Heating load calculation spreadsheet
[DOC File]Load Balance & Score Card Workpaper - SoCalGas
https://info.5y1.org/heating-load-calculation-spreadsheet_1_53e5d8.html
Aug 01, 2006 · The methodology for the Load Balance Tool allows users to exclude specific pieces of gas equipment from the adjusted load calculation. For example, if a piece of equipment is known to operate a specific number of hours in a year, the load factor for this equipment can be omitted from the adjustment calculation shown in Equation 1.
[DOC File]Equipment Load Factors, Use Factors and Diversity Factors ...
https://info.5y1.org/heating-load-calculation-spreadsheet_1_d5af97.html
To do a good job on an energy audit, the energy auditor must understand the areas of equipment load factor, use factor and diversity factor. Definitions: First, let's define these terms. Load factor - the ratio of the load that a piece of equipment actually draws when it is in operation to the load it could draw (which we call full load).
[DOC File]Furnace Energy Efficiency - SoCalGas
https://info.5y1.org/heating-load-calculation-spreadsheet_1_9d3c17.html
The calculation steps corresponding to the line numbers on the table are described below. Equipment Load and Annual Use Calculation – Information from this section is to be taken from the Load Balance Tool. Customer supplied information that varies from the Load Balance Tool requires approval.
[DOC File]Water Heater Replacement in the Weatherization Assistance ...
https://info.5y1.org/heating-load-calculation-spreadsheet_1_27c922.html
The heating/cooling effect, Qreject/in, from a HPWH is 3,500 Btu/h (the rating of a typical HPWH compressor) when the compressor is operating. To estimate the hours of operation of the compressor, two things must be known: The water-heating load . The relationship between HPWH compressor run-time and the amount of hot water generated
[DOCX File]Summary of - PUC
https://info.5y1.org/heating-load-calculation-spreadsheet_1_1acddb.html
I conservatively assume a 100% load factor for water heating (Staff’s calculation assumes 53%), but I think this is reasonable for this particular evaluation and obviates the need to make a separate estimate of demand savings from the measure.
[DOCX File]Summary .gov
https://info.5y1.org/heating-load-calculation-spreadsheet_1_9e05c1.html
PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA. Agenda ID: 18930 ENERGY DIVISION. RESOLUTION . E-5. 073. December 3, 2020. RESOLUTION. Resolution E-5073. Approving with modifications Pacific Gas and Electric Company’s Advice Letter 5731-E to implement the WatterSaver program to enable shifting of electric water heating load in compliance with Assembly …
[DOC File]July 6, 2005
https://info.5y1.org/heating-load-calculation-spreadsheet_1_861638.html
The calculation method used in IndoorPoolCalc is summarized below. Also, refer to a discussion of the calculation method (the “Shah method”) in the article at: ... stick with the “energy demand” on the “Solar Resource & Heating Load” sheet. IndoorPoolCalc: Calculation Background ... Comments on the spreadsheet and calculation method ...
[DOCX File]LCLS-II Cryogenic Heat Load - INDICO-FNAL (Indico)
https://info.5y1.org/heating-load-calculation-spreadsheet_1_eb274f.html
The major dynamic heat uncertainty is Q0 = 2.7E10, which originated from a back-calculation for an 18 kW total 4.5 K-equivalent cryogenic plant based on preliminary heat load estimates in November, 2013. Removing cavity dynamic heat consumes approximately 2/3 of total cryogenic power.
[DOC File]FORMULA SHEET - Homestead
https://info.5y1.org/heating-load-calculation-spreadsheet_1_691754.html
Calculation of Velocity and Volumes 1. A single duct/ single zone A/C roof top unit is supplying air to the conditioned space by way of a 24” by 12” supply duct. Calculate the air velocity as well as the volume (CFM). A pitot tube manometer reads 0.06 inches water column. Area = L x W ÷ 144 = 24 x 12 ÷ 144 = 2 SQ Feet CFM= Area (SQ.
[DOC File]California State University, Northridge
https://info.5y1.org/heating-load-calculation-spreadsheet_1_1805f7.html
Since the heating load is an input to the problem, a small load can produce values of X and Y that will lead to a value of f that is greater than one. This is outside the range for which the f-chart equations are valid. The water heating demand for the summer months is in the range of 11- 14 therms.
Nearby & related entries:
To fulfill the demand for quickly locating and searching documents.
It is intelligent file search solution for home and business.