Honeywell 3 way valve body

    • [PDF File]SMALL LINEAR VALVES PN16 FOR MODULATING AND ON ... - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_caceb4.html

      Fig. 2. Three-way valve operation Three-Way Valves with Bypass These valves simplify the installation, which is depending on the layout of the pipework, as the bypass pipe is part of the valve. The information for the normal three-way valves is also valid for this type. AB A B inlet +-AB A B inlet +-Fig. 3. Three-way valve with bypass


    • [PDF File]Specification Data For VBN Threaded Control ... - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_b5b63a.html

      Valve Type: Control Ball Valve Body Pattern: 2-way, 3-way Connection Type: Female NPT Controlled Fluid: Chilled or hot water with up to 50% Gly-col. Not for use with steam or fuels. Leakage Rating: ANSI Class IV (0.01% of CV maximum) for 3-way A port and ANSI Class III seat leakage specifi-cation (0.1% of CV) for 3-way B port Maximum Safe ...


    • [PDF File]V4044C, V4044F Motorized Zone Valves

      https://info.5y1.org/honeywell-3-way-valve-body_1_42747b.html

      Honeywell V4044C and F 3-port hydronic valves are used in domestic and small commercial heating and cooling applica-tions to control the flow of hot or cold water. ... V4044F 3-way zone valve Body kvs-value max. close-off pressure Dimensions R L C H 1/2” BSPP (internal) 3.0 1.4bar 1/2” 96 46 128


    • [PDF File]V5329A,C - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_3af636.html

      v5329a,c flanged linear valve pn6/16 – product data en0b-0703ge51 r0217 2 sizes and flow capacities order number valve size kvs v5329a1004 dn15 2.5 v5329a1012 dn15 4.0 v5329a1020 dn20 6.3 v5329a1038 dn25 10.0 v5329a1046 dn32 16.0 v5329a1053 dn40 25.0 v5329a1061 dn50 40.0 v5329a1079 dn65 63.0 v5329a1087 dn80 100.0 v5329c1000 dn15 2.5


    • [PDF File]VC7900 SERIES MODULATING CONTROL VALVES - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_4c4a6a.html

      1.If the valve is leaking, drain system OR isolate valve from the system. Do not remove valve body from plumbing. 2.Check to see if the cartridge needs to be replaced. 3.If the motor or other internal part of the actuator is damaged, replace the entire actuator assembly. NOTE: Honeywell hydronic valves are designed and tested for silent


    • [PDF File]3-Way, Balanced Valves / Valvole a 3 vie Bilanciate ...

      https://info.5y1.org/honeywell-3-way-valve-body_1_0cbaec.html

      3-Way, Balanced Valves / Valvole a 3 vie Bilanciate / Válvulas de 3 vías, equilibradas APPLICATION The VC series 2-position hydronic valves are used in domestic and small commercial applications to control the flow of hot and/or cold water or glycol solution up to 50% concentration. They consist of an actuator, valve and a


    • [PDF File]77-5316 - V5013B-F Three-Way Mixing & Diverting Valves

      https://info.5y1.org/honeywell-3-way-valve-body_1_645626.html

      Fig. 2. V5013B-E Flanged Body Dimensions. Fig. 3. V5013F Screwed Body Dimensions. C A B 1 1 ACTUATOR BASE 3-1/2 INCHES (89 MM) WITH STEM DOWN 1-3/8 IN. (35 MM) BONNET SIZE C7961 A B A B IN OUT IN TO CONTROLLER MIXING VALVE STEM UP INCREASES B TO AB FLOW C7960 Fig. 4. V5013B, D, and F Flow Diagram. A A B OUT IN B OUT TO CONTROLLER DIVERTING ...



    • [PDF File]Honeywell 3W Globe Valve

      https://info.5y1.org/honeywell-3-way-valve-body_1_40c0b1.html

      3. Mount the valve with the flow arrow pointed in the direction of flow through the valve. 4. Mount the valve between aligned pipes. Mounting the valve on pipes that are not aligned causes leakage at the valve to pipe connection. 5. Ensure complete engagement on pipe to valve body threads. 6. Hold the valve body with a clamp or pipe wrench on the


    • [PDF File]63-2648—02 - VBN2, VBN3 Control Ball Valves With Threaded ...

      https://info.5y1.org/honeywell-3-way-valve-body_1_359c65.html

      VBN2, VBN3 CONTROL BALL VALVES WITH THREADED CONNECTIONS 3 63-2648—02 Table 2. VBN3 Three-way valve Cv Ratings. a Denotes full A-port (with no insert). Provides linear flow control. b B port C v is 20% less for constant combined flow through coil and bypass. See Fig. 4.Multiply the Cv value by 0.865 to get the capacity in kvs, if S.I. (metric) units are required.


