File]Guidelines for the Management of Patients with Coronary Artery Stents ...

      https://info.5y1.org/genesis-stent-mri-compatibility_1_dbd704.html

      (9) Jehl J, et al. Clinical safety of cardiac magnetic resonance imaging at 3 T early after stent placement for acute myocardial infarction. Eur Radiol 2009;19:2913-8. (10) Kaya MG, et al. Long-term clinical effects of magnetic resonance imaging in patients with coronary artery stent implantation. Coron Artery Dis 2009; 20:138-42.