BaBar LST High Voltage Power Supply . GUI User’s Instructions. Draft version 1.0. March 25th 2004. This document is meant as a quick reference to enable LST collaborators to use the OSU HV power supply test graphical user interface.
[DOCX File]High/Low Voltage Disconnect Test Procedure
https://info.5y1.org/high-voltage-variable-power-supply_1_53f40d.html
To perform an open circuit test, the high voltage (primary) side of the transformer is energized by connecting it to the variable voltage supply terminals as shown in the circuit of Figure 5. In order to obtain open circuit test data, adjust the variable AC voltage supply to its zero voltage position before turning on the AC power switch.
[DOC File]EE 448 - Iowa State University
https://info.5y1.org/high-voltage-variable-power-supply_1_bf0d2b.html
Small variable-voltage power supply units. A characteristic use of autotransformers is illustrated by the following example. In the past, 600 V systems were common within certain industries. The conversion to 480 V could be accomplished by the use of a standard 480 to 120 V transformer.
[DOC File]EE 442 - Iowa State University
https://info.5y1.org/high-voltage-variable-power-supply_1_d2ccc7.html
b) Turn on the power supply and adjust the dc motor rheostat for a motor speed of 1800 r/min. c) Adjust the dc excitation of the alternator until the voltage across the 600( load E1 = 208 . Vac. Measure and record the two other phase voltages E2 and E3. d) Turn off the power supply without touching any of the variable controls.
[DOCX File]1.01 - Power management solutions | Eaton
https://info.5y1.org/high-voltage-variable-power-supply_1_3cf33e.html
Step 4: Adjust the output of power supply two to 6.2V, slowly increase it by hundredths of a volt until the battery is disconnected from the circuit. Record the voltage. Step 5: Adjust the output of power supply two to 5.8V, slowly decrease it by hundredths of a volt until the USB output and fan output are disconnected.
[DOC File]BaBar LST High Voltage Power Supply
https://info.5y1.org/high-voltage-variable-power-supply_1_d262db.html
Energy Saver (ESS) Feature: The UPS shall continuously monitor the voltage and frequency of the bypass source. When the source parameters are within acceptable limits, the UPS will utilize a minimal/optimal combination of its internal subsystems to ensure acceptable power is always delivered to the critical load, at a system efficiency of 99% or greater, over the range of 10% to 100% load.
[DOC File]IEEE Standards - draft standard template
https://info.5y1.org/high-voltage-variable-power-supply_1_0b7bc8.html
Return the voltage to zero and turn off the power supply. Couple the dynamometer to the dc motor/generator with the timing belt. Set the dynamometer control knob at its full mid range position (to provide a starting load for the motor). Turn on the power supply and adjust the variable …