Gpm per btu hydronic system

    • [DOCX File]Michigan State University

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_22cffe.html

      Testing, adjusting and balancing of air and hydronic system fluid flow rates at the system and distribution system level to the indicated quantities according to tolerances specified herein. The following systems to be included: Air Systems: Constant-volume air systems. Variable-air-volume systems. Multizone systems. Induction-unit systems.


    • [DOCX File]Section 23 05 93 - TESTING, ADJUSTING, AND BALANCING …

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_b90ab8.html

      //Coordinate TAB, including system volumetric controls, with Section 23 09 23, DIRECT-DIGITAL CONTROL SYSTEM FOR HVAC.// Section 23 36 00, AIR TERMINAL UNITS, specifies that maximum and minimum flow rates for air terminal units (ATU) be factory set.


    • SECTION 235216 - CONDENSING BOILERS

      C.Pressure Drop Curve. Submit pressure drop curve for the following flow ranges per designated capacities below. 750-1000 MBH: 12-175 GPM. 1500-2000 MBH: 25-350 GPM. 2500-3000 MBH: 25-400 GPM. 4000 – 5000N MBH: 35 - 500 GPM. 5000-6000 MBH: 75-600 GPM. D.Shop Drawings: For boilers, boiler trim and accessories include:


    • SECTION 230593 - TESTING, ADJUSTING, AND BALANCING …

      Other system operating conditions that affect performance. System Diagrams: Include schematic layouts of air and hydronic distribution systems. Present each system with single-line diagram and include the following: Quantities of outdoor, supply, return, and exhaust airflows including system total airflow rates. Water and steam flow rates.


    • [DOCX File]PART 1 - Thermal Solutions Products LLC

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_270360.html

      The control system shall be fully integrated into the boiler control cabinet and incorporate single and multiple boiler control logic, inputs, outputs and communication interfaces. The control system shall coordinate the operation of up to eight (8) fully modulating …


    • [DOCX File]Section 15050

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_549e31.html

      See also sections 32 17 43 26 (Electric) and 32 17 43 60 (Hydronic) Pavement Snow Melting Systems. When the snowmelt system is in operation the system shall include a …


    • SECTION 235216 - CONDENSING BOILERS

      C.Pressure Drop Curve. Submit pressure drop curve for the following flow ranges per designated capacities below. 750 - 1000 MBH: 12 - 175 GPM. 1500 - 2000 MBH: 25 - 350 GPM. 2500 - 3000 MBH: 25 - 400 GPM. 4000 – 5000N MBH: 35 - 500 GPM. 5000 - 6000 MBH: 75 - 600 GPM. D.Shop Drawings: For boilers, boiler trim and accessories include:


    • [DOCX File]Section 230500 - Modular Central Plant

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_d2f7b4.html

      System shall be Large Missile Impact tested and approved by Miami-Dade per the following tests: TAS 201-94, 202-94, 203-94. Doors All egress doors shall be equipped with emergency door opening hardware and emergency lights, with signage indicating egress


    • [DOC File]STATEMENT OF WORK - Green-Simmons

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_ce15fa.html

      Submit pressure drop curve for flows ranging from 0 gpm to 375 gpm for the 2.0 MBTU boiler. If submitted material is different from that of the design basis, boiler manufacture shall incur all costs associated with reselection of necessary pumps.


    • [DOCX File]SECTION 238318 – SNOW-MELTING SYSTEM

      https://info.5y1.org/gpm-per-btu-hydronic-system_1_666288.html

      System shall be of hydronic type, field-assembled or packaged, skid mounted unit, except for distribution piping. System shall consist of glycol heater unit, circulating pump, expansion tank, air separator, temperature and pressure gauges, balancing valve, valves and fittings, chemical treatment, supply and return main, manifolds and fittings, distribution loops, and controls.