Table 4.3 - Valve-bit assignment. bit 12 11 10 9 8 7 6 5 4 3 2 1 0 Valve V20b V20a V5 V’4 V4 V3b V2b V’1b V1b V3a V2a V’1a V1a Writing a “1” will enable the connection (close of the corresponding switch). The UGBS board will not execute a USCM open command performed on a valve whose corresponding enable bit is set to 0.
[DOCX File]PART 1
https://info.5y1.org/honeywell-3-way-mixing-valve_1_abfce0.html
In order to prevent low inlet water temperature, provide an electric actuated three-way mixing valve with a 4-20 mAdc input control signal and slow (1 minute) travel time for each boiler. If the boiler inlet water temperature is below 130° F (adjustable) or when boiler differential temperature is above 40° F (adjustable), the valve shall ...
[DOCX File]PICV Div 23 Guide Specification - Honeywell
https://info.5y1.org/honeywell-3-way-mixing-valve_1_6baaaf.html
Valves shall be Honeywell. The 2-way valves shall have EPDM O-rings behind ball seals to allow for a minimum close-off pressure of 100 psi with actuator which provides 35 lb-in. torque for 1/2 to 3 in. sizes. Valve shall be available with a minimum of 53 unique CV values. Valve shall be available with threaded (fNPT) end connections. The 3-way ...
[DOC File]TERMS &CODITIONS FOR CAMC OF DDC SYSTEMS
https://info.5y1.org/honeywell-3-way-mixing-valve_1_629839.html
Three-way mixing valves operation must be verified by giving simulated voltages. Chain calibration of three-way mixing valve actuators also shall be carried out. Chain calibration of temperature, RH, level, differential pressure and flow sensors/transmitters.
[DOCX File]23 0901
https://info.5y1.org/honeywell-3-way-mixing-valve_1_83be2a.html
Size three (3) way mixing or diverting valves not directly associated with pump sub-circuit for 3 psi to 5 psi pressure drop. Sub-circuit is defined as branch supply and return piping to terminal device, including valve, coil, control valve, and balancing valve.
[DOCX File]Honeywell Building Controls Commercial HVAC Solutions
https://info.5y1.org/honeywell-3-way-mixing-valve_1_d52aa5.html
Pressure-dependent dual duct without flow mixing. Variable air volume with return flow tracking. Economizer with differential enthalpy. Minimum airflow coordinated with CO2. Unit ventilator cycle (1, 2, 3) 2-pipe. Unit ventilator cycle (1, 2, 3) 2-pipe with face/bypass. Unit ventilator cycle (1, 2, 3) 4-pipe.