    • [PDF File]MU1H-2806GE25 R0107 3-Wege Zonenventile

      https://info.5y1.org/honeywell-3-way-valve-body_1_82a292.html

      This valve should be serviced by a trained, experi-enced service technician. 1. If the valve is leaking, drain system OR isolate valve from the system. Do not remove body from plum-bing. 2. Check to see if the cartridge needs to be replaced. 3. If the motor or other internal parts of the actuator is damaged, replace the entire actuator assembly


    • [PDF File]Control Valve Products - Honeywell Process

      https://info.5y1.org/honeywell-3-way-valve-body_1_2952c5.html

      Series 9130 Mixing / Diverting Seated 3-Way Valves ANSI 150 - 600 / JIS 10K-40K DIN/BS 4504 PN10-PN40 Series 9210 High Performance Butterfly Valves Series 9130 Mixing / Diverting Seated 3-way Valves General Three-way type control valves are used for controlling the fluids mutually to three directional pipings, i.e., mixing service and diverting ...


    • [PDF File]V5050A 3-WAY FLANGED LINEAR VALVE PN16 - Honeywell India

      https://info.5y1.org/honeywell-3-way-valve-body_1_bc9475.html

      Valve type 3-way mixing Rangeability 50:1 Leakage rate ≤0.1 % of kVS port A-AB ≤1 % of kVS port B-AB Stroke 38 mm Valve body End connections Flanged per ISO 7005-2 Material Cast iron (GG25) Technical Speciļ¬cation Dimensions See Fig. 1 Seat Body integrated Stem Stainless steel Plug Stainless steel, skirt guided


    • [PDF File]Series 9130 3-Way Globe Valve - Honeywell Process

      https://info.5y1.org/honeywell-3-way-valve-body_1_ae09a2.html

      A) The 3-way globe valve has been designed for the requirements and applications of piping. As flow rate is effectively controlled, it has less cavitation, noise, corrosion, or vibration relatively. B) The most important feature of the Honeywell 3-way globe valve is its body that has been


    • [PDF File]V5013B,C,F Three-Way Mixing and Diverting Valves - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_0d0e6f.html

      3 3 Fig. 9. Mounting of threaded valve bodies. Flanged Valve Bodies The valve flanges are flat faced with a smooth finish. Companion flanges must be of the same specifications. Mounting bolts must be long enough to allow nuts to utilize the full length of the nut threads. The bolts should be approximately 1/8 in. (3 mm) smaller than


    • [PDF File]VC Series Zone Valves - Honeywell Home

      https://info.5y1.org/honeywell-3-way-valve-body_1_c153ee.html

      Honeywell VC Series balanced 2-position hydronic valves are used in domestic and small commercial heating and cooling ... Body 2-way VC valve 3-way VC valve C kvs-value C D kvs-value 15mm compression 98 3.4 98 136 4.3 22mm compression* 112 6.8 112 140 8.6 28mm compression* 112 7.7 112 140 8.6 ...


    • [PDF File]VC7900 Series

      https://info.5y1.org/honeywell-3-way-valve-body_1_91729d.html

      The VC hydronic valve consists of a valve body and replaceable characterized cartridge assembly. When used with a Honeywell VC7900 actuator, the valve provides proportional flow in modulating, diverting or mixing applications. They are designed to provide sinusoidal valve actuator travel, and therefore operate silently and resist water hammer.


    • [PDF File]Field Devices - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_03afbe.html

      Honeywell A5005 A5039 A5054 C5001 C5019 C5027 C5068 C5076 C5084 C5142 C5159 ... (valve stem, plug, body gasket, rivet or locking nut) kvs 25 K43298806001 kvs 40 K43298817001 ... 3-way valve inserts kvs value DN Order-Number 0.25 15 0902821 0.40 15 0902822 0.63 15 0902823


    • [PDF File]V5852A/V5853A/V5862A/V5863A Small Linear Valves

      https://info.5y1.org/honeywell-3-way-valve-body_1_ad9901.html

      The valve body should be completely installed in the pipe line before the actuator is installed. 1. Verify pipe size and flow direction for the valve being used. 2. Position the valve so that the actuator can be easily installed. 3. Install the valve using the applicable tools and supplies (wrenches, solder, flux, torch or soldering iron). Follow


    • [PDF File]VBF2, VBF3 Control Ball Valves with Flanged ... - Honeywell

      https://info.5y1.org/honeywell-3-way-valve-body_1_7107ea.html

      3. For horizontal piping, install the valve so the actuator is above the valve body. Install the valve in any position between vertical and horizontal. Do not install the valve with the stem below horizontal or upside down. For vertical piping, the actuator can be mounted in any orientation. 4. Hoist valve by its body only. Do not lift by stem ...


Nearby & related entries: